FieldServer FS-RA-CLX-BAS instruction manual SlotServer Data Transfer over IO Data Image

Page 24

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011)

Page 24 of 34

SlotServer Data Transfer over IO Data Image

Logix CPU

External Device

eg. LonWorks

Input Data Image

Controller Tag

SlotServer

Input Data

In [0]

Modbus Metasys

Local:Slot:I:Data

Output Data Image

Controller Tag

Local:Slot:O:Data

Offset Description

0Protocol Type

1 Node Status

2 Data Block Number

3 Reserved

4

...

In_x

Data

 

79

 

Offset Description

0Protocol Type

1 Node Status

2 Data Block Number

3 Reserved

4

...

Out_x

Data

 

79

 

Input Data

Multiplexer

In_1 In_2 In_3 In_4

..

In_25

Output Data

DeMultiplexer

Out_1 Out_2 Out_3 Out_4

..

Out_25

In [1]

In [24]

Output Data

Out [0]

Out [1]

Out [24]

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Image 24
Contents Applicability & Effectivity Table of Contents Appendix B Troubleshooting Tips Introduction About this product Required configuration for the SlotServer RslogixInstall the SlotServer in a ControlLogix Rack Write the SlotServer configurationInstall the FieldServer Utilities Load the SlotServer Configuration into the SlotServerSlotServer Installation SlotServer Ports and DisplaysLED Technical Specifications Inside Cover Door LabelSlotServer Topology Configuring the SlotServer as a Logix I/O Server Data Arrays/DescriptorsServer Side Connection Descriptors Server Side Node DescriptorsDriver Specific Map Descriptor Parameters Map Descriptors Example Establish an RSLogix project5 Add and configure the SlotServer as an IO Module Write Ladder Program to get Input Data from Data Arrays FS-RA-CLXSlotServerInstructionManualT17011 Very Important Note Set up the third party connection Write Ladder Program to Send Output Data to Data ArraysDownload the RSLogix Program and Run Accessing Multiple Output Data Arrays Multiple Input Data ArraysVery Important Note FS-RA-CLXSlotServerInstructionManualT17011 SlotServer Data Transfer over IO Data Image Appendix A.3. How to obtain Node Status from the SlotServer Appendix A.2. The IO image headerAppendix A.4. Dealing with ControlLogix RPI Settings Appendix A.5.2. Setup Appendix A.5.3. RSLogix configurationAppendix A.5.4. RSNetWorx configuration Appendix A.5.5. Testing FS-RA-CLXSlotServerInstructionManualT17011 Appendix A.6. Rules for Naming Logix driver Data Arrays Wrbc CPU1 INT Rdbc CPU1 INTFS-RA-CLXSlotServerInstructionManualT17011 This page Intentionally Left Blank