FieldServer FS-RA-CLX-BAS instruction manual Wrbc CPU1 INT, Rdbc CPU1 INT

Page 32

 

 

FS-RA-CLX_SlotServer_Instruction_Manual_(T17011)

 

Page 32 of 34

 

 

 

 

 

Example 1: Legal Map Descriptors:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Map_Descriptors

 

 

 

 

 

 

 

 

 

 

 

Map_Descriptor_Name,

Scan_Interval,

Function ,

Node_Name,

IO_Data_Type,

DA_Name_Start,

DA_Count

 

 

 

Input_BP_Image,

0s,

WRBC,

CPU1,

INT,

Test_5,

2

 

 

 

Output_BP_Image,

0s,

RDBC,

CPU1,

INT,

Test_3,

2

 

 

 

Example 2: Illegal Map Descriptors:

 

 

 

 

 

 

 

 

Map_Descriptors

 

 

 

 

 

 

 

 

 

 

 

Map_Descriptor_Name,

Scan_Interval,

Function,

Node_Name,

IO_Data_Type,

DA_Name_Start,

DA_Count

 

 

 

Input_BP_Image,

0s,

WRBC,

CPU1,

INT,

Test_05,

2

 

 

 

Output_BP_Image,

0s,

RDBC,

CPU1,

INT,

Test,

2

 

 

 

Output_BP_Image2,

0s,

RDBC,

CPU1,

INT,

Test_-3,

-5

 

 

 

Output_BP_Image3,

0s,

RDBC,

CPU1,

INT,

Test6,

2

 

 

 

 

 

 

 

 

 

 

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Image 32
Contents Applicability & Effectivity Table of Contents Appendix B Troubleshooting Tips Introduction About this product Required configuration for the SlotServer RslogixInstall the SlotServer in a ControlLogix Rack Write the SlotServer configurationInstall the FieldServer Utilities Load the SlotServer Configuration into the SlotServerSlotServer Installation SlotServer Ports and DisplaysLED Technical Specifications Inside Cover Door LabelSlotServer Topology Configuring the SlotServer as a Logix I/O Server Data Arrays/DescriptorsServer Side Connection Descriptors Server Side Node DescriptorsDriver Specific Map Descriptor Parameters Map Descriptors Example Establish an RSLogix project5 Add and configure the SlotServer as an IO Module Write Ladder Program to get Input Data from Data Arrays FS-RA-CLXSlotServerInstructionManualT17011 Very Important Note Download the RSLogix Program and Run Set up the third party connectionWrite Ladder Program to Send Output Data to Data Arrays Accessing Multiple Output Data Arrays Multiple Input Data ArraysVery Important Note FS-RA-CLXSlotServerInstructionManualT17011 SlotServer Data Transfer over IO Data Image Appendix A.3. How to obtain Node Status from the SlotServer Appendix A.2. The IO image headerAppendix A.4. Dealing with ControlLogix RPI Settings Appendix A.5.2. Setup Appendix A.5.3. RSLogix configurationAppendix A.5.4. RSNetWorx configuration Appendix A.5.5. Testing FS-RA-CLXSlotServerInstructionManualT17011 Appendix A.6. Rules for Naming Logix driver Data Arrays Wrbc CPU1 INT Rdbc CPU1 INTFS-RA-CLXSlotServerInstructionManualT17011 This page Intentionally Left Blank