Hach DR 5000 user manual Advanced Operations Select a user program

Page 79

Advanced Operations

6.1.3 Select a user program

1.Press User Programs in the Main Menu to view an alphabetical list of user programs with program numbers.

The User Programs list will appear.

Note: Use the scroll bar to scroll through the list quickly.

Note: Highlight the selection by pressing it or press Select by Number to search for the program by number.

2.Press Start to run the program.

6.1.4Add, edit and delete user programs from the favorites list

The most frequently used tests/methods in the User Program menu can also be added to the list of favorites to simplify their selection.

1.Press User Programs in the Main Menu. The User Programs list will appear.

2.Highlight the selection by pressing it or press Select by Number to search for the program by number.

Note: Use the scroll bar to scroll through the list quickly. Use the alphanumeric keypad to enter the test number (program number) and press OK to confirm.

3.Press Program Options.

4.Press Add to Favorites, Edit or Delete and press OK to confirm.

Note: If the stored program is deleted in User Programs, it will also be deleted in Favorites Programs.

79

Image 79
Contents January 2008, Edition Page Table of Contents Table of Contents 101 Table of Contents Section Specifications Specifications Use of hazard information Safety informationPrecautionary labels General InformationSource Lamp Safety Chemical and Biological SafetyGeneral Information Class 1 Laser General Information Overview of productGeneral Information Unpack the instrument Section InstallationOperating environment Connection InstallationCell compartment Multi Cell Holder Top and Bottom 1 100 mm adapter optionalInstallation Multi Cell Holder Installation Installation Multi Cell HolderBeam path Beam pathLanguage selection Power the instrument on and offChanging the language setting Start UpStart Up Use of the alphanumeric keypad Standard OperationsOverview Tips for the use of the touch screenMain Menu options Standard Operations Main MenuStandard Operations Instrument Setup modeOperator ID Standard Operations Sample ID Display and sound preferences Date and timeVIS-Lamp and UV-Lamp Lamp ControlEffect caused by the lamp settings on the Measuring Mode Standard Operations Keyboard Printer setupUSB connector Standard Operations PC and printerPrinter Setup Hach Data Trans Print dataPassword Password deactivation Standard Operations Recall stored data from the data log Store, recall, send and delete dataData Log Auto/manual data storageTo send measurement data to a PC Send data from the data logDelete stored data from the data log Recall stored data from wavelength scan or time course Data storage from wavelength scan or time courseSelect Wavelength Scan or Time Course to recall data Send data from wavelength scan or time course Option Press Wavelength Scan or Time Course and then Delete stored data from wavelength scan or time course Stored programs options Stored ProgramsSelect a saved test/method enter user-specific basic data Stored program optionsOptions Description Store Off/On Timer iconReading Mode Standard AdjustSet the reading mode Standard Operations Use of program timersPress OptionsMore…Dilution Factor Set the dilution factorTake single wavelength measurements single reading Take single wavelength measurements continuous readingsRun a standard adjust Press OptionsMoreChemical Form Change of the default setting of the chemical formPress Save as Default Set the chemical formMeasurement/analysis of a reagent blank Standard Operations Run a reagent blankPress OptionsMoreReagent Blank Add stored programs to the favorite programs list Standard Operations Analysis of samplesCell compartment #1 Barcode ProgramsSelect the chemical evaluation form Changing the standard settingStandard Operations Complete a barcode 13 mm test/vial Select the measuring rangeBarcode program options Basic test-specific and sample-specific data settingsOptions Description Send Data icon Sample blankEdit Enter the Name Update/edit barcode testsManual update of a barcode test Program update optionsEnter the Measurement Process Enter the VersionTimer 1, Timer 2, Timer 3 and Timer Press OptionsMoreEdit Update an existing barcode testOption 1 Manual update of test data Option 2 Manual check/revision of test dataProgram a new test Upgrade of the instrument softwarePress OK to return to the System Checks menu Standard Operations User Programs Advanced OperationsProgram a user method Program Type Advanced OperationsProgram Number Program NameWavelength single wavelength program type Single wavelength settingsConcentration resolution number of decimal places UnitsChemical form Multi wavelength settingsAbsorbance formula multi-wavelength program type Wavelength λx List of available absorbance formulasConcentration Factor Kx Calibration settings Calibration settings for single and multi wavelength modeCalibration by entering calibration values Advanced Operations Advanced Operations Advanced Operations Additional user-defined parameters and functions Store a user programUpper and lower limits of the measuring range Chemical form 2 / chemical form 3 / chemical form Timer 1 / Timer 2 / Timer 3 / TimerMeasurement process Advanced Operations Free programming program typeDefinitions of the program points Enter a new element of a measuring sequence Content and definition of the keys Key / ZeroingKey / Reading Process Timer keyEnter calibration formula C1 Enter the calibration formula evaluation formulaDelete an element of a measuring sequence Insert an element of a measuring sequenceScreen Key Description Edit formula key descriptionsNew Number C2 On Enter the next calibration formula C2 or CnSave a free programming user program Enter variablesSelect Conc. key 4 Add, edit and delete user programs from the favorites list Advanced Operations Select a user programEdit Add to FavoritesDelete Recall a favorite program Favorite ProgramsDelete a favorite program Standard Addition monitoring/checking results Measures to identify other interference factors ChecklistMethod Complete a standard addition Peak volume Standard additionSample volume Check the standard solutionPress OptionsMoreStandard Addition Peak volume/sample volume methodsDescription of the table of readings Advanced Operations Single wavelength setup options Set up single wavelength modeProgram Concentration factor Concentration resolutionOptions Description Take single wavelength measurements single reading Reading modeTake single wavelength measurements continuous readings Multi-wavelength setup options Set the reading mode at different wavelengthsAbsorbance formula Press Absorbance Formula Concentration factor For data storage, see .3.1.1 on Wavelength scan setup options Set up the wavelength scanOption Description Setting wavelengthScale & Units Select view displaying table Cursor modeIntegral Scale & units Press Scale & Units Wavelength scan readingNavigating the wavelength scan Highlight Reference Advanced Operations Work with reference scans100 101 Time course setup parametersTime course setup options Time course of absorbance/transmittance102 Time course scan readingTime & interval Scale & units103 Analysis of time course dataNavigating the time scan Navigation of a time scan or a time scan analysis104 Instrument information System checks105 Optical checks Advanced Operations Upgrade of the instrument software106 107 Wavelength check108 Noise check109 110 Stray light check111 Absorbance check112 Drift checkPress Nominal Values 113 Verification kit114 Press VerificationLamp history Output checks115 Service time Advanced Operations Factory service116 117 Instrument Backup118 Restore backup data119 120 Display MaintenanceCleaning requirements Spectrophotometer122 Lamp replacementMaintenance Tungsten lamp replacement123 Deuterium lamp UV replacement124 Fuse replacementFilter pad replacement Filter pad maintenance125 126 Base of DR 5000 with filter grid127 Section Troubleshooting128 Troubleshooting129 Section Replacement PartsDescription Cat.-No 130 Replacement Parts131 Contact Information132 Contact Information133 Limited WarrantyLimitations Limitation of Remedies134 Limited Warranty135 Index136