Dell H810 Multiple Disks Become Inaccessible, Source Disk Fails During Replace Member Operation

Page 7

Firmware Fault State Error Message

75

Foreign Configuration Found Error Message

75

Foreign Configuration Not Found In <Ctrl> <R> Error Message

76

Previous Configuration Cleared Or Missing Error Message

76

Invalid SAS Topology Detected Error Message

76

Multibit ECC Errors Detected Error Messages

76

Configured Disks Removed Or Not Accessible Error Message

77

Battery Discharged Or Disconnected Error Message

77

Degraded State Of Virtual Disks

77

Memory Errors

78

Preserved Cache State

78

General Issues

78

PERC Card Has Yellow Bang In Device Manager

78

PERC Card Not Seen In Device Manager

78

No Hard Drives Found Error Message During Microsoft Windows Server 2003 Installation

78

Physical Disk Issues

79

Physical Disk In Failed State

79

Unable to Rebuild A Fault Tolerant Virtual Disk

79

Fatal Error Or Data Corruption Reported

79

Physical Disk Displayed As Blocked

79

Multiple Disks Become Inaccessible

80

Rebuilding A Failed Physical Disk

80

Virtual Disk Fails During Rebuild Using A Global Hot Spare

80

Virtual Disk Fails During Rebuild Using A Dedicated Hot Spare

80

Physical Disk Fails During Reconstruction On Redundant Virtual Disk

81

Virtual Disk Fails Rebuild Using A Dedicated Hot Spare

81

Physical Disk Takes A Long Time To Rebuild

81

SMART Errors

81

Smart Error Detected On A Physical Disk In A Redundant Virtual Disk

81

Smart Error Detected On A Physical Disk In A Non-Redundant Virtual Disk

82

Replace Member Errors

82

Source Disk Fails During Replace Member Operation

82

Target Disk Fails

82

General Disk Fails

82

Linux Operating System Errors

82

Virtual Disk Policy Is Assumed As Write-Through Error Message

82

Driver Does Not Auto-Build Into New Kernel

83

Unable To Register SCSI Device Error Message

83

Disk Carrier LED Indicators

84

9 Appendix: RAID Description

85

Summary Of RAID Levels

85

Image 7
Contents H710P, and H810 User’s Guide Dell Inc. All Rights Reserved Contents Management Applications For Perc Cards Driver InstallationDeploying The Perc Card Support For Internal Multiple ControllersCacheCade Troubleshooting Security Key Management In The Bios Configuration UtilitySecurity Key And RAID Management Source Disk Fails During Replace Member Operation Multiple Disks Become InaccessibleAppendix RAID Description Disk Mirroring Overview Specification H310 H710 H710PSpans per Disk Group Specification H310 H710 H710P H810Supported Operating Systems Getting HelpRelated Documentation Contacting DellDocumentation Feedback Page There are four power saving modes available FeaturesPhysical Disk Power Management Configured Spin Down DelayFull Initialization Of Virtual Disks Types Of Virtual Disk InitializationConsistency Checks Background Initialization Of Virtual DisksFastPath Using Disk RoamingConfiguring FastPath-Capable Virtual Disks Disk RoamingWrite Virtual Disk MigrationMigrating Virtual Disks ReadWrite-Back And Write-Through Virtual Disk Write Cache PoliciesConditions Under Which Write-Back Is Employed Number Capacity Description Level Reconfiguration Of Virtual DisksVirtual Disk Read Cache Policies Source RAIDOne disk Disk into aMirrored virtual Disk by addingReclaims disk Fault ToleranceSmart Feature Automatic Replace Member With Predicted FailureRedundant Path Support For Perc H810 Only Patrol ReadPhysical Disk Hot Swapping Using Persistent Hot Spare SlotsUsing Replace Member And Revertible Hot Spares Physical Disk Failure DetectionController Cache Preservation Battery Transparent Learn CyclePage Removing The Perc Controller Deploying The Perc CardRemoving and Installing the Perc Adapter PCIe slot SAS cable connectors Perc adapter ScrewRemoving and Installing the Perc Mini Monolithic Controller Installing The Perc ControllerSupport For Internal Multiple Controllers Setting Up Redundant Path Support On The Perc H810 AdapterServer Storage Redundant Path Support Configuration With Two EnclosuresPage Installing a driver Driver InstallationClick Continue Popular support tools section, click Drivers and Downloads Click on the Hardware tab Reboot the system when promptedSelect Install from a list or specific location Updating The Linux DriverUpgrading The Kernel Version installed Page Dell OpenManage Storage Management Bios Configuration UtilityEntering The Bios Configuration Utility Management Applications For Perc CardsNotation Meaning and Use Example Exiting The Configuration UtilityTo exit the Bios Configuration Utility Ctrl R Menu Navigation ControlsMgmt, Ctrl Mgmt, and Foreign View Setting Up Virtual DisksNotation Meaning and Use Ctrl Mgmt, and Foreign ViewSummary Of RAID Levels Parameter DescriptionSelect Create New VD and press Enter Virtual Disk ManagementCreating Virtual Disks ParameterDescriptionConverting Physical Disk To RAID Capable For Perc H310 Selecting Virtual Disk ParametersRunning a Data Consistency Check Converting Physical Disk To Non-RAID For Perc H310Initializing Virtual Disks Checking Data ConsistencyPage Page Managing Preserved Cache Break MirrorChoose Break Mirror and press Enter Select Manage Preserved Cache Managing Dedicated Hot SparesSelect Manage Ded. HS and press Enter Deleting Disk Groups Clearing The ConfigurationSelect Clear Config Deleting Virtual DisksVirtual Disk Management VD Mgmt Bios Configuration Utility Menu OptionsVirtual Disks Physical Disks Security property of the Disk Group Virtual Disks Action Description Virtual Disk ActionsPhysical Disk Actions Physical Disk Management PD MgmtController Management Ctrl Mgmt RebuildController Management Actions Setting LED Blinking Foreign Configuration ViewPhysical Disk Management Removing Global Or Dedicated Hot Spares Creating Global Hot SparesReplacing An Online Physical Disk Stopping Background Initialization Restrictions and LimitationsPerforming a Manual Rebuild Of An Individual Physical Disk Controller Management Enabling Boot SupportEnabling Boot Support For a BIOS-Enabled Controller Enabling Bios Stop On ErrorDisabling Auto Import Uefi RAID Configuration UtilityRestoring Factory Default Settings Entering The Uefi RAID Configuration UtilityController Management Menu Exiting The Uefi RAID Configuration UtilityConfiguration Options Device Settings menuPhysical Disk Management Menu Virtual Disk ManagementEnclosure Management Configuring And Managing CacheCade Virtual Disks CacheCade Virtual Disk CharacteristicsCacheCade Creating CacheCade Virtual Disks CacheCade Virtual Disk ManagementSelect Create CacheCade Virtual Disk and press Enter Manual Resizing Of CacheCade Virtual Disks Reconfiguring CacheCade Virtual DisksAutomatic Reconfiguration Of CacheCade Virtual Disks Deleting CacheCade Virtual DisksPage Local Key Management LKM Security Key Management In The Bios Configuration UtilitySecurity Key And RAID Management Security Key ImplementationChanging The Security Key Creating a Security KeyCreating Secured Virtual Disks Deleting a Security KeySecuring Pre-Existing Virtual Disks Highlight the Secure Disk Group option and press Enter Secured Foreign Import Errors Troubleshooting Security Key ErrorsInstant Secure Erase Failure To Instant Secure Erase Task On Physical Disks Failure To Delete Security KeyExtra Enclosure Error Message TroubleshootingBios Error Messages Discovery Error MessagePrevious Configuration Of Disks Removed Error Message Missing Disks In Virtual Disk Error MessageMissing Virtual Disks Error Message Bios Disabled Error Message Dirty Cache Data Error MessageDrive Configuration Changes Error Message Action Cable problems, press any key or Y to continue Adapter At Baseport Not Responding Error MessageVirtual Disks Offline Error Message Virtual Disks Degraded Error MessageForeign Configuration Found Error Message Virtual Disks Partially Degraded Error MessageMemory Or Battery Problem Error Message Firmware Fault State Error MessageMultibit ECC Errors Detected Error Messages Foreign Configuration Not Found In Ctrl R Error MessagePrevious Configuration Cleared Or Missing Error Message Invalid SAS Topology Detected Error MessageBattery Discharged Or Disconnected Error Message Configured Disks Removed Or Not Accessible Error MessageDegraded State Of Virtual Disks Perc Card Has Yellow Bang In Device Manager Memory ErrorsGeneral Issues Preserved Cache StatePhysical Disk In Failed State Physical Disk IssuesUnable to Rebuild a Fault Tolerant Virtual Disk Fatal Error Or Data Corruption ReportedVirtual disk Multiple Disks Become InaccessibleVirtual Disk Fails During Rebuild Using a Global Hot Spare Rebuilding a Failed Physical DiskVirtual Disk Fails Rebuild Using a Dedicated Hot Spare Smart ErrorsPhysical Disk Takes a Long Time To Rebuild Error Replace Member ErrorsLinux Operating System Errors Issue General disk fails CorrectiveDriver Does Not Auto-Build Into New Kernel Unable To Register Scsi Device Error MessageInstall a DKMS-enabled driver package Reboot to the new kernelActivity LED Status LED Disk Carrier LED IndicatorsDisk Striping Appendix RAID DescriptionSummary Of RAID Levels RAID TerminologySpanned RAID Levels Disk MirroringParity Data Example of Distributed Parity RAID
Related manuals
Manual 136 pages 19.9 Kb

H310, H710, H710P, H810 specifications

Dell offers a range of storage controller technologies, notably the H810, H710, H710P, and H310, which cater to different enterprise needs. These controllers are designed to support various storage configurations, enhancing overall system performance and reliability.

The Dell H810 is a high-performance PCIe 3.0 RAID controller that supports up to eight internal drives and is particularly suited for demanding workloads. It features advanced RAID levels including RAID 0, 1, 5, 6, 10, 50, and 60, providing flexibility for various data protection strategies. The H810 also supports up to 32TB of storage capacity, making it suitable for environments that require substantial data management capabilities.

The H710 is another powerful RAID controller, widely recognized for its balance of performance and cost-efficiency. It features 1GB of cache memory, which aids in accelerating read and write operations. The H710 supports the same RAID levels as the H810 and allows for up to 512MB of non-volatile memory. This ensures data integrity even in the event of a power failure, making it reliable for critical applications.

The H710P is an enhanced version of the H710, with a significant upgrade in its cache capabilities. It offers 2GB of battery-backed cache memory, further enhancing data processing speeds and improving responsiveness. The H710P is ideal for intensive workloads and virtualization, where rapid access to data is essential. This controller also includes features such as RAID storage pooling, intelligent data tiering, and support for multiple virtual disks.

Finally, the H310 is a cost-effective option for small to medium-sized businesses or those with less demanding storage requirements. It offers similar RAID support as the higher-end controllers but operates with a simpler architecture. The H310 features 512MB of cache, providing sufficient performance for regular workloads without the additional complexities of more advanced controllers.

In summary, Dell's H810, H710, H710P, and H310 storage controllers each serve distinct purposes, providing various features, technologies, and performance characteristics tailored to different business needs. From high-capacity storage solutions to user-friendly setups, Dell’s offerings ensure that organizations can efficiently manage their data storage requirements.