Dell M1000E Downloading The CMC Firmware, Updating The CMC Firmware Using The Web-Based Interface

Page 30

NOTE: In a redundant CMC configuration, care must be taken to update CMC firmware on both modules. Failure to do so may cause unexpected behavior during a CMC failover or failback. Use the following procedure for redundant CMC deployments.

1.Locate the secondary or standby CMC by using the RACADM getsysinfo command, or by using the Chassis Summary page in the web-based interface. Visually, the status indicator is solid blue on the primary or active CMC module and off on the standby or secondary CMC.

2.Update the firmware on the standby CMC first, using the web-based interface or RACADM.

3.Verify that the secondary or standby CMC’s firmware is at the requested level with the getsysinfo command or using the web-based interface.

4.After the standby CMC has rebooted, update the firmware on the active or primary CMC. Allow 10 minutes for the standby CMC to boot.

5.Verify that the active or primary CMC firmware is at the requested level using the getsysinfo command or using the web-based interface.

6.Once both CMCs are updated to the same firmware revision, use the cmcchangeover command to reset the CMC in the left slot as primary.

Downloading The CMC Firmware

Before beginning the firmware update, download the latest firmware version from support.dell.com, and save it to your local system. The following software components are included with your CMC firmware package:

Compiled CMC firmware code and data

Web-based interface, JPEG, and other user interface data files

Default configuration files

Use the Firmware Update page to update the CMC firmware to the latest revision. When you run the firmware update, the update retains the current CMC settings.

NOTE: The firmware update, by default, retains the current CMC settings. During the update process, you have the option to reset the CMC configuration settings back to the factory default settings.

Updating The CMC Firmware Using The Web-Based Interface

1.Log in to the web-based interface.

2.Click Chassis in the system tree.

3.Click the Update tab. The Updatable Components page is displayed.

4.On the Updatable Components page, click the CMC name. The Firmware Update page is displayed.

5.In the Value field, type the path on your management station or shared network where the firmware image file resides, or click Browse to navigate to the file location.

NOTE: The default CMC firmware image name is firmimg.cmc and this filename must not be changed. Ensure that you keep different firmware revisions separated as the file name always remains the same.

6.Click Update. A dialog box prompts to confirm the action.

7.Click Yes to continue. The firmware transfer process begins and the status displays the message Firmware Update in Progress. After the CMC update is complete, the CMC is reset and you must refresh the User Interface page to log in again.

30

Image 30
Contents Regulatory Model BMX01 Dell Inc. All Rights Reserved Contents Configuring The I/O Modules General I/O Module Configuration GuidelinesInstalling Enclosure Components Modules-Pass-ThroughTroubleshooting The Enclosure Technical SpecificationsGetting Help About Your System System OverviewBlade Numbering Full Height Blades System Control-Panel Features Control-Panel FeaturesLCD Module LCD Module Features LCD DisplayKeyAction Left and right arrows Move between screens Configuration WizardUsing The LCD Module Menus Center buttonBack-Panel Features Back-Panel FeaturesPower Supply Indicators Back-Panel Module Bay NumberingAC power source Icon Present indicator Description DC power to the systemPower supply fault indicator Icon Description SupplyFan Module Indicators Indicator Description Fan power indicator Solid GreenAvocent iKVM Analog Switch Module Optional Avocent Analog iKVM Switch Module IndicatorsAvocent Analog iKVM Switch Module Features Link indicator OffGreen CMC Module Features CMC ModuleCMC Fail-Safe Mode Condition Description CMC removalCMC network cable Daisy-Chain CMC Network Connection ConditionDescriptionSystem Messages Other Information You May NeedPage Page Initial Setup Sequence Initial CMC Network ConfigurationBefore You Begin Configuring The CMC Using The LCD Configuration Wizard Configuring The CMC Using a Management Station And CLILogging In To The CMC Using The Web-Based Interface Https//CMC IP addressHttps//CMC IP addressport number Configuring iDRAC Networking Using The Web-Based Interface Adding And Managing CMC UsersInstalling Or Updating The CMC Firmware Setting The First Boot Device For ServersConfiguring And Managing Power Click Setup → DeployUpdating The CMC Firmware Using The Web-Based Interface Downloading The CMC FirmwareTiering The Avocent iKVM Switch From a Digital KVM Switch Configuring The Optional iKVM Switch ModuleUpdating The CMC Firmware Using Racadm Updating The iKVM FirmwareTiering The Avocent iKVM Switch From An Analog KVM Switch Configuring The Analog SwitchClick Setup → Devices → Device Modify Viewing And Selecting Servers FlexAddress FlexAddress PlusConnectivity General I/O Module Configuration GuidelinesNetwork Information Fabric aFabric B Fabric CFull-Height Blades PowerEdge M610x OnlyMezzanine Cards Half-Height BladesEthernet switch Module Port Mapping-Full-Height Blades Standard LOM Dual-Port MappingDual-Port Mezzanine Cards Example of PowerEdge M610x Port Mapping Blade Blade Module Mezzanine Card C Port Mezzanine Card BBlade Module Blade Module Quad-Port Mezzanine Cards Portn+16 Module Port MappingHalf-Height Blades Example of Half-Height Blade Port Mapping Modules-Switches Blade n ModuleBrocade M6505 16 Gbps FC SAN I/O Module Brocade M6505 16 Gbps FC SAN I/O ModuleDell PowerEdge M I/O Aggregator Switch Cisco Nexus B22 Fabric Extender ModuleDell Force10 MXL 10/40 GbE Switch Dell PowerEdge M I/O Aggregator SwitchMellanox M4001F/M4001Q/M4001T Infiniband Switch I/O Module Dell Force10 MXL 10/40 GbE Switch I/O ModuleDell PowerConnect KR 8024-k Switch Mellanox M4001F/M4001Q/M4001T Infiniband Switch ModuleDell PowerConnect M8428-k 10 Gb Converged Network Switch Dell PowerConnect KR 8024-k SwitchMellanox M2401G DDR Infiniband Switch I/O Module Dell PowerConnect M8428-k 10 Gb Converged Network SwitchMellanox M3601Q QDR Infiniband Switch I/O Module Mellanox M2401G DDR Infiniband Switch ModuleCisco Catalyst Ethernet Switch I/O Modules Mellanox M3601Q QDR Infiniband Switch I/O ModuleDell PowerConnect M6348 1 Gb Ethernet Switch I/O Module Cisco Catalyst Ethernet Switch Module FeaturesDell PowerConnect M6220 Ethernet Switch I/O Module PowerConnect M6348 1 Gb Ethernet Switch I/O Module FeaturesDell PowerConnect M8024 10 Gb Ethernet Switch I/O Module PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M8024 10 Gb Ethernet Switch I/O Module Dell 8/4 Gbps FC SAN ModuleBrocade M5424 FC8 I/O Module Dell 8/4 Gbps FC SAN ModuleIndicator Status Off No signal carrier Amber on Brocade M5424 FC8 I/O ModuleModules-Pass-Through Dell 4 Gbps Fibre Channel Pass-Through ModuleGreen on, two fast amber blinks 2 Gb link established With EmulexGreen on, one fast amber blink 1 Gb link established Green on, three fast amber blinks 4 Gb link establishedDell 10 GbE KR Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module 10/100/1000 Mb Ethernet Pass-Through I/O ModuleActivity indicators Power indicator Link indicators Page Removing And Installing a Blade Recommended ToolsRemoving a Blade Blade handle Guide rail on enclosure Release button Power Supply Blanks Power Supply ModulesInstalling a Blade AC Power Supply ModulesRemoving An AC Power Supply Installing An AC Power Supply DC Power Supply Modules Wiring Instructions For a DC Power SupplyInput Requirements Assembling The DC Input Power Wires And DC Power Connector DC power socket Removing a DC Power Supply Installing a DC Power Supply Fan Modules Removing a Fan ModuleInstalling a Fan Module Removing a CMC ModuleInstalling a CMC Module CMC Module SD CardIKVM Module Click the Power Management tabSelect the Reset CMC warm boot button Removing An iKVM ModuleInstalling An iKVM Module ModulesInstalling An I/O Module Removing An I/O ModuleEnclosure Bezel Removing The Enclosure BezelInstalling The Enclosure Bezel Removing The Front Module Cage Assembly And MidplaneEnclosure Midplane Front module cage assembly Installing The Midplane And Front Module Cage Assembly Removing and Installing the MidplaneEnclosure Control Panel Assembly Removing The Control PanelInstalling The Control Panel Removing The LCD ModuleInstalling The LCD Module Removing and Installing the LCD ModuleTroubleshooting The Enclosure Troubleshooting Enclosure ComponentsTroubleshooting a Wet Enclosure Troubleshooting Power Supply ModulesTroubleshooting Fan Modules Troubleshooting The iKVM ModuleTroubleshooting I/O Modules Page Enclosure Specifications Power Supply ModuleChassis Management Controller Module Module SpecificationsOptional Avocent iKVM Module Enclosure Control PanelPowerConnect M6220 Ethernet Switch Module Dell PowerEdge M I/O Aggregator Switch ModuleDell Force10 MXL 10/40 GbE Switch Module Brocade M6505 16 Gbps FC SAN I/O ModuleMellanox Infiniband Switch Module Brocade FC8 Fibre Channel Switch ModuleBrocade FC4 Fibre Channel Switch Module Gb Ethernet Pass-Through ModuleEnvironmental Ethernet switch I/O module Getting Help Contacting Dell
Related manuals
Manual 2 pages 36.05 Kb Manual 108 pages 15.26 Kb Manual 86 pages 34.71 Kb Manual 86 pages 40.45 Kb Manual 12 pages 5.14 Kb

M1000E specifications

The Dell M1000E blade enclosure is a robust and versatile platform designed to optimize data center efficiency and streamline server management. A fundamental component of Dell's PowerEdge series, the M1000E is engineered to house multiple server blades in a compact, modular chassis, enabling organizations to conserve space and reduce power consumption while enhancing performance.

One of the main features of the Dell M1000E is its ability to accommodate up to 16 half-height server blades or 8 full-height server blades. This flexibility allows for a diverse range of configurations tailored to specific workloads, whether for virtualization, database management, or application hosting. The chassis provides shared power supplies and cooling, further contributing to the enclosure's efficient operation.

In terms of connectivity, the M1000E includes integrated high-speed networking capabilities. It can support multiple generations of networking technologies, ranging from Gigabit Ethernet to 10 Gigabit Ethernet, and offers options for Fibre Channel and InfiniBand connections. This extensive range of networking options ensures that organizations can integrate the M1000E into existing infrastructures seamlessly.

The Dell M1000E also utilizes advanced management tools to simplify administration and monitoring. One of the standout features is the Dell OpenManage suite, which provides a comprehensive set of tools for hardware management and system updates. Users gain insights into system health, performance, and power usage, enabling proactive maintenance and optimization of resources.

The enclosure is designed with scalability in mind. As businesses grow, the M1000E can be expanded easily by adding more blades without the need for significant reconfiguration. This scalability ensures that IT departments can respond rapidly to changing demands, ensuring that resources align with organizational requirements.

From a security standpoint, the M1000E provides multiple layers of protection, including secure access controls and configurable management interfaces. This helps safeguard sensitive information and ensures compliance with stringent data protection regulations.

Overall, the Dell M1000E blade enclosure represents a compelling solution for modern data centers, merging performance, efficiency, and scalability into a single chassis designed to meet the demands of today’s enterprise environments. Its advanced technologies and features make it a valuable asset for organizations looking to enhance their IT infrastructure.