Dell M1000E owner manual FlexAddress Plus

Page 34

FlexAddress

The FlexAddress feature allows server modules to replace the factory assigned World Wide Name and Media Access Control (WWN/MAC) network IDs with WWN/MAC IDs provided by the chassis. FlexAddress is delivered on a Secure Digital (SD) card that must be inserted into the CMC to provide the chassis-assigned WWN/MAC IDs.

Every server module is assigned unique WWN and MAC IDs as part of the manufacturing process. Before the FlexAddress feature was introduced, if you had to replace one server module with another, the WWN/MAC IDs would change and Ethernet network management tools and SAN resources would need to be reconfigured to be aware of the new server module.

FlexAddress allows the CMC to assign WWN/MAC IDs to a particular slot and override the factory IDs. If the server module is replaced, the slot-based WWN/MAC ID remains the same. This feature eliminates the need to reconfigure Ethernet network management tools and SAN resources for a new server module.

Additionally, the override action only occurs when a server module is inserted in a FlexAddress enabled chassis; no permanent changes are made to the server module. If a server module is moved to a chassis that does not support FlexAddress, the factory assigned WWN/MAC IDs are used.

Prior to installing FlexAddress, you can determine the range of MAC addresses contained on a FlexAddress feature card by inserting the SD card into an USB Memory Card Reader and viewing the file pwwn_mac.xml. This clear text XML file on the SD card contains an XML tag mac_start, which is the first starting hex MAC address that will be used for this unique MAC address range. The mac_count tag is the total number of MAC addresses that the SD card allocates. The total MAC range allocated can be determined by:

<mac_start> + 0xCF (208 - 1) = mac_end

For example:

(starting_mac)00188BFFDCFA + 0xCF = (ending_mac)00188BFFDDC9

NOTE: To prevent modifying any of the contents accidentally, you must lock the SD card prior to inserting in the USB "Memory Card Reader". You must then unlock the SD card before inserting it into the CMC.

For more information on the FlexAddress feature, see the following resources:

The CMC Secure Digital (SD) Card Technical Specification document at support.dell.com/manuals

The Help link in the CMC web interface

The FlexAddress information in the CMC User’s Guide at support.dell.com/manuals

FlexAddress Plus

FlexAddress Plus expands the number of MAC addresses to 3136 from the original FlexAddress pool of 208. FlexAddress Plus is provided on the FlexAddress Plus Secure Digital (SD) card along with the FlexAddress feature.

NOTE: The SD card labeled FlexAddress only contains FlexAddress and the card labeled FlexAddress Plus contains FlexAddress and FlexAddress Plus. The card must be inserted into the CMC to activate the feature.

34

Image 34
Contents Regulatory Model BMX01 Dell Inc. All Rights Reserved Contents Configuring The I/O Modules General I/O Module Configuration GuidelinesInstalling Enclosure Components Modules-Pass-ThroughTechnical Specifications Troubleshooting The EnclosureGetting Help About Your System System OverviewBlade Numbering Full Height Blades System Control-Panel Features Control-Panel FeaturesLCD Module LCD Module Features LCD DisplayKeyAction Left and right arrows Move between screens Configuration WizardUsing The LCD Module Menus Center buttonBack-Panel Features Back-Panel FeaturesPower Supply Indicators Back-Panel Module Bay NumberingAC power source Icon Present indicator Description DC power to the systemPower supply fault indicator Icon Description SupplyFan Module Indicators Indicator Description Fan power indicator Solid GreenAvocent iKVM Analog Switch Module Optional Avocent Analog iKVM Switch Module IndicatorsLink indicator Off Avocent Analog iKVM Switch Module FeaturesGreen CMC Module Features CMC ModuleCondition Description CMC removal CMC Fail-Safe ModeCMC network cable Daisy-Chain CMC Network Connection ConditionDescriptionSystem Messages Other Information You May NeedPage Page Initial CMC Network Configuration Initial Setup SequenceBefore You Begin Configuring The CMC Using The LCD Configuration Wizard Configuring The CMC Using a Management Station And CLIHttps//CMC IP address Logging In To The CMC Using The Web-Based InterfaceHttps//CMC IP addressport number Configuring iDRAC Networking Using The Web-Based Interface Adding And Managing CMC UsersInstalling Or Updating The CMC Firmware Setting The First Boot Device For ServersConfiguring And Managing Power Click Setup → DeployUpdating The CMC Firmware Using The Web-Based Interface Downloading The CMC FirmwareTiering The Avocent iKVM Switch From a Digital KVM Switch Configuring The Optional iKVM Switch ModuleUpdating The CMC Firmware Using Racadm Updating The iKVM FirmwareConfiguring The Analog Switch Tiering The Avocent iKVM Switch From An Analog KVM SwitchClick Setup → Devices → Device Modify Viewing And Selecting Servers FlexAddress FlexAddress PlusConnectivity General I/O Module Configuration GuidelinesNetwork Information Fabric aFabric B Fabric CFull-Height Blades PowerEdge M610x OnlyMezzanine Cards Half-Height BladesEthernet switch Standard LOM Dual-Port Mapping Module Port Mapping-Full-Height BladesDual-Port Mezzanine Cards Example of PowerEdge M610x Port Mapping Blade Blade Module Mezzanine Card C Port Mezzanine Card BBlade Module Blade Module Quad-Port Mezzanine Cards Portn+16 Module Port MappingHalf-Height Blades Example of Half-Height Blade Port Mapping Modules-Switches Blade n ModuleBrocade M6505 16 Gbps FC SAN I/O Module Brocade M6505 16 Gbps FC SAN I/O ModuleDell PowerEdge M I/O Aggregator Switch Cisco Nexus B22 Fabric Extender ModuleDell Force10 MXL 10/40 GbE Switch Dell PowerEdge M I/O Aggregator SwitchMellanox M4001F/M4001Q/M4001T Infiniband Switch I/O Module Dell Force10 MXL 10/40 GbE Switch I/O ModuleDell PowerConnect KR 8024-k Switch Mellanox M4001F/M4001Q/M4001T Infiniband Switch ModuleDell PowerConnect M8428-k 10 Gb Converged Network Switch Dell PowerConnect KR 8024-k SwitchMellanox M2401G DDR Infiniband Switch I/O Module Dell PowerConnect M8428-k 10 Gb Converged Network SwitchMellanox M3601Q QDR Infiniband Switch I/O Module Mellanox M2401G DDR Infiniband Switch ModuleCisco Catalyst Ethernet Switch I/O Modules Mellanox M3601Q QDR Infiniband Switch I/O ModuleDell PowerConnect M6348 1 Gb Ethernet Switch I/O Module Cisco Catalyst Ethernet Switch Module FeaturesDell PowerConnect M6220 Ethernet Switch I/O Module PowerConnect M6348 1 Gb Ethernet Switch I/O Module FeaturesDell PowerConnect M8024 10 Gb Ethernet Switch I/O Module PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M8024 10 Gb Ethernet Switch I/O Module Dell 8/4 Gbps FC SAN ModuleBrocade M5424 FC8 I/O Module Dell 8/4 Gbps FC SAN ModuleIndicator Status Off No signal carrier Amber on Brocade M5424 FC8 I/O ModuleModules-Pass-Through Dell 4 Gbps Fibre Channel Pass-Through ModuleGreen on, two fast amber blinks 2 Gb link established With EmulexGreen on, one fast amber blink 1 Gb link established Green on, three fast amber blinks 4 Gb link establishedDell 10 GbE KR Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through Module 10/100/1000 Mb Ethernet Pass-Through I/O ModuleActivity indicators Power indicator Link indicators Page Recommended Tools Removing And Installing a BladeRemoving a Blade Blade handle Guide rail on enclosure Release button Power Supply Blanks Power Supply ModulesInstalling a Blade AC Power Supply ModulesRemoving An AC Power Supply Installing An AC Power Supply DC Power Supply Modules Wiring Instructions For a DC Power SupplyInput Requirements Assembling The DC Input Power Wires And DC Power Connector DC power socket Removing a DC Power Supply Installing a DC Power Supply Fan Modules Removing a Fan ModuleInstalling a Fan Module Removing a CMC ModuleInstalling a CMC Module CMC Module SD CardIKVM Module Click the Power Management tabSelect the Reset CMC warm boot button Removing An iKVM ModuleInstalling An iKVM Module ModulesInstalling An I/O Module Removing An I/O ModuleEnclosure Bezel Removing The Enclosure BezelRemoving The Front Module Cage Assembly And Midplane Installing The Enclosure BezelEnclosure Midplane Front module cage assembly Installing The Midplane And Front Module Cage Assembly Removing and Installing the MidplaneEnclosure Control Panel Assembly Removing The Control PanelInstalling The Control Panel Removing The LCD ModuleInstalling The LCD Module Removing and Installing the LCD ModuleTroubleshooting The Enclosure Troubleshooting Enclosure ComponentsTroubleshooting a Wet Enclosure Troubleshooting Power Supply ModulesTroubleshooting The iKVM Module Troubleshooting Fan ModulesTroubleshooting I/O Modules Page Enclosure Specifications Power Supply ModuleChassis Management Controller Module Module SpecificationsOptional Avocent iKVM Module Enclosure Control PanelPowerConnect M6220 Ethernet Switch Module Dell PowerEdge M I/O Aggregator Switch ModuleDell Force10 MXL 10/40 GbE Switch Module Brocade M6505 16 Gbps FC SAN I/O ModuleMellanox Infiniband Switch Module Brocade FC8 Fibre Channel Switch ModuleBrocade FC4 Fibre Channel Switch Module Gb Ethernet Pass-Through ModuleEnvironmental Ethernet switch I/O module Getting Help Contacting Dell
Related manuals
Manual 2 pages 36.05 Kb Manual 108 pages 15.26 Kb Manual 86 pages 34.71 Kb Manual 86 pages 40.45 Kb Manual 12 pages 5.14 Kb

M1000E specifications

The Dell M1000E blade enclosure is a robust and versatile platform designed to optimize data center efficiency and streamline server management. A fundamental component of Dell's PowerEdge series, the M1000E is engineered to house multiple server blades in a compact, modular chassis, enabling organizations to conserve space and reduce power consumption while enhancing performance.

One of the main features of the Dell M1000E is its ability to accommodate up to 16 half-height server blades or 8 full-height server blades. This flexibility allows for a diverse range of configurations tailored to specific workloads, whether for virtualization, database management, or application hosting. The chassis provides shared power supplies and cooling, further contributing to the enclosure's efficient operation.

In terms of connectivity, the M1000E includes integrated high-speed networking capabilities. It can support multiple generations of networking technologies, ranging from Gigabit Ethernet to 10 Gigabit Ethernet, and offers options for Fibre Channel and InfiniBand connections. This extensive range of networking options ensures that organizations can integrate the M1000E into existing infrastructures seamlessly.

The Dell M1000E also utilizes advanced management tools to simplify administration and monitoring. One of the standout features is the Dell OpenManage suite, which provides a comprehensive set of tools for hardware management and system updates. Users gain insights into system health, performance, and power usage, enabling proactive maintenance and optimization of resources.

The enclosure is designed with scalability in mind. As businesses grow, the M1000E can be expanded easily by adding more blades without the need for significant reconfiguration. This scalability ensures that IT departments can respond rapidly to changing demands, ensuring that resources align with organizational requirements.

From a security standpoint, the M1000E provides multiple layers of protection, including secure access controls and configurable management interfaces. This helps safeguard sensitive information and ensures compliance with stringent data protection regulations.

Overall, the Dell M1000E blade enclosure represents a compelling solution for modern data centers, merging performance, efficiency, and scalability into a single chassis designed to meet the demands of today’s enterprise environments. Its advanced technologies and features make it a valuable asset for organizations looking to enhance their IT infrastructure.