Dell M1000E owner manual Viewing And Selecting Servers

Page 33

NOTE: In addition to the steps outlined above, some external analog switches may require you to perform additional steps to ensure that the iKVM switch blades are displayed in the external analog switch OSCAR. For more information, see the external analog switch documentation.

Resynchronizing The Server List At The Remote Client Workstation

Once the iKVM module is connected, the blades are displayed in OSCAR. You must re-synchronize the servers on any remote workstation to ensure that the blades are available to any remote users connected to the console switch through the Remote Console Switch software.

NOTE: This procedure only re-synchronizes one remote client workstation. With multiple client workstations, save the re-synchronized local database and load it into the other client workstations to ensure consistency.

To re-synchronize the server listing:

1.Click Resync in the Server category of the Management panel. The resync wizard launches.

2.Click Next. A warning message is displayed indicating that the database will be updated to match the current configuration of the console switch. Your current local database names will be overwritten with the switch names. To include unpowered SIPs in the re-synchronization, select the Include Offline SIPs check box.

3.Click Next. A Polling Remote Console Switch message box is displayed with a progress bar indicating that the switch information is being retrieved.

4.If no changes were detected in the appliance, a completion dialog box is displayed with this information. If server changes were detected, then the Detected Changes dialog box is displayed.

5.Click Next to update the database.

If a cascade switch was detected, the Enter Cascade Switch Information dialog box is displayed.

6.Select the type of switch connected to the appliance from the drop-down list. If the type you are looking for is not available, you can add it by clicking Add.

7.Click Next. The completion dialog box is displayed.

8.Click Finish to exit.

9.Start up the analog switch and the system.

Viewing And Selecting Servers

Use the OSCAR Main dialog box to view, configure, and manage servers in the M1000e enclosure through the iKVM. You can view the servers by name or by slot. The slot number is the chassis slot number the server occupies. The Slot column indicates the slot number in which a server is installed.

NOTE: Server names and slot numbers are assigned by the CMC.

NOTE: If you have enabled access to the CMC though the iKVM, an additional option, Dell CMC Console, is displayed.

To access the Main dialog box, press <PrintScreen> to launch the OSCAR interface. The Main dialog box is displayed.

or

If a password has been assigned, the Password dialog box is displayed. Type your password and click OK. The Main dialog box is displayed.

33

Image 33
Contents Regulatory Model BMX01 Dell Inc. All Rights Reserved Contents General I/O Module Configuration Guidelines Configuring The I/O ModulesModules-Pass-Through Installing Enclosure ComponentsTroubleshooting The Enclosure Technical SpecificationsGetting Help System Overview About Your SystemBlade Numbering Full Height Blades Control-Panel Features System Control-Panel FeaturesLCD Module LCD Display LCD Module FeaturesUsing The LCD Module Menus Configuration WizardKeyAction Left and right arrows Move between screens Center buttonBack-Panel Features Back-Panel FeaturesBack-Panel Module Bay Numbering Power Supply IndicatorsPower supply fault indicator Icon Description DC power to the systemAC power source Icon Present indicator Description SupplyIndicator Description Fan power indicator Solid Green Fan Module IndicatorsAvocent Analog iKVM Switch Module Indicators Avocent iKVM Analog Switch Module OptionalAvocent Analog iKVM Switch Module Features Link indicator OffGreen CMC Module CMC Module FeaturesCMC Fail-Safe Mode Condition Description CMC removalCMC network cable ConditionDescription Daisy-Chain CMC Network ConnectionOther Information You May Need System MessagesPage Page Initial Setup Sequence Initial CMC Network ConfigurationBefore You Begin Configuring The CMC Using a Management Station And CLI Configuring The CMC Using The LCD Configuration WizardLogging In To The CMC Using The Web-Based Interface Https//CMC IP addressHttps//CMC IP addressport number Adding And Managing CMC Users Configuring iDRAC Networking Using The Web-Based InterfaceConfiguring And Managing Power Setting The First Boot Device For ServersInstalling Or Updating The CMC Firmware Click Setup → DeployDownloading The CMC Firmware Updating The CMC Firmware Using The Web-Based InterfaceUpdating The CMC Firmware Using Racadm Configuring The Optional iKVM Switch ModuleTiering The Avocent iKVM Switch From a Digital KVM Switch Updating The iKVM FirmwareTiering The Avocent iKVM Switch From An Analog KVM Switch Configuring The Analog SwitchClick Setup → Devices → Device Modify Viewing And Selecting Servers FlexAddress Plus FlexAddressNetwork Information General I/O Module Configuration GuidelinesConnectivity Fabric aFabric C Fabric BMezzanine Cards PowerEdge M610x OnlyFull-Height Blades Half-Height BladesEthernet switch Module Port Mapping-Full-Height Blades Standard LOM Dual-Port MappingDual-Port Mezzanine Cards Blade Module Mezzanine Card C Port Mezzanine Card B Example of PowerEdge M610x Port Mapping BladeBlade Module Blade Module Quad-Port Mezzanine Cards Portn+16 Module Port MappingHalf-Height Blades Example of Half-Height Blade Port Mapping Blade n Module Modules-SwitchesBrocade M6505 16 Gbps FC SAN I/O Module Brocade M6505 16 Gbps FC SAN I/O ModuleCisco Nexus B22 Fabric Extender Module Dell PowerEdge M I/O Aggregator SwitchDell PowerEdge M I/O Aggregator Switch Dell Force10 MXL 10/40 GbE SwitchDell Force10 MXL 10/40 GbE Switch I/O Module Mellanox M4001F/M4001Q/M4001T Infiniband Switch I/O ModuleMellanox M4001F/M4001Q/M4001T Infiniband Switch Module Dell PowerConnect KR 8024-k SwitchDell PowerConnect KR 8024-k Switch Dell PowerConnect M8428-k 10 Gb Converged Network SwitchDell PowerConnect M8428-k 10 Gb Converged Network Switch Mellanox M2401G DDR Infiniband Switch I/O ModuleMellanox M2401G DDR Infiniband Switch Module Mellanox M3601Q QDR Infiniband Switch I/O ModuleMellanox M3601Q QDR Infiniband Switch I/O Module Cisco Catalyst Ethernet Switch I/O ModulesCisco Catalyst Ethernet Switch Module Features Dell PowerConnect M6348 1 Gb Ethernet Switch I/O ModulePowerConnect M6348 1 Gb Ethernet Switch I/O Module Features Dell PowerConnect M6220 Ethernet Switch I/O ModulePowerConnect M6220 Ethernet Switch I/O Module Dell PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module PowerConnect M8024 10 Gb Ethernet Switch I/O ModuleDell 8/4 Gbps FC SAN Module Brocade M5424 FC8 I/O ModuleBrocade M5424 FC8 I/O Module Indicator Status Off No signal carrier Amber onDell 4 Gbps Fibre Channel Pass-Through Module Modules-Pass-ThroughGreen on, one fast amber blink 1 Gb link established With EmulexGreen on, two fast amber blinks 2 Gb link established Green on, three fast amber blinks 4 Gb link establishedDell 10 GbE KR Pass-Through I/O Module 10/100/1000 Mb Ethernet Pass-Through I/O Module Dell 10 Gb Ethernet Pass-Through ModuleActivity indicators Power indicator Link indicators Page Removing And Installing a Blade Recommended ToolsRemoving a Blade Blade handle Guide rail on enclosure Release button Installing a Blade Power Supply ModulesPower Supply Blanks AC Power Supply ModulesRemoving An AC Power Supply Installing An AC Power Supply Wiring Instructions For a DC Power Supply DC Power Supply ModulesInput Requirements Assembling The DC Input Power Wires And DC Power Connector DC power socket Removing a DC Power Supply Installing a DC Power Supply Removing a Fan Module Fan ModulesRemoving a CMC Module Installing a Fan ModuleCMC Module SD Card Installing a CMC ModuleSelect the Reset CMC warm boot button Click the Power Management tabIKVM Module Removing An iKVM ModuleModules Installing An iKVM ModuleRemoving An I/O Module Installing An I/O ModuleRemoving The Enclosure Bezel Enclosure BezelInstalling The Enclosure Bezel Removing The Front Module Cage Assembly And MidplaneEnclosure Midplane Front module cage assembly Removing and Installing the Midplane Installing The Midplane And Front Module Cage AssemblyRemoving The Control Panel Enclosure Control Panel AssemblyRemoving The LCD Module Installing The Control PanelRemoving and Installing the LCD Module Installing The LCD ModuleTroubleshooting Enclosure Components Troubleshooting The EnclosureTroubleshooting Power Supply Modules Troubleshooting a Wet EnclosureTroubleshooting Fan Modules Troubleshooting The iKVM ModuleTroubleshooting I/O Modules Page Power Supply Module Enclosure SpecificationsOptional Avocent iKVM Module Module SpecificationsChassis Management Controller Module Enclosure Control PanelDell Force10 MXL 10/40 GbE Switch Module Dell PowerEdge M I/O Aggregator Switch ModulePowerConnect M6220 Ethernet Switch Module Brocade M6505 16 Gbps FC SAN I/O ModuleBrocade FC4 Fibre Channel Switch Module Brocade FC8 Fibre Channel Switch ModuleMellanox Infiniband Switch Module Gb Ethernet Pass-Through ModuleEnvironmental Ethernet switch I/O module Contacting Dell Getting Help
Related manuals
Manual 2 pages 36.05 Kb Manual 108 pages 15.26 Kb Manual 86 pages 34.71 Kb Manual 86 pages 40.45 Kb Manual 12 pages 5.14 Kb

M1000E specifications

The Dell M1000E blade enclosure is a robust and versatile platform designed to optimize data center efficiency and streamline server management. A fundamental component of Dell's PowerEdge series, the M1000E is engineered to house multiple server blades in a compact, modular chassis, enabling organizations to conserve space and reduce power consumption while enhancing performance.

One of the main features of the Dell M1000E is its ability to accommodate up to 16 half-height server blades or 8 full-height server blades. This flexibility allows for a diverse range of configurations tailored to specific workloads, whether for virtualization, database management, or application hosting. The chassis provides shared power supplies and cooling, further contributing to the enclosure's efficient operation.

In terms of connectivity, the M1000E includes integrated high-speed networking capabilities. It can support multiple generations of networking technologies, ranging from Gigabit Ethernet to 10 Gigabit Ethernet, and offers options for Fibre Channel and InfiniBand connections. This extensive range of networking options ensures that organizations can integrate the M1000E into existing infrastructures seamlessly.

The Dell M1000E also utilizes advanced management tools to simplify administration and monitoring. One of the standout features is the Dell OpenManage suite, which provides a comprehensive set of tools for hardware management and system updates. Users gain insights into system health, performance, and power usage, enabling proactive maintenance and optimization of resources.

The enclosure is designed with scalability in mind. As businesses grow, the M1000E can be expanded easily by adding more blades without the need for significant reconfiguration. This scalability ensures that IT departments can respond rapidly to changing demands, ensuring that resources align with organizational requirements.

From a security standpoint, the M1000E provides multiple layers of protection, including secure access controls and configurable management interfaces. This helps safeguard sensitive information and ensures compliance with stringent data protection regulations.

Overall, the Dell M1000E blade enclosure represents a compelling solution for modern data centers, merging performance, efficiency, and scalability into a single chassis designed to meet the demands of today’s enterprise environments. Its advanced technologies and features make it a valuable asset for organizations looking to enhance their IT infrastructure.