Important Safety Instructions

Warning

Warning

Warning

Warning

Caution

Caution

Warning

Read these instructions.

Keep these instructions.

Heed all warnings.

Follow all instructions.

The safe operation of this product requires that a protective earth connection be provided. A grounding conductor in the equipment's supply cord provides this protective earth. To reduce the risk of electrical shock to the operator and service personnel, this ground conductor must be connected to an earthed ground.

Use only power cords specified for this product and certified for the country of use. Refer to the Product Power Cord Requirement Section that follows.

Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit in to your outlet, consult an electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinching particularly at plugs, convenience receptacles, and point where they exit from the apparatus.

Indoor Use: “WARNING – TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPERATUS TO RAIN OR MOISTURE”

Do not use this apparatus near water.

Do not block any ventilation openings. Install in accordance with manufacturer’s instructions.

Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

Only use attachments/accessories specified by the manufacturer.

Unplug this apparatus during lightning storms or when unused for long periods of time.

Clean only with a dry cloth.

Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug damage, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Certain parts of this equipment still present a safety hazard, with the power switch in the OFF position. To avoid electrical shock, disconnect all A/C power cords from the chassis' rear appliance connectors before servicing.

To reduce the risk of fire, replacement fuses must be the same type and rating.

Service barriers within this product are intended to protect the operator and service personnel from hazardous voltages. For continued safety, replace all barriers after servicing.

This product contains safety critical parts, which if incorrectly replaced may present a risk of fire or electrical shock. Components contained within the product’s power supplies and power supply area, are not intended to be customer serviced and should be returned to the factory for repair.

Page 4

8310/8321 User Manual (V 1.0)

Image 4
Contents OpenGearTM 2RU Frame Power Supply PS-8300 Cobalt Digital IncCopyright TrademarksImportant Regulatory and Safety Notices Symbol MeaningsImportant Safety Instructions EMC Notices Product Power Cord RequirementsUS FCC Part Maintenance/User Serviceable Parts Environmental InformationContents Ordering Information Service InformationContact Us Introduction This ChapterWord of Thanks OverviewFeatures Robust Power SuppliesDocumentation Terms Installation and Setup Static DischargeUnpacking Installing the Frame Power Supply PS-8300 and Power CableInstalling the Frame Power Supply Hazardous VoltagesFault Reporting Improving PerformanceVentilation and Cooling Color Display and DescriptionFan Kit Installed Power Cable ConnectionCable Connections Without Fan KitRear I/O Modules BNC Rear I/O ModuleRear I/O Module Installation Smpte Alarm ConnectorEthernet Connector OpenBUS ConnectorDual Reference Connectors Smpte 269M Fault Reporting Option Frame Connections DetailsSpecifications Technical SpecificationsReporting Smpte FaultEnvironmental Important Notes Frame Features Installing the Cooling Fan Module Cooling FeaturesFan Board Installation Instructions Frame Door Features Cooling Fan Functions and User ControlsInstalling the Controller Card Functions of the Controller CardMFC-8310 Alarm Configuration Jumper Alarm Mute ButtonControls and LEDs for the Controller Card MFC-8310 LEDsMFC-8310 Controller Card LED Descriptions Installing the Network Controller Card Remote Control Networking FeaturesEthernet Setup Functions of the Network Controller Card Controls and LEDs for the Network Controller CardDIP Switches on the MFC-8310-N Buttons on the MFC-8310-NReset Button MFC-8310-N LEDsSnmp Monitoring and Control DashBoard and DashBoard Lite Control System SoftwareColor Location Display and Description Enabling Snmp Configuring SnmpOperating Tip Installing the Rear Support Bars and Brackets Rear Support Bars and Brackets8321 20-Slot Frame Setup Rear Modules for the 8321 Series Frames Split Rear Module Cooling Features Specifications for the 8321 Series Frames Troubleshooting Checklist Service InformationFrame Controller Alarm Mute/Bootload Button Page Warranty and Repair Policy Cobalt Digital Inc. Limited WarrantyStandard Equipment Ordering InformationOptional Equipment Page Contact Cobalt Digital Inc Contact UsVisit us at the Cobalt Digital Inc. website

8321(-C), 8310(-C) specifications

Cobalt Networks was known for its pioneering role in the development of high-performance server appliances, particularly with its 8300 series, which includes the 8310(-C) and 8321(-C) models. These devices are recognized for their reliability, scalability, and efficiency, making them ideal solutions for web hosting, content delivery, and database management.

The Cobalt 8310(-C) model primarily targets small to medium-sized businesses looking for a cost-effective yet powerful server solution. It features a robust hardware design, powered by a dedicated processor that ensures speedy performance and low latency for applications. With its capacity to handle multiple simultaneous connections, the 8310(-C) is well-suited for web applications and e-commerce platforms. Its compact form factor allows for easy installation in server racks, contributing to efficient space utilization in data centers.

On the other hand, the Cobalt 8321(-C) is designed for larger enterprises requiring enhanced performance and greater scalability. This model includes a multicore processor and offers higher RAM and storage options, allowing businesses to support more demanding applications and larger databases. The 8321(-C) is particularly beneficial for organizations that anticipate growth, as it can be easily scaled up with additional resources, ensuring that service quality remains consistent even during peak loads.

Both models share several key features that underscore Cobalt Networks' commitment to performance and reliability. They incorporate advanced cooling technologies to maintain optimal operating temperatures, prolonging hardware lifespan and enhancing reliability. Additionally, both models support a variety of operating systems and virtualization technologies, providing the flexibility needed to run diverse applications.

Security is another critical characteristic of the 8310(-C) and 8321(-C). They come equipped with robust security protocols, including firewall and intrusion detection systems, ensuring that sensitive data is protected from unauthorized access and cyber threats.

In summary, the Cobalt Networks 8310(-C) and 8321(-C) models stand out due to their performance, scalability, and security features. These servers are suited for businesses of varying sizes, supporting a range of applications while ensuring reliability and efficiency in demanding environments. As organizations continue to embrace digital transformation, these models remain relevant due to their robust technologies and capabilities.