7.DIP SWITCH SETTING
7.1Serial Interface Type
Switch No. | Function | OFF | ON | Factory Setting | |
| 1 | Character direction | Normal | Inverted | OFF |
*1 | 2 (3110) | CR | — | — | OFF |
*1 | 2 (910) | CR | Ignore CR | CR + LF | OFF |
| 3 | Reset in | Disable | Enable | ON |
| *2 4 | Bit length | 8 bits | *3 7 bits | OFF |
*1: A difference is developed by the emulation set by the memory switch.
*2: After setting DIP switch No. 4 to ON, turning the printer power on with the SEL switch pressed and held causes the printer to enter the Manual memory switch setting mode. With normal power on operation, bit length setting is active.
*3: This setting may cause some restrictions such as limiting the argument of control code or incomplete format of data in bit image printing.
Baud rate and parity selection
| Switch No. |
| Parity | Baud Rate | Factory Setting | ||
8 | 7 | 6 | 5 | ||||
|
|
| |||||
OFF | OFF | OFF | OFF | None | 4800 | O | |
OFF | OFF | OFF | ON | None | 1200 | — | |
OFF | OFF | ON | OFF | None | 2400 | — | |
OFF | OFF | ON | ON | None | 4800 | — | |
OFF | ON | OFF | OFF | None | 9600 | — | |
OFF | ON | OFF | ON | None | 19200 | — | |
OFF | ON | ON | OFF | Odd | 1200 | — | |
OFF | ON | ON | ON | Odd | 2400 | — | |
ON | OFF | OFF | OFF | Odd | 4800 | — | |
ON | OFF | OFF | ON | Odd | 9600 | — | |
ON | OFF | ON | OFF | Odd | 19200 | — | |
ON | OFF | ON | ON | Even | 1200 | — | |
ON | ON | OFF | OFF | Even | 2400 | — | |
ON | ON | OFF | ON | Even | 4800 | — | |
ON | ON | ON | OFF | Even | 9600 | — | |
ON | ON | ON | ON | Even | 19200 | — |
— 31 —