Onboard FDC Controller
Select “Enabled” if your system has a floppy disk controller (FDC) installed on the system board and you wish to use it. If you install an
Onboard Serial Port 1
Select an address and corresponding interrupt for the first serial port. Options: Disabled, 3F8/IRQ4 (default), 2F8/IRQ3, 3E8/IRQ4, 2E8/IRQ3, Auto.
Onboard Serial Port 2
Select an address and corresponding interrupt for the second serial port. Options: Disabled, 2F8/IRQ3 (default), 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3, Auto.
UART Mode Select
This item allows you to select the Infra Red (IR) standard to be used. Options: Normal (default), AS KIR, IrDA.
RxD, TxD Active
This item determines the RxD and TxD frequencies. Options: Hi / Lo (default), Hi / Hi, Lo / Hi, Lo / Lo.
IR Transmission Delay
This item allows you to enable/disable IR transmission delay. Options: Enabled (default), Disabled.
UR2 Duplex Mode
Select the transmission mode used by the IR interface.
Use IR Pins
Consult your IR peripheral documentation to select the correct setting of the TxD and RxD signals. Options: Full, Half (default).
Onboard Parallel Port
Select an address and corresponding interrupt for the onboard parallel port. Options: 378/IRQ7 (default), 278/IRQ5, 3BC/IRQ7, Disabled.
Parallel Port Mode
This option allows you to select an parallel port mode for the on board parallel port.
ECP (default) | Extended Capabilities Port. |
EPP | Enhanced Parallel Port. |
SPP | Standard Printer Port. |
ECP+EPP | ECP & EPP mode. |
Normal |
|
EPP Mode Select
Select EPP port type 1.7 or 1.9. Options: EPP 1.9(default), EPP 1.7.
ECP Mode Use DMA
Select a DMA Channel for the parallel port during ECP mode. Options: 3 (default), 1.
33