Graco 309504E instruction manual Tank Setup

Page 24

System Administrator Screens

Changing User Information.

1.Select the user information to change and click Modify.

2.Select and change the information.

3.Click Apply to update the record.

Removing a User

In the Action Column of the user record, click remove to remove the user record from the System Users Setup screen.

Modifying User Information

1.In the Action Column of the user record, click mod- ify. The Select settings below dialogue box appears. See FIG. 41.

2.Change the data as needed.

If the Security Status is changed from Basic to either Administrator or Work Orders, new pass- words, allowing access, must be entered.

3.Click Apply. The changes are made. If the security level previously selected is for Administrator or Work Orders, either existing passwords or new passwords must be entered to apply the changes.

Tank Setup _______________________________________________

Click Tank Setup to go to the Tank Setup screen (FIG. 43). Tanks must be configured before meters can be config- ured.

FIG. 43 Tank Setup Screen

Customized Fluid Setup

To add, edit, or remove a fluid from the Tank setup, click the Customized Fluid List button located in the upper left corner of the Tank Setup screen. See FIG. 43. The Fluid Setup dialogue box appears. See FIG. 44.

To Add a new fluid to the entry list

Click Add. Type in the new fluid name and a description, and select the type of fluid from the drop down box. Click Add to add a fluid to the list. You will need to provide a fluid name, description, and select if it’s Oil/ATF, Gear Lube, or Anti-Freeze 50/50. For ease of reading else-

where in the program and in the reports, a short name is FIG. 44 Select a fluid entry to add or remove recommended. Click Apply to update the record.

To Remove a fluid

Select the fluid to remove, and click Remove. The record is deleted from the list and you return to the Tank Setup screen.

Adding a New Tank using a TLM

1.Click Add Tank. A new blank record is added. Tanks must be setup and programmed prior to meters being setup. See FIG. 45.

2.Select modify for the newly added tank

24

309504E

Image 24
Contents Tank Level Monitor TLM Software Contents General Matrix System Specifications System RequirementsPC Hardware Requirements Pop-Up Blocker PC Software RequirementsMail Special Considerations for pop-up blockersGeneral guidelines to find and configure pop-up blockers Software Firewalls Windows XP SecuritySpecial Considerations for Firewalls Installation Instructions Stand Alone ConfigurationNetworked Configurations Browser Configuration Setup Path 1- Typical Matrix Server and ClientSetup Path 1 InstallShield Wizard Setup Path 1 Firewall Question Setup Path 2 Matrix Client Only Start / All Programs / StartupOn the Windows Desktop Setup Path 2 Choose Setup Type Setup Path 2 Install Complete Clock and Time Zone Settings Sun Java RuntimeMatrixLogs Folder Software Installation Troubleshooting Uninstalling Matrix on Windows XP Operator Screens Tank Level InformationBattery Level Information System Administrator Screens Matrix System SetupSystem Configuration Unit of Measure English or MetricEdit Contact Information Transceiver Setup Transceiver Power-upConfirm PC/Transceiver Communication ExampleSystem Administrator Screens System User Setup Adding a System Administrator UserTank Setup Edit Tank Setup Tank Shape Screen Vertical Tank GeometryVerifying Capacity for Obround and Cylindrical Tanks Manual Tank Adjustment Removing a TankProgramming the Tank Level Monitor RecommendationsMail Setup Mail ConfigurationSystem Status Adding an E-Mail EventRemoving an E-Mail Event Modifying E-mail EventsSystem Administrator Screens 309504E Matrix Reporter Production DataStarting Matrix Reporter Creating a ReportSaving Report Data to File Exporting the Matrix DatabasePrinting Report Data Filtering Report DataImporting a Matrix Database File Database file import instructionsTroubleshooting Graco Standard Warranty Graco Phone Numbers