Graco 309504E Transceiver Setup, Transceiver Power-up, Confirm PC/Transceiver Communication

Page 21

Transceiver Setup

Click the Add Transceiver button, then click Modify.

1.Enter the area of the shop where the transceiver is located (i.e., Main Shop, Fast Lube Shop, Engine Department) in the Transceiver Name field.

2.The Network ID is a letter designation for the Trans- ceiver network identification. The default is (A). There are eight network ID’s available designated with the letters A through H. Type in the selected Network ID.

The Network ID letter for a given Transceiver must match that Transceiver’s dipswitch set- tings.

3.Transceiver ID is a letter designation for the Trans- ceiver Identification. The default is (A). There are eight Transceiver ID’s available designated with the letters A through H.

The Transceiver ID letter for a given Transceiver must match that Transceivers equivalent dip- switch settings.

4.Serial Port is a pull down menu of all available com- munication ports on the Matrix PC. COM 1 is the default setting. If COM 1 is not available, select an open port from the pull down list.

Some computers may not have any serial ports. In this case a USB converter will be required to obtain serial ports. Graco recommends Edge- port models from B & B Electronics.

If you attempt to add a Transceiver and the PC has no COM ports available, an error message appears. Contact your IT professional or add serial ports using the USB convertors recom- mended by Graco. See page 3 for additional information.

Firmware Revision is the Transceiver firmware revision level.

Transceiver Power-up

Graco recommends that when you plug in the power cord to the transceiver, do it with the PC serial cable already plugged in.

System Administrator Screens

Confirm PC/Transceiver Communication

Each time a transceiver is powered up, it reads its dip switch settings for Network ID and Transceiver ID and sends this information to the PC. It also sends the trans- ceiver’s firmware revision level. These settings are dis- played as “Last Power-up Settings” and “Firmware Revision” on this screen. If these fields are “N/A”, it means that the transceiver has never (successfully) communicated with the PC.

One way to confirm that the serial connection between PC and transceiver is functioning properly is to change the transceiver dip switch settings and verify that the PC software reflects the new settings. Refer to the trans- ceiver manual on how to set transceiver dip switches.

Example:

A Matrix system has a single transceiver, the desired settings on the transceiver setup screen (Fig. 18) are Network ID = A, Transceiver ID = A, and Serial Port = COM1 (factory defaults).

FIG. 39

1.If it’s open, close the transceiver setup screen (Fig. 18).

2.Power off the transceiver.

3.Set the transceiver dipswitch settings to: Network ID = H

Transceiver ID = H

Refer to transceiver manual 309498 for instructions.

4.With one end of the serial cable already plugged into the PC and the other end in the transceiver, power up the transceiver.

309504E

21

Image 21
Contents Tank Level Monitor TLM Software Contents General Matrix System Specifications System RequirementsPC Hardware Requirements PC Software Requirements Pop-Up BlockerMail Special Considerations for pop-up blockersGeneral guidelines to find and configure pop-up blockers Software Firewalls Windows XP SecuritySpecial Considerations for Firewalls Installation Instructions Stand Alone ConfigurationNetworked Configurations Setup Path 1- Typical Matrix Server and Client Browser ConfigurationSetup Path 1 InstallShield Wizard Setup Path 1 Firewall Question Setup Path 2 Matrix Client Only Start / All Programs / StartupOn the Windows Desktop Setup Path 2 Choose Setup Type Setup Path 2 Install Complete Clock and Time Zone Settings Sun Java RuntimeMatrixLogs Folder Software Installation Troubleshooting Uninstalling Matrix on Windows XP Tank Level Information Operator ScreensBattery Level Information Matrix System Setup System Administrator ScreensSystem Configuration Unit of Measure English or MetricEdit Contact Information Transceiver Power-up Transceiver SetupConfirm PC/Transceiver Communication ExampleSystem Administrator Screens Adding a System Administrator User System User SetupTank Setup Edit Tank Setup Tank Shape Screen Vertical Tank GeometryVerifying Capacity for Obround and Cylindrical Tanks Removing a Tank Manual Tank AdjustmentRecommendations Programming the Tank Level MonitorMail Configuration Mail SetupAdding an E-Mail Event System StatusRemoving an E-Mail Event Modifying E-mail EventsSystem Administrator Screens 309504E Production Data Matrix ReporterStarting Matrix Reporter Creating a ReportExporting the Matrix Database Saving Report Data to FilePrinting Report Data Filtering Report DataDatabase file import instructions Importing a Matrix Database FileTroubleshooting Graco Phone Numbers Graco Standard Warranty