IP POWER 9212 USER MANUAL
Source mode ( Voltage input) :
NOTE:
1. The data in this figure is the average measure value. To ensure the correct detection, we suggest user set the voltage lower than 3V when it shows OFF and higher than 4V when it shows ON
2. The maximum measure voltage is 24V.
.
Slink mode (Resistance Input ) :
0Ω~200Ω, 9212 shows ON. If the resistance within 500Ω~∞, 9212 shows OFF. So user can detect the movement of equipment through the magnetic reed switch or other kind of reactive sensors.
NOTE:
1. The data in this figure is the average measure value. To ensure the correct detection, we suggest user set the voltage lower than 200Ω when it shows ON and higher than 500Ω when it shows OFF.
2. When measure the resistance of web contacts, the maximum voltage is 5V and the maximum currency is no more than 10mA。
PS: magnetic reed switch: using the magnetic field of the magnet to produce a signal when there is a movement happened in switch. Low cost and easy to use is the chief characteristic of magnetic reed switch. Most of them are used in security equipment, living product and automatic mechanism.
9202 Pro Hardware connection (recommend)
IP Power 9202 Pro offers 4 sets of NC(Normal Close ) – Out 1- Out 4 4 sets of NO (Normal Open )
Maximum Rated Voltage: 240V/AC, 60V/DC
Maximum Rated Currency: 12A AC/DC
Maximum Switch time: Max 10ms
Environment Temperature:
NOTICE: Only the professionals should operate the following operations in this section and the common user DO NOT try it!
For
1 Use the electrical wire of the equipment:
- 9 - | VER. X.X, |