MegaVision Network Management System manual Bar Graphs, Graph Options Dialog

Page 22

Figure 12. Graph Options Dialog.

1.Polling Interval Changes the value for the Lines graph main window and its parent (see figure 8.)

2.Min Y, Max Y, Min t, Max t Changes the scaling ranges for the Y-axis and X (t) axis. If you check Automatic Change of Ranges, changes are made automatically. NOTE: For graphs, where the X-axis indicates time, the X check box should be always checked. Sometimes it is better to turn off the Y check box, especially when graphs have peaks.

3.Show in the graph Change these values to correspond to the type of statistic a graph contains. For example, Absolute Value (number of packets), Relative to X (packets/second), Value in percents (same function as Absolute Value, but data ranges from 0 to 100%)

Legend - Opens a sub-window that displays the current statistics: category, time elapsed, and value. Category names and port numbers are color-coded corresponding to lines on the graph.

Figure 13. Legend Dialog.

Grid - Adds a grid to the graph. To delete the grid, click on the button again.

Bar Graphs

Image 22
Contents MegaVision Network Management System Contact Information Contents MegaVision-WEB OverviewMegaVision Classic MegaVision Features Quick Start Page Page MegaVision-WEB platform requirements To Login as a Supervisor LoggingTo Login as a User Using Passwords To Change Password Settings As a User Or SupervisorMain Window Main Window Shortcut IconsMain Window Notes Adding Background Images Set Background ImageDevice Main Window Device Main WindowControl Windows Graphics Support Graphics ImageSpeedometers SpeedometerLine Graphs Line GraphMultiple Line Graphs Bar Graphs Graph Options DialogBar Graph Alarms Alarm NotificationsAlarms Configuration Window Alarms Configuration WindowMail Configuration window Remote MegaVision-WEB GUI interface Snmp Management Information Base MIB Browser MIBView WindowPage Interfaces Monitoring Interfaces Table WindowInterfaces Statistics per Interface Window Page Page Interfaces Utilization window Rmon Support Rmon Group 1 Statistics WindowGroup 1 is not fully supported for this device Rmon Group 2 History Window Rmon Group 2 WindowDesired Interface Number Rmon Groups 3 & 9 Alarms and Events Alarms control TableAdd Rmon Group 3 Window Events Table Add Event Rmon Group 9 WindowEvent Description Adding and Deleting Devices. Describe Window Describe Window Modifying Device Settings SubmapsMap with a submap Cutting, Pasting, Dragging, and Dropping Open Map WindowAutodiscovery Autodiscovery WindowLinks General Device Information Snmp Device Identify Window Snmp Device Identify WindowGeneric Snmp and TCP/IP Devices, Monitoring services Generic Snmp DeviceMonitoring Services Services Configuration Window Alias Manager Page TereScope Management On/Off Status MegaVision-WEB under HP OV NNM Unix MegaVision Classic under HP OpenView Windows MegaVision Classic under Castle Rock SNMPc Network Manager MegaVision Classic under Spectrum 4.0 for Windows NT