Minuteman UPS MCP 2000i, MCP 3000 Receiving Inspection, Please Save the Packing Materials

Page 6

Receiving Inspection

After removing your Minuteman UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored.

The packing materials that your UPS were shipped in are carefully designed to minimize any shipping damage. In the unlikely case that the UPS needs to be returned to Minuteman, please use the original packing material. Since Minuteman is not responsible for shipping damage incurred when the system is returned, the original packing material is inexpensive insurance.

PLEASE SAVE THE PACKING MATERIALS!

WARNING! RISK OF ELECTRICAL SHOCK. HAZARDOUS LIVE PARTS IN- SIDE THIS POWER SUPPLY ARE ENERGIZED FROM THE BATTERY EVEN WHEN THE AC INPUT POWER IS DISCONNECTED.

TO DE-ENERGIZE THE OUTPUTS OF THE UPS:

1.IF THE UPS IS ON, PRESS THE ON/OFF BUTTON.

2.DISCONNECT THE UPS FROM THE AC POWER OUTLET.

3.TO DE-ENERGIZE THE UPS COMPLETELY, DISCONNECT THE BATTERY.

CAUTION! TO REDUCE THE RISK OF ELECTRICAL SHOCK IN CONDITIONS WHERE LOAD EQUIPMENT GROUNDING CANNOT BE VERIFIED, DISCONNECT THE UPS FROM THE AC POWER OUTLET BEFORE INSTALLING A COMPUTER INTERFACE CABLE. RECONNECT THE POWER CORD ONLY AFTER ALL SIGNALING CONNECTIONS ARE MADE.

CAUTION! CONNECT THE UPS TO A TWO POLE, THREE WIRE GROUNDING AC POWER OUTLET. THE RECEPTACLE MUST BE CONNECTED TO APPROPRI- ATE BRANCH PROTECTION (CIRCUIT BREAKER OR FUSE). CONNECTION TO ANY OTHER TYPE OF RECEPTACLE MAY RESULT IN A SHOCK HAZARD AND VIOLATE LOCAL ELECTRICAL CODES.

NOTE: FOR HARDWIRE I/O CONFIGURATIONS FOR THE MCP 2000(i) AND THE MCP 3000(i),

UNITS ARE CONSIDERED FIXED. AN INSULATED GROUNDING CONDUCTOR SHOULD BE IDENTICAL IN SIZE, THICKNESS, AND INSULATION MATERIAL TO THE GROUNDED AND UNGROUNDED BRANCH-CIRCUIT SUPPLY CONDUCTORS. THE WIRE, WHICH SHOULD BE GREEN OR GREEN WITH ONE OR MORE YELLOW STRIPES, IS TO BE INSTALLED AS PART OF THE BRANCH CIRCUIT THAT SUPPLIES THE UNIT. THE GROUNDING CONDUCTOR DE- SCRIBED IN THE ABOVE ITEM SHALL BE GROUNDED TO THE EARTH END OF THE PRO- TECTEDEQUIPMENT.

NOTE: OVERCURRENT PROTECTION IS TO BE PROVIDED BY OTHERS.

NOTE: THE SOUND PRESSURE LEVEL AT THE OPERATORS POSITION ACCORDING TO IEC 704-1:1982 IS EQUAL TO OR LESS THAN 70dB(A).

4

Image 6
Contents MCP Series Page MCP Series User’s Manual Explanation of Symbols Important Safety Instructions Receiving Inspection Please Save the Packing MaterialsPara Systems Life Support Policy Power Switch LED IndicatorsFront Panel Rear Panel MCP 1000i Rear Panel MCP 2000 Rear Panel MCP 2000i Rear Panel MCP 3000 Rear Panel Installation Placement Computer Interface Connections OUT a ConnectionTurning the Unit ON/OFF Communication Interface HardwareTroubleshooting Chart Symtom Possible Cause What To DoReplacing the Batteries Battery pack connection UPSIf the UPS Requires Service MCP Acceptable Input Voltage Limited Product Warranty Except AS Provided HEREIN, Para Systems Makes no WarrantiesPage Page 34000130 REV

MCP 1000, MCP 3000i, MCP 2000i, MCP 2000, MCP 3000 specifications

The Minuteman UPS product line offers a range of uninterruptible power supplies designed to protect critical equipment from power disturbances. The models MCP 1000i, MCP 2000, MCP 2000i, MCP 3000, and MCP 3000i provide reliable backup power and advanced features that ensure continuous operation for sensitive electronics used in both home and business environments.

Starting with the MCP 1000i, this model features a capacity of 1000 VA and is equipped with line-interactive technology. This ensures that it can automatically adjust to power fluctuations without switching to battery mode, which prolongs battery life. With a user-friendly LCD interface, users can easily monitor voltage levels and battery status, ensuring peace of mind in critical situations.

The MCP 2000 and MCP 2000i models increase power capacity to 2000 VA. Both variants offer similar functionalities, but the ā€œiā€ version integrates an advanced LCD display for enhanced monitoring capabilities. They come equipped with multiple outlets, allowing users to connect various devices while maintaining protection against surges and outages. Both versions boast high-efficiency operation, which minimizes energy waste and reduces operating costs.

Moving to the MCP 3000 and MCP 3000i models, these UPS units are designed for larger power demands, offering 3000 VA capacity. The MCP 3000 maintains a line-interactive topology, providing continuous protection against brownouts and voltage spikes. The augmented MCP 3000i boasts an advanced LCD interface, providing real-time information and alerts, allowing users to diagnose issues quickly and effortlessly. This series is suitable for powering critical servers, networking equipment, and high-performance workstations.

Key features across all models include an energy-saving Green Mode, which maximizes efficiency by reducing energy consumption. They also incorporate Smart Battery Management, which enhances battery performance and longevity through intelligent charging and discharging cycles. Robust surge protection helps safeguard devices against transient voltage spikes.

These Minuteman UPS systems are designed with user convenience in mind, featuring hot-swappable batteries for effortless maintenance without shutting down connected devices. Overall, the MCP series provides reliable power protection, advanced technology, and user-friendly features, making them suitable solutions for both home and professional environments in need of uninterrupted power.