Verifying IntelliChlor power
If you have installed the IntelliChlor option, after the IntelliChlor has been connected to the EasyTouch Load center, check the following IntelliChlor LEDs to verify that the IntelliChlor is powered up (see page 7).
•Verify that the green IntelliChlor status LED is lit on the EasyTouch load center control panel.
•Verify that the green IntelliChlor power LED is lit on the IntelliChlor cell. See the IntelliChlor User’s Guide (P/N 520589) for more troubleshooting information.
•Use the following troubleshooting table if the IntelliChlor green status LED in not on.
Troubleshooting IntelliChlor
Problem | Possible Cause | Corrective Action | |
|
|
| |
The IntelliChlor power LED is | Fuse in EasyTouch Load Center is open. | Reset the AC fuse, located in the | |
not on. The power LED is |
| EasyTouch control panel. | |
located on the EasyTouch |
|
| |
No AC power to EasyTouch Load Center. | Verify 110 VAC or 220 VAC to EasyTouch | ||
Load Center control panel. | |||
|
| Load Center when active. | |
|
|
| |
| Transformer leads not wired correctly in | Verify transformer leads wired to AC | |
| EasyTouch Load Center. | source by referring to wiring diagram on | |
|
| page 23. | |
|
|
|
EasyTouch Load Center Installation Guide