Powercom 1500A, 800A, 2000AL, ls600A Troubleshooting, Storage conditions, Extended storage

Page 14

8)Place your new battery in the same position/direction and reconnect the wires red wire-position(+) and black wire negative(-)

9)Please follow steps 5,4 and 3 (in that order) to reconnect the entire unit.

10)Please follow manual instructions in order to properly reconnect your equipment.

11. Storage

10.1 Storage conditions

Store the UPS covered and upright in a cool , dry location, with its battery fully charged. Before storing, charger the UPS for at least 4 hours. Remove any accessories in the accessory slot and disconnect any cables connected to the computer interface port to avoid unnecessary draining the battery.

10.2 Extended storage

During extended storage in environments where the ambient temperature is -15 to +30 (+5 to +86 ), charge the UPS‘ s battery every 6 months.

During extended storage in environments where the ambient temperature is +30

to +45

(+86 to +113 ), charge the UPS‘ s battery every 3 months.

12. Troubleshooting

PROBLEM

POSSIBLE

ACTION TO TAKE

 

On/test button not

Press the on/test button to power the UPS

 

pushed or push too

and the load

 

short

 

 

UPS input circuit

Reduce the load on the UPS by unplugging

UPS will not turn on

break tripped

equipment and reset the circuit breaker by

 

 

pressing the plunger back in

 

 

 

 

Very low or no utility

Check the AC power supply to the UPS with

 

voltage

multimeter

 

Computer interface

Disconnect the computer interface or

UPS will not turn on or

of accessory

accessory. If the UPS now works normally,

off

problem

check the interface cable, the attached

Push on/test or off

computer and the accessory

 

 

button too short

 

UPS operates on-

UPS’ s input circuit

Reduce the load on the UPS by unplugging

battery even though

breaker tripped

equipment and reset the circuit breaker

normal line voltage is

 

 

UPS beeps occasionally

Normal UPS operation

Normal condition

UPS does not provide

The UPS’ s battery is

Charge the battery

 

 

 

Image 14
Contents USER’S Manual Important safety instructions Please read this manualTable of contents Safety IntroductionON/TEST button PresentationFront Panel Yellow LED 11 TEL./MODEM Surge ProtectionComputer Interface InstallationSite Wiring Fault Indicators RED LED Connect the telephone/modem lines Connect external battery pack optionalCharge the battery Connect to UtilitySwitch off Check the Site Wiring Fault IndicatorSwitch on OperationSilence Shutdown modeSelf-test Bttery charge bar graphAlarm Software optionsComputer Interface Port MaintenanceComputer interface port has the following characteristics Battery Replacement Storage conditions TroubleshootingStorage Extended storageBattery Pack Installation BlackSpecifications REDInterface Net Weight 18.0 23.5 26.1 28.4 Nominal Battery 48V 24V Voltage Built-in Charge Current

ls600A, 2000AL, 2500A, 3000A &1000AL, 1000A specifications

The Powercom 3000AL is a high-performance power distribution unit designed to support various electrical applications with exceptional efficiency and reliability. This model is particularly notable for its current capacities of 800A, 1250A, 1500A, and 2000A, offering significant versatility for different operational requirements.

One of the standout features of the Powercom 3000AL is its robust design, which ensures durability and longevity even in challenging environments. Built with high-quality materials, this power distribution unit can withstand extreme temperatures and potential mechanical stress, making it suitable for industrial, commercial, and institutional applications.

In terms of technology, the Powercom 3000AL employs advanced power management capabilities. It includes smart monitoring systems that enable real-time tracking of power consumption and performance. This functionality is invaluable for identifying inefficiencies or potential faults in the power distribution system, allowing for proactive maintenance and minimizing downtime.

Additionally, the unit is equipped with multiple protection features, including overload protection and short circuit protection. These safety measures ensure that the system remains operational under various load conditions while safeguarding connected equipment from damage.

The Powercom 3000AL also features modularity in its design, which allows users to customize and expand their power distribution setup based on evolving needs. This flexibility is essential for businesses that anticipate growth or fluctuations in their power requirements.

Furthermore, the unit incorporates energy-efficient technologies that reduce power loss, contributing to lower operational costs. It is compliant with international energy standards, emphasizing its commitment to sustainability and environmental responsibility.

Overall, the Powercom 3000AL with its capacities of 800A, 1250A, 1500A, and 2000A represents a reliable solution for high-capacity power distribution. Its combination of durable construction, advanced monitoring technology, safety features, and energy efficiency make it a valuable asset in any power management strategy. As industries continue to evolve, the versatility and dependability of the Powercom 3000AL ensure it meets the demands of modern energy usage effectively.