Powercom 2500A, 800A, 2000AL, 3000A &1000AL, 1500A, ls600A Yellow LED, 11 TEL./MODEM Surge Protection

Page 6

power the loads. ON/TEST also activates the UPS's self-test and utility line voltage displays.

3.2 " OVERLOAD" indicator (RED LED)

The LED lights when the loads connected to the UPS exceed the UPS's capacity. See Section 6.3.

3.3 "BACK UP" indicator (GREEN LED)

The LED illuminates when the UPS is supplying battery power to the loads.

3.4 "REPLACE BATTERY" indicator (RED LED)

The LED illuminates when the UPS's battery is no longer useful and must be replaced. See section 9.

Note: When replace battery, disconnect the utility power then open the case and take notice of the battery's polarity while install the new battery to avoid short. See section 9.

3.5"BUCK AVR (VOLTAGE REDUCTION)" indicator

(YELLOW LED)

The LED illuminates when the UPS is correcting a high utility voltage condition. The loads receive normal power.

3.6"LINE NORMAL" indicator (GREEN LED)

The LED illuminates when the line input voltage is normal.

3.7 "BOOST AVR (VOLTAGE BOOST)" indicator (YELLOW LED)

The LED illuminates when the UPS is correcting a low utility voltage condition. The loads receive normal power.

3.8 LOAD bar graph

The display shows the power being drawn by the load.

3.9 POWER bar graph (BATTERY CHARGE/LINE VOLTAGE)

The display shows the present battery charge as a percentage of battery capacity. It also display the voltage of utility line.

3.10 "OFF" button

Press the OFF button to turn off the UPS and the loads.

REAR PANEL

3.11 TEL./MODEM SURGE PROTECTION

Surge protection for telephone and modem line to have the complete safety connection for INTERNET service.

3.12 EXTERNAL BATTERY PACK CONNECTOR (optional)

Caution: Use only factory supplied or authorized connecting cable for external

Image 6
Contents USER’S Manual Important safety instructions Please read this manualTable of contents Safety IntroductionPresentation Front PanelON/TEST button Yellow LED 11 TEL./MODEM Surge ProtectionInstallation Site Wiring Fault Indicators RED LEDComputer Interface Connect the telephone/modem lines Connect external battery pack optionalCharge the battery Connect to UtilitySwitch off Check the Site Wiring Fault IndicatorSwitch on OperationSilence Shutdown modeSelf-test Bttery charge bar graphAlarm Software optionsMaintenance Computer interface port has the following characteristicsComputer Interface Port Battery Replacement Storage conditions TroubleshootingStorage Extended storageBattery Pack Installation BlackSpecifications REDInterface Net Weight 18.0 23.5 26.1 28.4 Nominal Battery 48V 24V Voltage Built-in Charge Current

ls600A, 2000AL, 2500A, 3000A &1000AL, 1000A specifications

The Powercom 3000AL is a high-performance power distribution unit designed to support various electrical applications with exceptional efficiency and reliability. This model is particularly notable for its current capacities of 800A, 1250A, 1500A, and 2000A, offering significant versatility for different operational requirements.

One of the standout features of the Powercom 3000AL is its robust design, which ensures durability and longevity even in challenging environments. Built with high-quality materials, this power distribution unit can withstand extreme temperatures and potential mechanical stress, making it suitable for industrial, commercial, and institutional applications.

In terms of technology, the Powercom 3000AL employs advanced power management capabilities. It includes smart monitoring systems that enable real-time tracking of power consumption and performance. This functionality is invaluable for identifying inefficiencies or potential faults in the power distribution system, allowing for proactive maintenance and minimizing downtime.

Additionally, the unit is equipped with multiple protection features, including overload protection and short circuit protection. These safety measures ensure that the system remains operational under various load conditions while safeguarding connected equipment from damage.

The Powercom 3000AL also features modularity in its design, which allows users to customize and expand their power distribution setup based on evolving needs. This flexibility is essential for businesses that anticipate growth or fluctuations in their power requirements.

Furthermore, the unit incorporates energy-efficient technologies that reduce power loss, contributing to lower operational costs. It is compliant with international energy standards, emphasizing its commitment to sustainability and environmental responsibility.

Overall, the Powercom 3000AL with its capacities of 800A, 1250A, 1500A, and 2000A represents a reliable solution for high-capacity power distribution. Its combination of durable construction, advanced monitoring technology, safety features, and energy efficiency make it a valuable asset in any power management strategy. As industries continue to evolve, the versatility and dependability of the Powercom 3000AL ensure it meets the demands of modern energy usage effectively.