Wand Emulation

Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar.

Margin delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted.

Transmit delay: It is a delay time between barcode data output. It is the same as Block transmission delay of keyboard wedge.

Program

 

Option Bar Code

Option

Alphanumeric

 

 

 

 

Entry

 

 

 

 

 

 

 

 

620 pps

00

 

 

 

 

 

 

1250 pps

01

 

 

 

Output speed

2500 pps

02

 

 

 

5000 pps

03

 

 

 

10000 pps

04

 

 

 

20000 pps

05

 

 

 

 

 

 

 

*pps: pixel per

 

 

 

 

second

 

 

 

 

 

 

19

Image 19
Contents User’s Manual Contents Getting Started LGZ7225 Long Range Handheld CCD Spec Default Setting for each barcode shown as below Programming To program each option, you must Programming LGZ7225Exit Exit Interface SelectionKeyboard wedge Keyboard wedge USA Keyboard wedge 00-99 10 msec Block transmission Delay Flow control RS-232RTS/CTS Option Bar Code Alphanumeric Entry Bar/space polarity Wand EmulationWand Emulation Exit Scan Scanning modeTime 00-99 00-09 No double Double confirm Confirm Scan Exit Beep loudness/Beep tone freq./Beep tone duration You IndicationOption Bar Code Alphanumeric Entry Read Format UpcaExit UCC/EAN Upce Supplement digits Insertion group selection Refer to Insertion groupAuto detection Disable Enable EAN-13 Disable Enable ReadExit Format Data Digits Check Supplement Digits Or 5 or ISBN/ISSN EAN-8 Exit Supplement digits Format Code Code Id setting Refer to Code ID setting of Upca Exit Disable Enable Append Start/end Transmission Interleaved 2 Insertion group selection Refer to Insertion group Exit Industrial 2 Exit Program Option Bar Code Alphanumeric Entry Matrix 2 of 5 EurExit Codabar Exit ABCD/ABCD Code-128 00-64 Max. code length Min. code length UCC/EAN-128 Code-93 Exit Code-11 Exit MSI/plessey Exit UK/plessey Exit Telepen 1XPHULFRQO\ Standard 2 Exit China Post Exit Italian Pharmacode Exit String setting None Characters FfH Ascii String setting Exit Transmission Exit AIM ID Format of barcode data transmission 7HVW&KDUW  Page Ascii Code RWH  String setting list Parameter Setting ListProgram Barcode standard parameter setting list System parameter setting listFirmware version list Finish