Opticon LGZ 7225 user manual Scanning mode

Page 21

Scan

Scanning mode:

Good-readoff-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning.

Timeout off-The trigger button must be pressed to activate scanning, and scanner stops scanning when no code is decoded after the Stand-by duration elapsed. Continue-The scanner always keeps reading, and it does not matter when trigger button is pressed or duration is elapsed.

Same Barcode delay time: If the barcode has been scanned twice, then only the first barcode will be accepted.

Double confirm: If it is enabled, the scanner will require a several times successful decoding to confirm the barcode data. The more confirming times required the more inhibitive miss-reading code will be shown. If you set Double confirm, the Multi field scan Enable function won’t be able to work.

21

Image 21
Contents User’s Manual Contents Getting Started LGZ7225 Long Range Handheld CCD Spec Default Setting for each barcode shown as below Programming To program each option, you must Programming LGZ7225Exit Exit Interface SelectionKeyboard wedge Keyboard wedge USA Keyboard wedge 00-99 10 msec Block transmission Delay Flow control RS-232RTS/CTS Option Bar Code Alphanumeric Entry Bar/space polarity Wand EmulationWand Emulation Exit Scan Scanning modeTime 00-99 00-09 No double Double confirm Confirm Scan Exit Beep loudness/Beep tone freq./Beep tone duration You IndicationOption Bar Code Alphanumeric Entry Read Format UpcaExit UCC/EAN Upce Supplement digits Insertion group selection Refer to Insertion groupAuto detection Disable Enable EAN-13 Disable Enable ReadExit Format Data Digits Check Supplement Digits Or 5 or ISBN/ISSN EAN-8 Exit Supplement digits Format Code Code Id setting Refer to Code ID setting of Upca Exit Disable Enable Append Start/end Transmission Interleaved 2 Insertion group selection Refer to Insertion group Exit Industrial 2 Exit Program Option Bar Code Alphanumeric Entry Matrix 2 of 5 EurExit Codabar Exit ABCD/ABCD Code-128 00-64 Max. code length Min. code length UCC/EAN-128 Code-93 Exit Code-11 Exit MSI/plessey Exit UK/plessey Exit Telepen 1XPHULFRQO\ Standard 2 Exit China Post Exit Italian Pharmacode Exit String setting None Characters FfH Ascii String setting Exit Transmission Exit AIM ID Format of barcode data transmission 7HVW&KDUW  Page Ascii Code RWH  Program Barcode standard parameter setting list Parameter Setting ListSystem parameter setting list String setting listFirmware version list Finish