Proxim 5012-SUR manual Accessing the Command Line Interface, Ethernet Port

Page 20

Accessing the Command Line Interface

Ethernet Port

To use the CLI through the Ethernet port, you must have a telnet program, the CLI password, and the unit’s IP address.

To access the unit through Ethernet on a Windows PC:

1.Open a DOS command window: from the Windows Start menu, select Run; enter cmd.

2.In the DOS window displayed, enter the IP address (for example, telnet 10.0.0.1).

3.Click OK to start the telnet program; you are prompted for your password.

4.Enter the password (the default password is public).

Serial Port

In some cases, it may not be possible to retrieve the unit’s IP address. In this case, you can connect to the serial port by connecting to the unit through the serial port. You still need the CLI password of the unit. Proxim recommends you power off the radio and the computer before connecting or disconnecting the serial cable.

To access the unit through the serial port:

1.Start your terminal program.

2.Set the following connection properties; then connect:

COM port:

such as COM1 or COM2, to which the unit’s serial

 

port is connected

Bits per second:

9600

Data bits:

8

Stop bit:

1

Flow control:

None

Parity:

None

Line ends:

Carriage return with line feed

3.Disconnect and reconnect power to reset the unit. The terminal emulation program displays Power On Self Test (POST) messages. After approximately one minute (four minutes if DFS is enabled), you are prompted for your password.

4.Enter the default password public.

Page 20

Copyright © 2006 Proxim Wireless

Image 20
Contents Quick Install Guide Copyright TrademarksContents Key Features IntroductionPackage Contents Hardware and Software Installation Choose a location Attach cables All rights reserved Mount Unit to Pole All rights reserved View LEDs/Adjust Mounting Status Power Wireless Link Ethernet LinkClose Cable Compartment Assembly with the cable cover attached is shown below Tighten Band Clamps Install Documentation and Software Available from C\Program Files\Tsunami\MP.11 5012-SURSetting the IP Address InitializationCopyright 2006 Proxim Wireless Accessing the Web Browser Accessing the Command Line Interface Ethernet PortDefault Settings Setting DefaultNAT Hours of Operation Technical services and supportSupport Options