Raymarine ST60 Tridata manual Flush mounting, Surface mounting

Page 31

Chapter 3: Installation

19

Surface mounting

4

1

2

1

3

5

2

5

D4343-2

2.Apply the surface mount template (supplied at the rear of this hand- book) to the selected location and mark the centres for the fixing studs

(1) and the aperture (3) that will take the rear casing of the instrument.

3.Drill out the two 5 mm fixing stud clearance holes (2).

4.Cut out the clearance hole (3) then remove the template.

5.Peel off the protective sheet from the self-adhesive gasket (4) then stick the gasket into position on the rear of the instrument.

6.Screw the two fixing studs into the threaded sockets on the rear of the instrument.

7.Mount the assembled instrument, studs, bezel and gasket into the panel. Secure from behind with the thumb nuts (5).

Flush mounting

The Flush Mounting Kit uses a low-profile bezel to reduce the fitted profile of the instrument, to approximately 6 mm above the panel fascia.

Image 31
Contents ST60 Tridata Instrument Page Handbook information Safety noticesImportant information EMC conformancePage Contents Chapter Page Page Data inputs IntroductionSeaTalk Mounting options Remote controlStand alone operation Parts supplied Tridata Displayed information OperationGetting started Normal operationCurrent depth display DepthBoat speed Depth alarm threshold displaysAdjusting alarm thresholds SpeedAverage speed Maximum speedVelocity made good to windward Log TripTrip screen Water temperatureTimers Race-start timersDisplay settings AlarmsIllumination Contrast Instrument Maintenance and FaultfindingMaintenance Servicing and safetyCabling Fault findingPreliminary procedures Fixing faultsWorld wide web Technical supportTelephone help line Help us to help you Transducers InstallationPlanning your installation Site requirementsTransducer siting Instrument ST60 instrument dimensions EMC Installation GuidelinesConnections to Other Equipment Suppression FerritesSurface mounting ProceduresUnpacking Fitting the instrumentSurface mounting Flush mountingFitting the low-profile bezel Flush mounting procedure Bracket mounting Running transducer cable Fitting transducerSignal connections Connecting the instrumentTypes of connection SeaTalk systems Power supply connectionsStand alone instruments Speed readings CalibrationIntroduction User calibrationStarting User calibration Depth offset Depth unitsShallow alarm lock Set log units Set speed resolutionSetting the correct speed Set speed unitsUser calibration speed Timer alarm buzzer Adjust to SOGSet temperature units Temperature calibrationIntermediate calibration Speed calibration Page Calibration From Speed User calibration on/off Response settingsDealer calibration Leaving Intermediate calibrationDealer calibration Factory defaults Boat show modeLeaving Dealer calibration Page TOP Page Shaded area to be removed