Raymarine ST60 Tridata manual Flush mounting procedure

Page 33

Chapter 3: Installation

21

8

7

9

Fitting the low profile bezel

 

D4362-2

Flush mounting procedure

Flush mount your instrument (see the Flush mounting illustration) as follows:

1.Assemble the ST60 instrument and low-profile bezel as described under Fitting the low-profile bezel.

2.Ensure that:

The panel on which you intend to mount the instrument is between 3 mm and 20 mm thickness.

The selected location is clean, smooth and flat.

There is sufficient space behind the selected location to accom- modate the rear of the instrument and connectors.

3.Apply the flush mount template (supplied at the rear of this hand- book) to the selected location and mark out the aperture into which the assembled instrument and bezel will sit.

4.Cut out the aperture (3) for the assembled instrument and bezel and remove the template.

5.Peel off the protective sheet from the self-adhesive gasket (4) then stick the gasket into position on the rear of the bezel.

Image 33
Contents ST60 Tridata Instrument Page Important information Safety noticesEMC conformance Handbook informationPage Contents Chapter Page Page Introduction Data inputsSeaTalk Remote control Mounting optionsStand alone operation Parts supplied Tridata Getting started OperationNormal operation Displayed informationCurrent depth display DepthAdjusting alarm thresholds Depth alarm threshold displaysSpeed Boat speedMaximum speed Average speedVelocity made good to windward Log TripTimers Water temperatureRace-start timers Trip screenAlarms Display settingsIllumination Contrast Maintenance Maintenance and FaultfindingServicing and safety InstrumentPreliminary procedures Fault findingFixing faults CablingTechnical support World wide webTelephone help line Help us to help you Planning your installation InstallationSite requirements TransducersTransducer siting Instrument ST60 instrument dimensions EMC Installation GuidelinesConnections to Other Equipment Suppression FerritesUnpacking ProceduresFitting the instrument Surface mountingSurface mounting Flush mountingFitting the low-profile bezel Flush mounting procedure Bracket mounting Running transducer cable Fitting transducerConnecting the instrument Signal connectionsTypes of connection SeaTalk systems Power supply connectionsStand alone instruments Introduction CalibrationUser calibration Speed readingsStarting User calibration Depth offset Depth unitsShallow alarm lock Setting the correct speed Set speed resolutionSet speed units Set log unitsUser calibration speed Set temperature units Adjust to SOGTemperature calibration Timer alarm buzzerIntermediate calibration Speed calibration Page Calibration From Speed Dealer calibration Response settingsLeaving Intermediate calibration User calibration on/offDealer calibration Boat show mode Factory defaultsLeaving Dealer calibration Page TOP Page Shaded area to be removed