Raymarine ST60 Tridata manual Boat show mode, Factory defaults, Leaving Dealer calibration

Page 53

Calibration

41

Boat show mode

CAUTION:

Do NOT enable this mode. It must only be used for demonstration purposes.

Ensure that the Boatshow Mode Use is set to OFF. If necessary, use the trip or reset key to achieve this.

Factory defaults

You can use this screen to reset the operating parameters to the factory default values. If you want to apply the factory defaults, ensure the display shows YES, but if you want to retain the values you have set up, ensure that the display shows NO. Use the trip and reset keys to make the required selection.

The values you have selected will be applied when you exit this screen.

Leaving Dealer calibration

Hold down the depth and speed keys for 2 seconds to save your settings, exit Dealer calibration and resume normal operation.

Image 53
Contents ST60 Tridata Instrument Page Important information Safety noticesEMC conformance Handbook informationPage Contents Chapter Page Page SeaTalk IntroductionData inputs Stand alone operation Remote controlMounting options Parts supplied Tridata Getting started OperationNormal operation Displayed informationCurrent depth display DepthAdjusting alarm thresholds Depth alarm threshold displaysSpeed Boat speedVelocity made good to windward Maximum speedAverage speed Log TripTimers Water temperatureRace-start timers Trip screenIllumination AlarmsDisplay settings Contrast Maintenance Maintenance and FaultfindingServicing and safety InstrumentPreliminary procedures Fault findingFixing faults CablingTelephone help line Technical supportWorld wide web Help us to help you Planning your installation InstallationSite requirements TransducersTransducer siting Instrument ST60 instrument dimensions EMC Installation GuidelinesConnections to Other Equipment Suppression FerritesUnpacking ProceduresFitting the instrument Surface mountingSurface mounting Flush mountingFitting the low-profile bezel Flush mounting procedure Bracket mounting Running transducer cable Fitting transducerTypes of connection Connecting the instrumentSignal connections SeaTalk systems Power supply connectionsStand alone instruments Introduction CalibrationUser calibration Speed readingsStarting User calibration Depth offset Depth unitsShallow alarm lock Setting the correct speed Set speed resolutionSet speed units Set log unitsUser calibration speed Set temperature units Adjust to SOGTemperature calibration Timer alarm buzzerIntermediate calibration Speed calibration Page Calibration From Speed Dealer calibration Response settingsLeaving Intermediate calibration User calibration on/offDealer calibration Leaving Dealer calibration Boat show modeFactory defaults Page TOP Page Shaded area to be removed