Telenetics DSP9612RM manual SW2-1 − Fast Poll/FSK high- & low-speed modes

Page 16

Installation

SW2-1 − Fast Poll/FSK (high- & low-speed modes)

SW2-1 ON = Low-Speed Mode (FSK)

OFF = High-Speed Mode (Fast Poll)

SW2-1 configures the modem for either low-speed (FSK) mode or high-speed (Fast Poll) mode. As a result, the SW2-1 setting you choose determines the switch definitions for the other switches.

cFor high-speed mode, the configuration switches follow the definitions in Table 2-1.

cFor low-speed mode, the configuration switches follow the definitions in Table 2-3.

SW2-4 − Auto RTS (high-speed mode only)

SW2-4 ON = Enable Auto RTS

OFF = Disable Auto RTS

For data terminals that do not support hardware RTS, set SW2-4 to ON to enable buffer mode. In this mode, TXD is detected at the modem and internal RTS is turned ON. After training completes, the TXD is transmitted to the remote modem. The transmitter turns off if no TXD is detected after 1 character length of idle time.

SW2-6 − Production Test Only (high- & low-speed modes)

SW2-6 Must be OFF

SW2-6 must be in the OFF position for normal operation.

SW2-72-/4-Wire Operation (high- & low-speed modes)

SW2-7 ON = 2-Wire, Half-Duplex Mode

OFF = 4-Wire, Full-Duplex Mode

SW2-7 configures the modem for 4-wire full-duplex or 2-wire half- duplex operation.

Page 16

Image 16
Contents DSP9612RM Flash Poll Rack-Mount Modem User’s Guide Compliances Contents Contents Chapter Introduction Features Applications Ancillary DocumentationIntroduction Unpacking Your Hardware Chapter InstallationAdditional Items You Need Hardware Overview Front View of ModemComponent View Installation Summary Configuring the Modem Configuring the Modem SW1-1 through SW1-4 − Transmit Level high- & low-speed modes SW1-5 − Receiver Dynamic Range high- & low-speed modes SW2-1 − Fast Poll/FSK high- & low-speed modes SW2-8 − Carrier Control high- & low-speed modes Low-Speed FSK Mode SW1-1 through SW1-4 Switch Settings SW1-6 and SW1-7 − RTS-CTS Delay low-speed mode only SW2-2 − CD Delay low-speed mode only SW2-5 − Soft Carrier low-speed mode only Installing the Modem in the Universal Data Shelf Installing the Modem in the Universal Data ShelfInstalling the Modem Connecting to a Transmission Line Modular Jack ConnectorsConnecting an RS-232 Device LEDs DLBLoopback Control Switch Illustrates these three diagnosticsAppendix a Troubleshooting Problem SolvingPage Appendix B Specifications General SpecificationsMechanical Specifications Back-to-Back Connections to a Second Modem RS-232 RTU InterfaceEnvironmental Specifications CompliancesAppendix C Limited Product Warranty Appendix D RMA Procedure Return Merchandise Authorization RMA Procedure