MECHANICAL INSTALLATION 110SR

6)Leave some excess wire hanging through the opening in the PIR so the drywall contractors can cut a locate hole and drop the wires through. You may also want to consult with them on cutting out the opening for the sub as they will likely have the power tools (Fig. 11) necessary to quickly and accurately cut out the opening (Fig. 5).

7)If you are inexperienced, but plan on doing this yourself, the job can be made easier by proceeding in two steps.

1)“Hog” out the major inside portion of the material (Fig. 5).

2)Carefully cut out the recess for attaching the subwoofer (Fig. 6).

8)A word about the Rotozip™ tool for cutting holes in wallboard: using the correct bit, and accurately setting the cutting depth will greatly reduce any errors caused by the tool “getting away” or cutting into the PIR. Use only a Guidepoint™ bit as pictured (Fig. 11); it will follow the inside perimeter of the PIR. For the first cut, set the depth to the thickness of the wallboard plus 5/8” (the thickness of the PIR). Example: 5/8” PIR plus 5/8” wall board equals 1-1/4” cutting depth.

9)After the majority of the material has been removed from the center of the PIR, you can set the cutting depth for the second step. Holding the tool up to the opening, set the depth gauge so that the Guidepoint™ bit will now follow the recessed cutaway in the PIR.

Figure 5: Cutting drywall using the Rotozip™ .

Figure 6: Completed install showing the reveal of PIR relative to the ceiling board.

Figure 7: Installing the subwoofer using the ledge to temporarily secure it.

Figure 8: Attaching the subwoofer to the PIR.

Image 18
Contents Series Subwoofers WARRANTY/DAMAGE Claims UNPACKING-DAMAGE ClaimsSeries Subwoofers and Input Modules 110TB Tile Bridge 110SR Sheet RockPage Table of Contents 110SR Sheet Rock Cabinet Cabinet Options110TB Tile Bridge Cabinet 110CS Corner Subwoofer CabinetInput Module Options Passive standardCrossover Passive 70 Volt with crossover Active active subwoofer with 2-channel feed-through Active input module is UL and CSA listedActive 110 Input Module Controls Active Module with output for 2 speakersActive 110 Input Module Controls Mechanical Installation 110TB NEW / Existing Construction Installation Procedures’ x 2’ Tile Grid Installation Procedures Installed subwoofer top view, only two chains attached Suspension points Mechanical Installation 110SR Instalation of blocking for flush mounting of PIR to joists Cutting drywall using the Rotozip SR installation Mechanical Installation 110CS Installation of Corner Rail KITSubwoofer Installation Mechanical Installation 110CS Dimensions 110TB 40 LBSDimensions 110SR 37 LBSDimensions 110CS 56 LBSTechnical Specifications Active Module Ceiling & IN-WALL Loudspeakers 0903