Sega 999-0988, Star Wars Racer Arcade owner manual Monitor, Primary side and secondary side

Page 61

12. MONITOR

12 - 1 CAUTIONS AND WARNINGS CONCERNING THE SAFETY FOR HANDLING THE MONITORS

When performing such work as installing and removing the monitor, inserting and disconnect- ing the external connectors to and from monitor, be sure to disconnect the power connector (plug) before starting work. Proceeding the work without following this instruction can cause electric shock of malfunctioning.

Using the monitor by converting it without obtaining a prior permission is not allowed. SEGA shall not be liable for any malfunctioning and accident caused by said conversion.

Primary side and secondary side

The monitor’s circuit which is divided into the Primary side and secondary side, is electrically isolated. Do not touch the primary side and the secondary side simultaneously. Failing to observe the instruction can cause electric shock, and this is very dangerous. When making monitor adjustments, use a non- conductive driver and make adjustment without touching any other part other than the Adjustment V.R. and Knob. Also, be sure not to cause a short- circuit to the Primary side and the Secondary side. If short-circuited, it can cause electric shock or mal- functioning, which is very dangerous.

High tension Voltage

Some of the parts inside the monitor are subject to high-tension voltage in excess of 20,000 volts and very dangerous. Therefore, do not touch the monitor interior. Should soldering & paper wastes, etc. be mixed in the monitor, turn the power off so as not to cause malfunc- tioning or fire hazard.

Connecting the CRT and PCB

For combining the CRT and PCB, use the specified part No. to maintain the status of adjust- ments made at the factory. The anode of the CRT itself will be accumulitavely charged as time elapses, generating high tension voltage which is very dangerous. The monitor should be used with the Chassis, CRT and PCB assembled. When repair, etc. is required at the time of malfunc- tioning, be sure to send it in an “as assembled” condition. If these are disassembled, what’s charged to said high tension voltage can be discharged, causing a very hazardous situation. Therefore, under no circumstances should it be disassembled.

Static Electricity

Touching the CRT surface sometimes causes you to slightly feel electricity. This is because the CRT surfaces are subject to static and will not adversly affect the human body.

Installation and removal

Ensure that the Magnetizer Coil, FBT (Fly-Back Transformer), Anode Lead and Focus Lead are not positioned close to the sheet metal work’s sharp edges, etc. and avoid damaging the insulated portions so as not to cause an electric shock and malfunctioning. (For the name of parts, refer to the above figures.)

59

Image 61
Contents Mini DX Warranty Page Page Sega ENTERPRISES, INC. USA General Precautions Installation Precautions Precautions to be Heeded for Operation Precautions to be Heeded During Operation Name of Parts KEY Description KEY Master AccessoriesTamperproof Wrench ToolNever Ship Hikaru Game Boards Outside of Cage Assy of Cabinet Assembling and InstallationSecuring in Place Adjuster Adjustment Power Supply Memory Test Assembling CheckInput Test Sound TestOutput Test Precautions to be Heeded When Moving the Machine Contents of Game HOW to Play For Communication Play SMUGGLER’S Cove Normal Bantha Tracks EasyPixelito Challenge Hard Boonta Classic ExpertBrake and Lever Used jointly Game Screen Name Entry Password System Test Mode Switch Unit Switch Unit and Coin MeterSpeaker Volume Speakers Speaker Volume Super WooferRAM Test System Test Mode MenuJVS Test R.T. Test Sound TestIndividual System AssignmentsCommon Seat Number Coin Assignments Setting Example Manual SettingCoin to Credit Bonus Adder Coin Chute #1 Multiplier COIN/CREDIT Setting Setting No Coin Counts AS Multiplier Coins Each SEAT’S Coin ChuteSequence Setting Bookkeeping Backup RAM Clear Rombd Test Game Test Mode Clock SettingGame Menu Game Test ModeInput Test Recommended Volume ValueOutput Test This case the cabinet is set to Slave Game AssignmentsThis case the cabinet is set to no Link Play Time Number of GamesTime Histogram Calibration Test Features Backup Data ClearControl Panel Grip END 10 1 Removing the Control Panel CoverGrip PIN Grip10 2 Volume ADJUSTMENT/REPLACEMENT AdjustmentVolume ReplacementApply Greasing to the Assy Mecha Lever 10 3 GreasingApply Greasing to the Assy Brake Handling the Coin JAM Coin SelectorHole Position Optional Dollar Bill AcceptorPage Coin door shown with optional dollar bill validator inserted Primary side and secondary side Monitor12 2 Cautions to be Heeded When Cleaning the CRT Surfaces 12 3 Adjustment Method Fluorescent Lamp Replacing the Fluorescent Lamp and ButtonsStart Button and View Change Button Periodic Inspection Table Cleaning the Cabinet SurfacesDesign Related Parts SW Brkt Parts List Switch UnitSticker SW Unit VOL Cont B-5K OHMAssy AC Unit DRT1-0400 Assy Seat Assy Controller Assy Lever Mecha Start Switch IMPERIAL#57-2000-30Boost Button IMPERIAL#54-0004-12 Assy BrakeAssy Lever Mecha Front ViewLever Brkt Inner Adjust GearLever Shaft Stopper Rubber LeverDisk Inner Rory Dampr STW Mini Spring Rotary Dampr STW Mini Item no Description Wire Color Table Visit OUR Website