How Squelch Works

Think of “SQUELCH” as a gate. If the gate is too low (squelch too low), everything (all noise as well as signals) gets through.

If the gate is set too high (squelch too high), nothing gets through.

If the gate is set just right (squelch set properly), just the desired signals get through.

Setting the Squelch

467.8500

1.

To set the squelch, press HOLD/RESUME to stop

 

scanning.

 

2.

Turn SQL fully counterclockwise until hiss heard.

 

 

This lowers the “squelch gate,” allowing all signals and

 

 

noise to get through.

 

3. Turn SQL fully clockwise just until hiss stops.

This raises the “squelch gate,” allowing only strong signals to get through.

14

UBCT9 OM 14

12/11/07 3:53:32 PM

Image 18
Contents UBCT9 Scanner Precautions Contents Edacs Range Mhz Mode Step IntroductionFront and Rear Views Selector SQL, FlashIcon Display Number 1 2 3 4What is Trunk Tracking? What is Scanning?What is Searching? TerminologyUBCT9 OM Feature Highlights Optional Accessories Included with Your Scanner PackageInstalling the UBCT9 For Home Use Desktop InstallationFor Mobile Use In-Car Installation Connecting the Power Cord Installation for everyday use Typical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation DC power InstallationConnecting the Clone Cable Applying Power Using Standard AC PowerConnecting an External Speaker Listening SafelyScanning Overview Turn the Scanner OnSetting the Squelch How Squelch WorksState Scanning Selecting the StatePress Police State Scan Hold Storing State Scan FrequenciesSkip a frequency Set Close Call Mode Close Call RF CaptureClose Call Operation Set Close Call Option Select Close Call BandsAlert Light Adjustment Setting of pager screenAlert Tone Volume Set Close Call AlertPrivate Bank Scanning Programming Frequencies into ChannelsDeleting a Stored Frequency Duplicate Frequency Alert Memory LockScanning Private Bank Restoring a Locked-out Channel in Hold Mode Hold/ResumeChannel Lockout Changing the Priority Channel Restoring All Locked-out ChannelsPriority Scan Then press HOLD/RESUMEService Scanning Police Rail Roads Aircraft Marine Band UHF CB BandBand Search Setting a Search BandMode Step Display Band NoSearch Hold Feature Data SkipFrequency Skip Delay Storing Search FrequenciesTrunk Tracking Programming Trunking Frequencies Selecting Trunking System TypeProgramming Trunking Frequencies Programming Talk Group ID/Scan ListsTo enter a Full Edacs ID To enter a Type 2 Talk Group IDTo enter a Type 1 ID To enter a Partial Edacs IDID Scan Mode Receiving Trunked SystemsID Scan Hold Feature ID Search ModeTo directly access a specific ID location Programming Scan Lists During Search ID Monitor ModeID Search Hold and Direct Entry ID in Hold Mode Deleting a Stored IDID Lockout To restore a single ID, follow these stepsTo restore all locked out IDs in a bank once Review ID LockoutTrunking Frequency Confirmation Setting the Delay Mode for Trunking ModeSetting Priority in Trunking Mode Moving between Scan List MemoriesMulti-Track Multi-Track Operational DetailsEdacs Reception Edacs TrackingProgramming Edacs System Frequencies An Edacs Trunked system FormatSpecial Edacs Features Edacs ID Range SearchLTR Reception LTR TrackingMotorola Reception Motorola TrackingSelecting Preset Fleet Map Fleet Map ProgrammingProgramming a User Fleet Map Programming a Hybrid System Control Channel Only Mode Toggling the Status BitDisconnect Tone Detect Option End Code PC Control Mode Remote InterfaceClone Mode PC Control ParameterFor your information To connect the Scanner to Scanner 12/11/07 35404 PM Care and Maintenance General UseTroubleshooting Problem Suggestion12/11/07 35405 PM Specifications Appendix State Code Order State NamePreset Fleet Maps 12/11/07 35407 PM User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code Restrictions Memo Memo One Year Limited Warranty Uniden UBCT9 Scanning ReceiverFax 02 9599 Fax 09 274 Thank YOU for Buying a Uniden Product