Uniden UBCT9 manual Storing Search Frequencies, Delay

Page 32

Storing Search Frequencies

You can quickly store any frequency you find during Search.

1. During Search, press HOLD/RESUME. If you want to change the frequency, use the or key to move up or down 1 frequency step. Then press E. Or when the scanner stops on the frequency you want to store, press E.

2.Select a bank you want to store by using the keypad. The smallest empty channel number and the

frequency alternately appear on the display. If necessary, you can also change the channel by using the keypad, the or key.

3. Press E.

Note: • If the frequency you want to store exists already in a bank, you will hear an error tone and other channel appears on the display. (See “Duplicate Frequency Alert” on page 22.)

After storing the frequency, it moves to the Search Hold mode.

If there is no free channel, the frequency you want to store will automatically be stored in the first channel in the selected bank.

4.Press to resume searching.

Delay

To help prevent missing a reply on a specific channel or frequency, you can program a two second delay into any channel, frequency, service band or band search. When scan or search stops on a channel or frequency, there is a two-second pause before the scanning cycle resumes.

To activate the Delay feature (in either Scan mode or Search mode):

1.For State Scan mode or Private Scan mode, when in Hold mode, select the desired frequency or channel and then press DELAY. Or when the scanner stops on an active frequency or channel, quickly press DELAY before it continues scanning again.

––– OR –––

1.For Search mode, while searching press DELAY.

2.DLY ” will appear on the display.

28

UBCT9 OM 28

12/11/07 3:53:45 PM

Image 32
Contents UBCT9 Scanner Precautions Contents Edacs Range Mhz Mode Step IntroductionFront and Rear Views Selector SQL, FlashIcon Display Number 1 2 3 4What is Scanning? What is Searching?What is Trunk Tracking? TerminologyUBCT9 OM Feature Highlights Optional Accessories Included with Your Scanner PackageFor Mobile Use In-Car Installation Installing the UBCT9For Home Use Desktop Installation Connecting the Power Cord Installation for everyday use Typical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation DC power InstallationApplying Power Using Standard AC Power Connecting an External SpeakerConnecting the Clone Cable Listening SafelyScanning Overview Turn the Scanner OnSetting the Squelch How Squelch WorksPress Police State ScanningSelecting the State Skip a frequency State Scan HoldStoring State Scan Frequencies Set Close Call Mode Close Call RF CaptureClose Call Operation Set Close Call Option Select Close Call BandsSetting of pager screen Alert Tone VolumeAlert Light Adjustment Set Close Call AlertDeleting a Stored Frequency Private Bank ScanningProgramming Frequencies into Channels Scanning Private Bank Duplicate Frequency AlertMemory Lock Channel Lockout Restoring a Locked-out Channel in Hold ModeHold/Resume Restoring All Locked-out Channels Priority ScanChanging the Priority Channel Then press HOLD/RESUME Service Scanning Police Rail Roads Aircraft Marine Band UHF CB BandSetting a Search Band Mode Step DisplayBand Search Band NoFrequency Skip Search Hold FeatureData Skip Delay Storing Search FrequenciesTrunk Tracking Programming Trunking Frequencies Selecting Trunking System TypeProgramming Trunking Frequencies Programming Talk Group ID/Scan ListsTo enter a Type 2 Talk Group ID To enter a Type 1 IDTo enter a Full Edacs ID To enter a Partial Edacs IDID Scan Mode Receiving Trunked SystemsTo directly access a specific ID location ID Scan Hold FeatureID Search Mode ID Monitor Mode ID Search Hold and Direct Entry ID in Hold ModeProgramming Scan Lists During Search Deleting a Stored IDTo restore a single ID, follow these steps To restore all locked out IDs in a bank onceID Lockout Review ID LockoutSetting the Delay Mode for Trunking Mode Setting Priority in Trunking ModeTrunking Frequency Confirmation Moving between Scan List MemoriesMulti-Track Multi-Track Operational DetailsProgramming Edacs System Frequencies Edacs ReceptionEdacs Tracking An Edacs Trunked system FormatSpecial Edacs Features Edacs ID Range SearchLTR Reception LTR TrackingMotorola Reception Motorola TrackingProgramming a User Fleet Map Selecting Preset Fleet MapFleet Map Programming Programming a Hybrid System Control Channel Only Mode Toggling the Status BitDisconnect Tone Detect Option End Code PC Control Mode Remote InterfaceFor your information Clone ModePC Control Parameter To connect the Scanner to Scanner 12/11/07 35404 PM Care and Maintenance General UseTroubleshooting Problem Suggestion12/11/07 35405 PM Specifications Appendix State Code Order State NamePreset Fleet Maps 12/11/07 35407 PM User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code Restrictions Memo Memo Fax 02 9599 Fax 09 274 One Year Limited WarrantyUniden UBCT9 Scanning Receiver Thank YOU for Buying a Uniden Product