3M 800af manual Initial Start-Up of Case Sealer, Pneumatic Connection

Page 19

Installation and Set-Up (Continued)

11.Box size capacity (height) – at its factory setting, the case sealer handles box sizes up to 620 mm

[24-1/2 inches] maximum height. If larger capacity is needed, the machine can be adjusted to accommodate up to 725 mm [28-1/2 inches] high boxes. Refer to "Special Set-Up Procedure – Outer Column Re-Positioning", page 35 for set-up information.

12.Drive Belt Height – drive belt assemblies can be raised 50 mm [2 inches] to provide better conveying of tall boxes. Refer to "Special Set-Up Procedure – Changing Drive Belt Height", page 33.

13.Pneumatic connection.

WARNING – USE CARE WHEN WORKING WITH COMPRESSED AIR.

The case sealer requires a 6.5 bar gauge pressure [95 PSIG] 75 liter/min @21°C, 1.01 bar [2.5 SCFM] compressed air supply. As shown in Figure 2-3 an on/off valve, pressure regulator, and filter are provided to service the air supply.

The main air supply line should be connected to the on/off valve by means of the barbed fitting and hose clamp provided on the outer side of the on/off valve as shown in Figure 2-3. The customer supplied air hose (5/16 inch [8 mm] ID) should be slipped over the barbed fitting and clamped tightly in place.

If another type of connector is desired, the fitting can be removed and replaced with the desired 1/4-18 NPT threaded connector.

Always turn the valve "Off" when air supply line is being connected or disconnected.

14.Electrical connection and controls – the electrical control box shown in Figure 3-1, contains the "On/Off" switch with pre-set breaker and can be located on either side of the machine frame for operator convenience. A standard three conductor power cord with plug is provided at the back of the electrical control box for 115 Volt, 60 Hz, 3.8 Amp electrical service. The receptacle providing this service shall be properly grounded. Before the power cord is plugged into 115 Volt, 60 Hz outlet, make sure red "Off" button is depressed and that all packaging materials and tools are removed from the machine. Do not plug electrical cord into outlet until ready to run machine.

Note – Machines outside the U.S. may be equipped with 220/240 Volt, 50 Hz systems, or other electrical requirements compatible with local practice.

Initial Start-Up of Case Sealer

 

After completing the "Set-Up" procedure, continue

 

through ""Operation", pages 15-24 to be sure case

Figure 2-3 – Pneumatic Connection

sealer is properly adjusted to run product.

14

Image 19
Contents AccuGlideTM To Our Customers Replacement Parts and Additional ManualsTo Our Customers 800af Adjustable Case Sealer Type Table of ContentSection II AccuGlide STD 2 Inch Taping Heads Intended Use 3M-Matic800af Adjustable Case Sealer, TypeContents 800af Adjustable Case Sealer Knife Warning Label Important SafeguardsMoving Flap Kicker Safety Instructions Label 13 Permissible Lift Area Label Power Requirements SpecificationsOperating Rate Tape Roll Diameter Operating ConditionsTape Tape WidthBox Weight and Size Capacities Maximum Machine Dimensions MinimumSet-Up Recommendations Receiving And Handling Installation and Set-Up Machine Set-Up Installation and Set-Up Conveyor Systems Pneumatic Connection Initial Start-Up of Case SealerCase Sealer Components OperationMain Air On/Off Valve/Pressure Regulator/Filter -3 Controls, Valves and Switches Electrical On/Off SwitchTop Flap Compression Rollers Height Adjustment Crank, Upper Taping HeadWidth Adjustment Crank Indicator, Air PressureSee Section II, Pages 7 Box Size Set-Up Operation Passing through machine to avoid injury Machine before operating11 Box Size Set-Up Feeding boxes to the machine13 Box Size Set-Up Occur Box SealingBox Jams Turn machine On only when it is safe to do soLubrication MaintenanceDrive Belt Replacement Damage Drive Belt Replacement/Tension AdjustmentDrive Belt Tension Adjustment Top View Equipment damage Air Line Filter -5 Knife Replacement, Taping HeadCircuit Breaker Taping Head Adjustments -Refer to Section AdjustmentsDrive Belt Tension Damage Upper Taping Head Leveling Gate Stroke Setting This page is Blank Drive Belt Height, Disassembly Special Set-Up ProcedureTaping Heads Outer Column Re-Positioning Refer to Figure Column Re-Positioning Troubleshooting Guide Problem Cause Correction TroubleshootingTroubleshooting Pneumatic Diagram Pneumatic DiagramElectrical Diagram Electrical DiagramPage This page is Blank Spare and Miscellaneous Parts Part Number Option/Accessory Options/AccessoriesReplacement Parts Illustrations and Parts Lists This page is Blank 800af Adjustable Case Sealer Frame Assemblies 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 1of Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Ref. No 3M Part No Description 800af Adjustable Case Sealer Safety and Information Labels Ref. No 3M Part No Description Qty