Operation (Continued)
Figure 3-3 – "On/Off" Valve/Regulator/Filter
3Emergency "Stop" Switch
The two emergency "Stop" switches are mounted for operator convenience, on both sides of the case sealer. Pushing either of these switches will stop the drive motors/belts and exhaust air from the flap kicker.
To restart machine, rotate emergency stop switch (release switch latch) and then restart machine by pressing green (On) button on side guard.
4Height Adjustment Crank, Upper Taping Head
Raises and lowers upper taping head/flap folders to accommodate box height.
5Width Adjustment Crank
Adjusts distance between side drive belts to accommodate box width.
6Top Flap Compression Rollers
Rollers adjust to properly maintain box width/ top flap center seam for tape seal.
7Indicator, Air Pressure
The optical warning indicator, located on the upper flap folder frame, indicates "Red" when compressed air circuit is on.
8Box Gate Air Pressure Regulator
Adjusts lifting force of the box gate depending on the weight of boxes being sealed.
9 Gate Cams Figure
The gate cams A B control the rate of box entry into the case sealer. Depending on box size, gate cams can be adjusted to increase production rate. See "Adjustments – Gate Operation", page 29.
10Kicker Cam Figure 3-4
The minor flap folder, controlled by the kicker cam C , closes the trailing minor flap on the box. The kicker cam must be adjusted according to the length of the box being sealed. See "Operation", page 20,
Figure
11Pocket, Instruction Manual
A pocket is provided inside the right door for storage of the machine instruction manual. Keep the manual in this pocket for the convenience of machine operators.
Figure 3-4 – Gate/Kicker Cams