Operation (Continued)
Figure 3-2 – Controls, Valves and Switches
1Electrical "On/Off" Switch
The box drive belts are turned on and off (off button is red) with the electrical switch on the side of the machine guard at the infeed end.
Note
2Main Air "On/Off" Valve/Pressure Regulator/Filter –Figure 3-3
This set of pneumatic components controls, regulates and filters plant air supply to the two separate control circuits of the case sealer.
"On/Off" Valve
Always turn the air "Off" when machine is not in use, when servicing the machine, or when connecting or disconnecting air supply line.
Note – The air valve has provisions for lockout/tagout according to plant regulations.
Pressure Regulator regulates main air pressure to the machine to adjust pressure, pull knob up and turn – push down to lock setting.
Filter removes dirt and moisture from plant air before it enters the case sealer pneumatic circuits. If water collects in bottom of bowl, lift up on the valve on the bottom of bowl to drain.
16