Panasonic VL-GM001 Wiring schematic diagram, Power cable/wire type and distance

Page 9

Introduction and Installation

Wiring schematic diagram

All monitor stations and sub monitor stations should be connected by daisy chain wiring method.

The connection of 2nd sub monitor station (the last end terminal) and monitor station is NOT required.

Connect to terminals H11 and H12 of the monitor station.

Sub Monitor station VL-GM001A

H11

H12

H21

H22

K1

K2

AC adaptor

Chime

120 V AC

Connect to terminals H21 and H22 of the sub monitor station.

NOTE:

This chime wiring schematic diagram is only an example.

Refer to the wiring instruction provided with your chime for detail.

Refer to the technical data on page 18 when connecting to a chime.

All connections are non polar.

Power cable/wire type and distance

Power cable (between the sub monitor station and the AC adaptor): Type: ø1.2 Fire alarm cable 16 AWG

Distance: Maximum 30 m (about 98 feet)

Wire (between the monitor station and the last sub monitor station): Type: General cable CAT-3 24 AWG

Distance: Maximum 100 m (about 328 feet)

9

Image 9
Contents Installation and Operation Guide Important Information Introduction and InstallationHelp General InformationDo not Open Important safety instructionsAdditional safety information For best performance Quantity Included itemsLocation of controls Standard installation position of the sub monitor station Before installationPower cable/wire type and distance Wiring schematic diagramInstalling the sub monitor station Installation size Inside of main unit bottom case Remove the front case from the bottom case Introduction and Installation To attach the AC adaptor and the DC terminal to a wall Correct Incorrect To attach the wires To attach the power cable Sub Monitor station DC terminalImportant information CleaningTechnical data about this product Page For your future reference Panasonic Puerto Rico, IncCopyright