Panasonic LC2H Specifications, Installation frame type Standard type, PC board mounting type

Page 3

LC2H

2)Installation frame type

1 Standard type

No. digits

Counting speed

Front reset

Input method

Part No.

 

2 kHz/30 Hz switchable

 

Non-voltage input type

LC2H-F-2KK

 

 

 

 

8 digits

Yes

Voltage input type (4.5 to 30 V DC)

LC2H-F-DL-2KK

 

 

30 Hz

 

Free voltage input type (24 to 240 V AC/DC)

LC2H-F-FV-30

 

 

 

 

 

Note) Please ask us about types without front resetting.

2 Backlight type

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz/30 Hz switchable

Yes

Voltage input type (4.5 to 30 V DC)

LC2H-F-DL-2KK-B

 

 

 

 

 

2. PC board mounting type

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz

No

Non-voltage input type

LC2H-C-2K-N

30 Hz

LC2H-C-30-N

 

 

 

 

 

 

 

 

Specifications

1. Panel mounting type

Type

Standard type

 

Backlight type

Standard type

Item

Non-voltage input

Voltage input

 

Free voltage type

No. digits

 

 

8 digits

 

External power supply

 

 

Not required (built-in battery)

 

Max. counting speed

2 kHz/30 Hz (Switchable by switch)

30 Hz (Note 2)

 

Min. input signal width

0.25 ms/16.7 ms (Switchable by switch)

16.7 ms

 

(ON: OFF = 1:1)

 

 

 

 

 

 

 

 

Non-voltage input using

 

 

 

High level:

 

 

 

High level: 4.5 to 30 V DC

24 to 240 V AC/DC

 

Input method (signal)

contacts or open collector

 

 

 

Low level: 0 to 2 V DC

Low level:

Count

 

connection

 

 

 

 

 

0 to 2.4 V AC/DC

input

 

 

 

 

 

 

When shorted:

 

 

 

 

 

 

 

 

 

 

 

Input impedance

Max. 10 k

 

Approx. 4.7 k

 

When open:

 

 

 

 

 

 

 

 

 

Max. 750 k

 

 

 

 

 

Residual voltage

Max. 0.5 V

 

 

Min. input signal width

 

 

200 ms

 

 

 

Non-voltage input using

 

High level: 4.5 to 30 V DC

Non-voltage input using

 

Input method (signal)

contacts or open collector

 

contacts or open collector

 

 

Low level: 0 to 2 V DC

 

 

connection

 

connection

Reset

 

 

 

 

 

When shorted:

 

 

 

When shorted:

input

 

 

 

 

 

Max. 10 k

 

 

 

Max. 10 k

 

Input impedance

 

Appox. 4.7 k

 

When open:

 

When open:

 

 

 

 

 

 

 

Max. 750 k

 

 

 

Max. 750 k

 

Residual voltage

Max 0.5 V

 

Max. 0.5 V

Display method

7-segment LCD

 

7-segment LCD

7-segment LCD

 

With green/red backlight

 

 

 

 

 

 

 

 

 

 

 

 

Between charged and

Breakdown voltage (initial)

Between charged and uncharged parts: 1,000 V AC for 1 minute.

uncharged parts: 2,000 V

 

 

 

 

 

 

AC for 1 minute.

Insulation resistance (initial)

Min. 100 M(measured at 500 V DC) Measurement location same as for break down voltage.

Backlight power

 

24 V DC (±10%)

Protective construction (Note 3)

IEC Standard IP66 (only panel front: when using rubber gasket)

Accessories (Note 3)

 

 

Rubber gasket, mounting bracket

 

Battery life

7 years (at 25°C 77°F) Note 1

6 years (at 25°C 77°F)

Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed. Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode.

2.Operation is at 25 Hz when using 24 V AC.

3.Only for installation frame type.

99

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Image 3
Contents Timers/Time Switches/Counters/Hour Meters Features Product chartProduct types Installation frame type Standard type SpecificationsPC board mounting type Applicable standard Common100 Part names DimensionsTerminal layout and wiring diagrams 1 Standard type Installation frame typePanel mounting diagram Panel cut-out dimensionsStandard type PC board mounting type External dimensionsTerminal layout and wiring diagrams Input methodExplanation of operation Backlight type104 Environment for use Voltage input typeFree voltage input type Voltage input type Backlight luminanceATH3803 RoHS Directive compatibility information106 One shot/over count One shot/recount Options Mounting frame107 Lock switch Front reset keyMode key Setting keyBacklight setting mode How to setPreset value setting mode Lock modeCompliance with the CE marking Output setting mode This sets the operation mode111 Operation modeSelf-diagnosis function Input and output connectionInput connection Contact input As PNP outputInsulation sheet LC2H total counter one-touch installation typeLC2H total counter installation frame type LC2H preset counterOptions Accessories for LC2H total counterLithium battery 3 Installation parts Mounting frameLCD AEL3Typical Counter Applications COUNTER-RELATED Terminology Connection of input Except for LC4H-S/AC type Protective circuit for counter contactLeakage current Installing the counterSuperimposed surge of power supply Signal input143 Sockets Unit mm inch, Tolerance ±1 ±.039Accessories Mounting partsPanel cover Black Installing DIN Size Counter Installation methodsSurface mount 180 AttachmentCDX S1DXM-/S1DX PM48W PM4H-WPM48W PM4HW PMH-M PM4H-M/PM4S PMH-M PM4HM-/PM4SLC4H EM48S LC4H-L LC4HLC4H MC6 LC4H-L LC48W LC4H-WForeign Specifications Overview 120 800 180 240 Voltage Current Power During Input120 200 720 240 Pilot Duty B300 AC applied 120 600 360 240 Pilot Duty C300 AC appliedForeign Specifications LC4H-W Pilot Duty C300 CountersHour Meters LC4H-L Pilot Duty C300 LC4H-SAppropriate CE Markings OverviewCounter, Hour Meter conforming to EN/IEC standards CE markings and EC directives