Panasonic LC2H specifications Typical Counter Applications

Page 20

TYPICAL COUNTER APPLICATIONS

The highly accurate, reliable counters can be controlled from the front panel and are suitable for a wide range of applications.

DOWN and HOLD-A modes

for shipment quantity counting

Photoelectric

 

switch

Motor

 

(stop/start)

Shipment quantities are counted to con- trol the conveyor line flow.

UP and SHOT-A modes

for packing a specified number of copies

Electric counter

Motor

Photoelectric switch

Printing machine

Printed matter is counted to package a specified number of copies.

UP and SHOT-D modes

 

for winding leader sheet

 

Mark

 

sensor

 

Leader sheet

IN2 (down count)

Rotary

IN1 (up count)

encoder

 

(single-phase)

 

IND and HOLD-D modes

for parking lots

 

 

 

FULL

 

 

VACANT

 

IN2

 

(down count)

 

IN1

 

 

(up count)

 

 

Entrance

Photoelectric

Exit

 

switch

 

Incoming and outgoing cars are counted to switch the FULL and VACANT signs.

UP and SHOT-B modes

for packing medicine tablets

Marking

Film

Cutter

Mark

sensor

Medicine tablets are packed in specified

quantities.

DIR input mode

for controlling part stocks

IN1

(counting)

IN2

(up/down count selection)

PHASE and HOLD-A modes for valve control

Rotary

encoder

To valve

Rotary encoder signals are counted to control a valve aperture.

UP and SHOT-C modes for counting acceptables

IN1

(up count)

Labeling

machine

Sorting machine

Acceptables

Mark sensor

Rejectables

IN2 (down count)

Labeled cans alone are counted up. Rejected cans are not counted.

PHASE input mode for sizing

Electric counter

Cutter

Rotary

encoder

Pipe

Extra leader sheet that is now wound is

Incoming and outgoing parts are counted

Teamed up with a rotary encoder, the

counted by a rotary encoder and a color

to keep parts feeders well-stocked.

counter is used to control the cutting

detecting sensor.

 

length of pipes.

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Image 20
Contents Timers/Time Switches/Counters/Hour Meters Product types FeaturesProduct chart PC board mounting type Installation frame type Standard typeSpecifications 100 Applicable standardCommon Dimensions Part namesInstallation frame type Panel mounting diagramPanel cut-out dimensions Terminal layout and wiring diagrams 1 Standard typePC board mounting type External dimensions Terminal layout and wiring diagramsInput method Standard type104 Explanation of operationBacklight type Voltage input type Free voltage input typeVoltage input type Backlight luminance Environment for useRoHS Directive compatibility information 106One shot/over count One shot/recount Options Mounting frame ATH3803107 Front reset key Mode keySetting key Lock switchHow to set Preset value setting modeLock mode Backlight setting modeOutput setting mode This sets the operation mode Compliance with the CE markingOperation mode 111Input and output connection Input connection Contact inputAs PNP output Self-diagnosis functionLC2H total counter one-touch installation type LC2H total counter installation frame typeLC2H preset counter Insulation sheetAccessories for LC2H total counter Lithium battery 3Installation parts Mounting frame OptionsAEL3 LCDTypical Counter Applications COUNTER-RELATED Terminology Protective circuit for counter contact Connection of input Except for LC4H-S/AC typeInstalling the counter Superimposed surge of power supplySignal input Leakage currentSockets Unit mm inch, Tolerance ±1 ±.039 143Panel cover Black AccessoriesMounting parts Surface mount Installing DIN Size CounterInstallation methods Attachment 180PM48W PM4H-W PM48W PM4HW PMH-M PM4H-M/PM4SPMH-M PM4HM-/PM4S CDX S1DXM-/S1DXLC4H LC4H MC6 LC4H-LLC48W LC4H-W LC4H EM48S LC4H-LForeign Specifications Overview Voltage Current Power During Input 120 200 720 240 Pilot Duty B300 AC applied120 600 360 240 Pilot Duty C300 AC applied 120 800 180 240Foreign Specifications Counters Hour MetersLC4H-L Pilot Duty C300 LC4H-S LC4H-W Pilot Duty C300CE Markings Overview Counter, Hour Meter conforming to EN/IEC standardsCE markings and EC directives Appropriate