Panasonic LC2H specifications Applicable standard, Common, 100

Page 4

LC2H

2. PC board mounting type

Item

Type

 

PC board mounting type

 

 

 

 

 

 

Input method

 

Non DC voltage input

No. digits

 

 

8 digits

Rated operation voltage

 

3 V DC

Allowable operation voltage range

 

2.7 to 3.3 V DC

Current consumption

 

Max. 30 µA (max. 250 µA during reset input)

Max. counting speed

2 kHz

 

30 Hz

 

 

Min. input signal width

0.25 ms

 

16.7 ms

 

 

(ON: OFF = 1:1)

 

 

 

 

 

 

Count

 

Input method

Non-voltage input using contacts or open collector connection

input

 

Input impedance

 

When shorted: Max. 10 k

 

 

 

When open: Max. 750 k

 

 

 

 

 

 

Residual voltage

 

Max. 0.5 V

 

 

Min. input signal width

 

10 ms

Reset

 

Input method

Non-voltage input using contacts or open collector connection

 

 

 

When shorted: Max. 10 k

input

 

Input impedance

 

 

 

When open: Max. 750 k

 

 

 

 

 

 

Residual power

 

Max. 0.5 V

Break down voltage (initial)

Between charged and uncharged parts: 1,000 V AC for 1 minute.

Insulation resistance (initial)

Min. 100 M(measured at 500 V DC) Measurement location same as for break down voltage.

 

 

 

 

 

 

3. Common

 

Type

Panel mounting/PC board mounting types

Item

 

Vibration resistance

Functional

10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm .006 inch (10 min. on 3 axes)

Destructive

10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm .015 inch (1 hr. on 3 axes)

 

Shock resistance

Functional

Min. 98 m/s2 (4 times on 3 axes)

Destructive

Min. 294 m/s2 (5 times on 3 axes)

 

Operation temperature

–10 to +55°C +14 to +131°F (without frost or dew)

Storage temperature

–25 to +65°C –13 to +149°F (without frost or dew)

Ambient humidity

35 to 85% RH (non-condensing)

 

 

 

Applicable standard

Safety standard

EN61010-1

 

Pollution Degree 2/Overvoltage Category III

 

(EMI)EN61000-6-4

 

 

 

Radiation interference electric field strength

EN55011 Group1 ClassA

 

Noise terminal voltage

EN55011 Group1 ClassA

 

(EMS)EN61000-6-2

 

 

 

Static discharge immunity

EN61000-4-2

4 kV contact

EMC

 

 

8 kV air

RF electromagnetic field immunity

EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz)

 

 

 

 

10 V/m pulse modulation (895 MHz to 905 MHz)

 

EFT/B immunity

EN61000-4-4

2 kV (power supply line)

 

Conductivity noise immunity

EN61000-4-6

10 V/m AM modulation (0.15 MHz to 80 MHz)

 

Power frequency magnetic field immunity

EN61000-4-8

30 A/m (50 Hz)

 

 

 

 

100

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Image 4
Contents Timers/Time Switches/Counters/Hour Meters Product chart FeaturesProduct types Specifications Installation frame type Standard typePC board mounting type Common Applicable standard100 Dimensions Part namesInstallation frame type Panel mounting diagramPanel cut-out dimensions Terminal layout and wiring diagrams 1 Standard typePC board mounting type External dimensions Terminal layout and wiring diagramsInput method Standard typeBacklight type Explanation of operation104 Voltage input type Free voltage input typeVoltage input type Backlight luminance Environment for useRoHS Directive compatibility information 106One shot/over count One shot/recount Options Mounting frame ATH3803107 Front reset key Mode keySetting key Lock switchHow to set Preset value setting modeLock mode Backlight setting modeOutput setting mode This sets the operation mode Compliance with the CE markingOperation mode 111Input and output connection Input connection Contact inputAs PNP output Self-diagnosis functionLC2H total counter one-touch installation type LC2H total counter installation frame typeLC2H preset counter Insulation sheetAccessories for LC2H total counter Lithium battery 3Installation parts Mounting frame OptionsAEL3 LCDTypical Counter Applications COUNTER-RELATED Terminology Protective circuit for counter contact Connection of input Except for LC4H-S/AC typeInstalling the counter Superimposed surge of power supplySignal input Leakage currentSockets Unit mm inch, Tolerance ±1 ±.039 143Mounting parts AccessoriesPanel cover Black Installation methods Installing DIN Size CounterSurface mount Attachment 180PM48W PM4H-W PM48W PM4HW PMH-M PM4H-M/PM4SPMH-M PM4HM-/PM4S CDX S1DXM-/S1DXLC4H LC4H MC6 LC4H-LLC48W LC4H-W LC4H EM48S LC4H-LForeign Specifications Overview Voltage Current Power During Input 120 200 720 240 Pilot Duty B300 AC applied120 600 360 240 Pilot Duty C300 AC applied 120 800 180 240Foreign Specifications Counters Hour MetersLC4H-L Pilot Duty C300 LC4H-S LC4H-W Pilot Duty C300CE Markings Overview Counter, Hour Meter conforming to EN/IEC standardsCE markings and EC directives Appropriate