LC2H
Specifications
| Item | Descriptions | |
| Rated operating voltage | 24 V DC | |
| Rated power consumption | Max. 1.5 W | |
| Rated control capacity | 100 mA 30 V DC | |
| Input mode | Addition/Subtraction (selectable by front switch) | |
| Max. counting speed | 30 Hz/5 kHz (selectable by slide switch on side) | |
| Counting input | Min. input signal width: 16.7 ms at 30 Hz/0.1 ms at 5 kHz, | |
| ON time : OFF time = 1 : 1 | ||
|
| ||
| Reset input | Min. input signal width: Min. 30 ms | |
Rating |
| • | |
Input signal | • Input impedance; when shorted: Max. 1 kΩ, when open: Min. 100 kΩ | ||
| |||
|
| • Residual voltage: Max. 2 V | |
|
| • Maintain output/hold count • Maintain output/over count | |
| Output mode | • One shot/over count • One shot/recount | |
|
| (Selectable by front switch) | |
| Display method | ||
| (Switch between red and green for backlight, and between lit and flashing for count up.) | ||
|
| ||
| Digit | ||
| (0 to 99999999 for preset value) | ||
|
| ||
| Memory | ||
Contact arrangement | 1 Form A (Open collector) | ||
Electrical life (contact) | 107 operations (at rated control voltage) | ||
| Allowable operating voltage range | 85 to 110% of rated operating voltage | |
Electrical | Break down voltage (Initial value) | Between input and output: 1,500 V AC, for 1 min. | |
| Insulation resistance (Initial value) | Between input and output: 100 MΩ (at 500 V DC) | |
| Functional vibration resistance | 10 to 55 Hz (1 cycle/min), Single amplitude: 0.15 mm (10 min. on 3 axes) | |
Mechanical | Destructive vibration resistance | 10 to 55 Hz (1 cycle/min), Single amplitude: 0.375 mm (1 hr. on 3 axes) | |
Functional shock resistance | Min. 98 m/s2 (4 times on 3 axes) | ||
| |||
| Destructive shock resistance | Min. 294 m/s2 (5 times on 3 axes) | |
Operating | Operation temperature | ||
Storage temperature | |||
conditions | |||
Ambient humidity | 30 to 85% RH (at 25°C 77°F, | ||
| |||
Protective construction | IP66 (front panel with mounting bracket and rubber gasket) | ||
* The factory default preset value is set to 1000000. |
|
Applicable standard
|
|
| ||
| Radiation interference electric field strength | EN55011 Group1 ClassA | ||
| Noise terminal voltage | EN55011 Group1 ClassA | ||
|
|
| ||
| Static discharge immunity | 4 kV contact | ||
EMC |
|
| 8 kV air | |
RF electromagnetic field immunity | ||||
| ||||
|
|
| 10 V/m pulse modulation (895 MHz to 905 MHz) | |
| EFT/B immunity | 2 kV (power supply line) | ||
|
|
| 1 kV (signal line) | |
| Conductivity noise immunity | 10 V/m AM modulation (0.15 MHz to 80 MHz) | ||
| Power frequency magnetic field immunity | 30 A/m (50 Hz) | ||
|
|
|
|
107