Panasonic PT-D5500EL manual Important the Moulded Plug U.K. only

Page 3

IMPORTANT: THE MOULDED PLUG (U.K. only)

FOR YOUR SAFETY, PLEASE READ THE FOLLOWING TEXT CAREFULLY.

This appliance is supplied with a moulded three pin mains plug for your safety and convenience. A 13 amp fuse is fitted in this plug. Should the fuse need to be replaced, please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSl to BS1362.

Check for the ASTA mark or the BSl mark on the body of the fuse.

If the plug contains a removable fuse cover, you must ensure that it is refitted when the fuse is replaced. If you lose the fuse cover, the plug must not be used until a replacement cover is obtained. A replacement fuse cover can be purchased from an Authorized Service Centre.

If the fitted moulded plug is unsuitable for the socket outlet in your home, then the fuse should be removed and the plug cut off and disposed of safely. There is a danger of severe electrical shock if the cut off plug is inserted into any 13 amp socket.

If a new plug is to be fitted, please observe the wiring code as shown below. If in any doubt, please consult a qualified electrician.

WARNING: –THIS APPLIANCE MUST BE EARTHED.

IMPORTANT: –The wires in this mains lead are coloured in accordance

with the following code: – Green-and-Yellow: Earth

Blue:Neutral

Brown:Live

As the colours of the wire in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows.

The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked with the letter E or by the Earth symbol or coloured GREEN or

GREEN-AND-YELLOW.

The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter N or coloured BLACK.

The wire which is coloured BROWN must be connected to the terminal in the plug which is

marked with the letter L or coloured RED.

FUSE

How to replace the fuse. Open the fuse compartment with a screwdriver and replace the fuse.

ENGLISH

3

Image 3
Contents Commercial Use PT-D5500ELModel number PT-D5500E/PT-D5500EL Dear Panasonic CustomerImportant the Moulded Plug U.K. only For Your SAFETY, Please Read the Following Text CarefullyContents Precautions with regard to safety Always disconnect all cables before moving the projector Insulate the battery using tape or similar before disposalDo not place liquid containers on top of the projector Do not insert any foreign objects into the projectorDo not use the old lamp unit AccessoriesUse only the Specified battery Do not look into the lens while the projector is being usedPrecautions on handling Name and function of parts Set to Computer When the operation mode selectorStatus LED lights Front and side of the projectorRear view of the main unit Controls on rear panel Side-mounted connection terminals Using the remote control unit Effective range of remote control operationLoading dry cells Setting projector ID number to remote control Using the remote control as a PC mouseOperation mode selector switch Using a wired remote control Projection distances InstallationInstallation geometry Projection schemesConnection Setup precautionsDigital Hi-vision video deck Example of connecting with AV productsDVD player Video deck Control PCExample of connecting with PCs PC withControl PC DVI port DVI-D Cable Option ET-SCDV03 How to remove the projection lens How to install the projection lensRoughly adjust the focus of the lens. Refer to Powering up the projectorMaking adjustment and selection Press the l button. on the main unit or the remote controlDirect power off function Powering off the projectorHow to adjust the lens How to adjust the lens position to the left or rightChoose an item and adjust it using buttons Press the Shutter button again Automatic adjustment Auto SetupUsing the Freeze function Using the Shutter functionUsing the digital zoom D.ZOOM + function Press the D.ZOOM + button of the remote controlChange the magnification with the D.ZOOM + button Languageenglish On-screen menusStructure of menu screens NetworkReturning to the previous Menu items settingResetting to the factory default Basic menu operationsAdjusting the picture TV-SYSTEM SharpnessAdjusting the position Raster Position How to use Advanced MenuInput Resolution Sxga ModeOption 1 settings DESK/CEILING Option 2 settingsLamp Power FRONT/REARFAN CONTROL2 PasswordSystem Information FAN CONTROL1Cycle of displayed internal test patterns Setting the passwordChanging the password Setting the textLAN cable Setting the network Connecting a PCSystem requirements Connection exampleExamples of connection Using the serial terminalsPin assignments and signal names Communication conditions Factory settingRemarks Control commandsCable specifications Connecting to a PC Computer Projector DTE specificationsUsing the Remote 2 terminal Pin assignments and controlSub 9-pin female external appearance Lamp monitor Indication of lamp monitorMonitor ReplaceDismantle the air filter Cleaning and replacement of air filterProcedure of cleaning Clean the air filterReplacing the lamp unit Timing of lamp unit replacementLamp unit replacement steps Remove the two screws securing the fan unitHave a Phillips screwdriver ready ahead of time Select the lamp which has been replaced with the and buttons Click OK Using Web Browser ControlAccess procedure Basic controlStatus information Detail controlError information When Failed has appeared for an itemParameter Description Mail setup DNS server setup Network configAdjust clock POP server setupNetwork status Password changeNot turn on Symptoms ChecksPower does Remote controlPT-D5500E PT-D5500EL SpecificationsWireless mouse receiver Length of power supply cord CabinetOutside dimensions Remote control Power sourceCompatible Signal List Calculation formulas for projection distance by lens types Projection distances by projection lensDimensions Trademark Acknowledgement Trademark acknowledgmentsM0804-1094