When the TEMP indicator and the LAMP indicator are illuminated
There are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.
LAMP indicator
TEMP indicator
TEMP indicator
Indicator | Illuminated (red) | Flashing (red) | |
display | (Lamp unit on) | (Lamp unit off) | |
|
|
| |
| The surrounding temperature or | The surrounding temperature or | |
| the temperature inside the | the temperature inside the | |
Problem | projector has become unusually | projector has become | |
high. | dangerously high, causing the | ||
|
| lamp unit to automatically shut | |
|
| off. | |
|
|
| |
Possible | BThe ventilation holes may be covered. | ||
cause | BThe ambient temperature in the place of use may be too high. | ||
| BThe air filter may be blocked. |
| |
|
|
| |
| BUncover the ventilation holes. |
| |
| BSet up the projector in a place where the temperature is | ||
| between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is | ||
| between 20% and 80% (with no condensation). [If you set the | ||
Remedy | “FAN CONTROL” to “HIGH” (page 47), set up the projector in a | ||
place where the temperature is between 0 °C (32 °F) and 35 °C | |||
| |||
| (95 °F) and the humidity is between 20% and 80% (with no | ||
| condensation).] |
| |
| BTurn off the MAIN POWER switch by following the procedure | ||
| on page 26, and then clean the air filter (refer to page 50). | ||
|
|
|
| LAMP indicator |
| ||
|
|
|
| |
Indicator | Illuminated (red) | Flashing (red) | ||
display | ||||
|
|
| ||
|
|
|
| |
| It is nearly time to | An abnormality has been detected in the lamp | ||
Problem | replace the lamp | circuit. |
| |
| unit. |
|
| |
|
|
|
| |
| BDoes “REPLACE | BThe power may | BThere may be an | |
Possible | LAMP” appear on | have been turned | abnormality in the | |
the screen after | on straight away | lamp circuit. | ||
cause | ||||
the projector is | after it was turned |
| ||
|
| |||
| turned on? | off. |
| |
|
|
|
| |
| BThis occurs when | BWait for a while | BTurn off the MAIN | |
| the operation time | until the lamp unit | POWER switch by | |
| for the lamp unit is | cools down before | following the | |
| nearing 2 700 | turning the power | procedure given | |
| hours (when | back on again. | on page 26, and | |
| “LAMP POWER” |
| then contact an | |
| has been set to |
| Authorised | |
Remedy | “HIGH” and when |
| Service Centre. | |
“DYNAMIC IRIS” |
|
| ||
|
|
| ||
| has been set to |
|
| |
| “ON”). Ask your |
|
| |
| dealer or an |
|
| |
| Authorised |
|
| |
| Service Centre to |
|
| |
| replace the lamp |
|
| |
| unit. |
|
|
NOTE:
BBe sure to turn off the MAIN POWER switch by following the procedure given in “Turning off the power” on page 26 before carrying out any of the procedures in the “Remedy” column.
BIf the power turns off after the TEMP indicator has illuminated, it means an abnormality has occurred. Please contact an Authorised Service Centre so that the necessary repairs can be made.
Care and maintenance