Panasonic TQBJ0299-3 Signal List and SUB Memory List, Managing the list and the registered data

Page 33

SIGNAL LIST

Remote control

See “Navigating through the menu” on page 15.

See “Main menu and Sub-menu” on page 12.

SIGNAL LIST and SUB MEMORY LIST

You can register a input signal as a SIGNAL LIST data, and several sets of adjusted settings for the signal as SUB MEMORY LIST data.

NOTE:

You can register data up to 96 in total number of the signal data and any corresponding sub memory data.

The names of the registered data are automatically determined by the input signals and memory numbers.

If a menu is being displayed, the new signals will be registered at the instant they are input.

Managing the list and the registered data

Registering a signal to the list

When a new format input signal is applied to the projector, press the MENU button to register to the

SIGNAL LIST.

NOTE:

The memories are numbered over 12 pages (A to L: 8 data items can be registered on each page), and the data is registered in the unused memory with the lowest number. If all the memories are used, the data of the old signals is overwritten in sequence.

When a new input signal is applied while the menu is displayed, the signal will be registered to the list.

Displaying the signal list and the status

1.Select SIGNAL LIST in the main menu.

2.Press the ENTER button.

Display the REGISTERED SIGNAL LIST.

3.Select the required signal data.

4.Press the ENTER button.

Displays the REGISTERED SIGNAL STATUS.

NAME

Input signal name

MEMORY NO.

Location address of registered data

INPUT

Connected input terminal

fH

Horizontal frequency

fV

Vertical frequency

SYNC.STATE

Polarity synchronisation

 

 

Renaming a registered data

You can rename the automatically determined registered signal data.

1.Display the REGISTERED SIGNAL LIST and select the required signal data.

2.Press the ENTER button.

Displays the REGISTERED SIGNAL STATUS of the signal.

3.Press the ENTER button.

Displays the character list.

4.Select the required character by pressing F G I H and press the ENTER button.

Repeat until complete the name.

You can enter the characters up to 16.

5.Select OK and press the ENTER button.

Displays the REGISTERED SIGNAL STATUS with NAME renamed.

Select CANCEL and press the ENTER button to return to the REGISTERED SIGNAL STATUS without any change.

Deleting a registered data

You can delete a registered data from the REGISTERED

SIGNAL LIST.

1.Display the REGISTERED SIGNAL LIST and select the required signal data.

2.Press the DEFAULT button.

Displays the REGISTERED SIGNAL STATUS of the signal for confirmation to delete.

Settings

3. Press the ENTER button.

Displays REGISTERED SIGNAL LIST and confirm the data is deleted.

Press the MENU button to cancel and return to the REGISTERED SIGNAL LIST without any change.

ENGLISH - 33

Image 33
Contents PT-DZ6700 PT-DW6300 PT-D6000 PT-D5000 Contents Screen size and throw distance Setting upProjection distance Height of the projection areaPT-DZ6710/PT-DZ6700 Setting up Projection distance by projection lensPT-DW6300 Setting upThrough ratio Fixed PT-D6000/PT-D5000PT-DZ6710/PT-DZ6700 PT-DW6300PT-D6000/PT-D5000 Screen Geometric adjustmentScreen Side viewFront leg adjusters and throwing angle Pin assignments and signal names ConnectionsBefore connection to the projector Connecting example AV equipment Connecting example ComputersConnecting with Video IN/S-VIDEO ConnectionsMain menu and Sub-menu Menu NavigationMenu Navigation Signal List Projector SetupDisplay Option Test PatternSecurity Operating procedure Adjusting with the bar scale itemsNavigating through the menu Displaying the main menuPicture menu Noise Reduction White GainSystem Daylight View SharpnessShift Position menuAspect Aspect ratio optionsClock Phase ZoomGeometry Vertical Keystone Lens Throw Ratio Position menuKeystone Setting range Input ResolutionDigital Cinema Reality BlankingAdjusting Edge Blending Adjusting with colour markersEdge Blending Selecting gamma levelBright adjustment right Marker Adjusting brightness around borderline of the image areaRaster Position Projection rangeDisplay Option menu DVI-D Auto SetupSDI ON-SCREEN DisplayStartup Logo Back ColorFreeze Side by SideInstallation Projector Setup menuHigh Altitude Mode Projector IDStandby Mode Lamp PowerREMOTE2 Mode Lamp SelectNo Signal SHUT-OFF Filter Counter ResetStatus Function ButtonDate and Time Service PasswordSave ALL Users Data InitializeTest Pattern Select Test Pattern menuPress I H to select the required test pattern Managing the list and the registered data Signal List and SUB Memory ListManaging the sub memory list Signal ListSecurity Password Security Password ChangeDisplay Setting Security menuControl Device Setup Menu Lock PasswordRemote Controller Menu LockNetwork menu Network SetupNetwork Control Network StatusTechnical Information Network connectionLAN terminal Change password Accessing with the web browserAdministrator mode Technical InformationBasic control User modeDetail control User accountNetwork config Detailed set upAdjust clock Authentication set upMail report sample Error report sample Mail set upStatus Error informationProjector status Click DetailControl commands PJLink security authorizationPJLinkTMprotocol Communication settings Pin assignments and signal namesSerial terminal ConnectionTechnical Information Basic format Cable specificationsPin assignments and control Remote 2 in terminalOther ContactRestoring the Menu Lock Password to default Side by Side function signal combination tableSide by Side function signal combination table Movie signalsTrademark acknowledgements Index Combination table Index