Technical Information
REMOTE 2 IN terminal
Using the REMOTE 2 IN terminal provided on the connection terminals of the main unit, it is possible to operate the projector from a control panel etc. furnished in a distant location where infrared remote control signal cannot be received.
Remote External
control control
Remote control/External control
Standby  ON
 ON
LAMP
| Projector set up in a meeting room | Control panel located in a different room | 
Pin assignments and control
| Pin No. | Signal name | Open (H) | Short (L) | 
| 1 | GND | 
 | GND | 
| 2 | POWER | OFF | ON | 
| 3 | RGB1 | Other | RGB1 | 
| 4 | RGB2 | Other | RGB2 | 
| 5 | VIDEO | Other | VIDEO | 
| 6 | Other | ||
| 7 | Other | ||
| 8 | SHUTTER | OFF | ON | 
| 9 | RST / SET | Controlled by remote | Controlled by external | 
| 
 | control | contact | |
| 
 | 
 | 
NOTE:
•The following buttons on the remote control and the operation area of the projector can no longer be operated when pins 1 and 9 are shortened: POWER button and SHUTTER button. Neither will it be possible to use the 
•If you short pin 1 and pin 9, and also short one of the pins from 3 to 7 and pin 1, then the following buttons on the projector operating area and the remote control can no longer be operated: POWER, RGB1, RGB2, 
Appendix
ENGLISH - 47