Zebra Technologies GC420t manual 65536k.......B only displays this if installed

Page 103

ZPL Configuration Status to Command Cross-reference

The configuration settings listed here resume after the TAKE LABEL sensor value. These listings contain printer features seldom changed from default or provide status information (e.g. Firmware Version).

91

Table 3 • ZPL Commands and Configuration Receipt Callout Cross-Reference

Command

Listing Name

Description

 

 

 

^MP

MODES ENABLED

Default: CWF (See ^MP Command)

 

 

(CWFM for wireless printers with display)

 

 

 

 

MODES DISABLED

Default: (nothing set)

 

 

 

^JM

RESOLUTION

Default: 832 8/mm FULL (203 dpi)

 

 

1280 8/mm FULL (300 dpi)

 

 

 

FIRMWARE

Lists ZPL Firmware Version

 

 

 

XML SCHEMA

1.3

 

 

 

HARDWARE ID

Lists Firmware Boot-block Version

 

 

 

CONFIGURATION

CUSTOMIZED (after first use)

 

 

 

RAM

2104k........ R:

 

 

 

OPTION MEMORY

65536k.......B: (only displays this if installed)

 

 

 

ONBOARD FLASH

1536k.........E:

 

 

 

^MU

FORMAT CONVERT

NONE

 

 

 

^JI / ~JI

ZBI

DISABLED (Requires key to enable)

 

 

 

ZBI VERSION

2.1

 

 

 

^JH

LAST CLEANED

X,XXX IN

^MA

 

 

HEAD USAGE

X,XXX IN

~RO

 

 

TOTAL USAGE

X,XXX IN

 

 

 

 

 

RESET CNTR1

X,XXX IN

 

 

 

 

RESET CNTR1

X,XXX IN

 

 

 

SERIAL NUMBER

XXXXXXXXXXX

 

 

 

^JH

EARLY WARNING

MAINT. OFF

 

 

 

The printer has the ability to set a command or a group of commands once for all receipts (or labels) that follow. Those settings will remain in effect until they are changed by subsequent commands, the printer is reset, or you restore factory defaults.

5/22/2012

GC420t™ User Guide

P1052686-001

Image 103
Contents Zebra GC420t P1052686-001 GC420t User Guide 22/2012 Iii FCC Compliance Statement About This Document ContentsHow This Document Is Organized Who Should Use This DocumentMail Back Technical Library ContactsIcons Used Document ConventionsContents Print Operations Appendix Dimensions P1052686-001 GC420t User Guide 22/2012 Introduction GC420t Thermal Printers Unpack and Inspect the Printer What’s in the Box?Opening the printer Your PrinterPrinter Features Operator Controls Power Switch Status Light Feed ButtonClosing the printer Getting Started ContentsAttaching Power Preparing Media Loading Roll MediaPlacing the Roll in the Media Compartment Loading Roll Media Guides Loading Transfer Ribbon Loading Transfer Ribbon Loading Transfer Ribbon Loading Transfer Ribbon Printing a Test Printer Configuration Label Pre-install Windows Printer Drivers Serial Port and Windows operating systems Universal Serial Bus USB Device CommunicationsInterface Cable Requirements Connecting your Printer to a ComputerUSB Interface Requirements Autobaud Serial CommunicationsEPL Y Command Parallel Port After Your Printer is Connected Testing Communications by PrintingAfter Your Printer is Connected Print Operations Long Term Printer In-activity or Storage Determining Printer ConfigurationThermal Printing Print Media Types Modes of PrintingTypes of Media Roll and Fanfold Media Determining Thermal Media Types Replacing SuppliesAdding a New Transfer Ribbon Adjusting the Print Quality Adjusting the Print WidthReplacing a Partially Used Transfer Ribbon Media Sensing Ribbon Overview When to Use RibbonCoated Side of Ribbon Ribbon Scratch Test Ribbon Test with AdhesivePrinting on Fan-Fold Media Printing on Fan-Fold Media Externally Mounted Roll Media Considerations Printing with Externally Mounted Roll MediaLocalizing the Printer with Code Pages Fonts and Your PrinterZPL Fonts Identifying Fonts in Your PrinterStand Alone Printing Sending Files to the Printer Print Meter Printer Options XA MMP XZ Label Dispenser OptionLabel Dispenser Option Label Dispenser Option Zebra KDU Printer Accessory KDU Plus Printer Accessory ZBI 2.0 Zebra Basic Interpreter ZBI 2.0 Zebra Basic Interpreter Maintenance See Cleaning the Printhead on CleaningCleaning the Printhead Media Path Considerations Sensor Cleaning Platen Cleaning and Replacement Maintenance Other Printer Maintenance Replacing the Printhead Maintenance Unplug both bundles of printhead wires from their connectors Maintenance Troubleshooting Status Light Descriptions Status Light Error Resolutions Printhead is open Printhead is over temperatureMedia is out Ribbon is outNo print on the label Print Quality ProblemsPrinted image does not look right Print Quality Problems Is the printer in pause mode? If so, press the Feed button Manual Calibration Printing a Configuration Label Troubleshooting TestsRecalibration Communications Diagnostics Resetting the Factory Default ValuesCommunications Diagnostics Flash Sequence Action Feed Button ModesPower On Modes Feed Button Modes Appendix Interface Wiring Universal Serial Bus USB Interface Host Parallel InterfaceSerial Port Interface Connecting the Printer to a DCE DeviceAppendix Dimensions External GC420t Printer Dimensions Optional Label Dispenser External GC420t Printer Dimensions Appendix ZPL Configuration ZPL Printer Configuration Format Managing the ZPL Printer ConfigurationConfiguration Label Printout ZPL Configuration Status to Command Cross-referenceDefault 65536k.......B only displays this if installed ZPL Programming for Memory Management Printer Memory Management and Related Status Reports~WC Printer Memory Management and Related Status Reports