Zebra Technologies 2844 user manual Female DB-25 to Male Centronics Cable

Page 33

Appendix A - Troubleshooting

Parallel Interface The figure below displays the cable wiring Cable Wiring required to use the printer's Centronics parallel

interface.

HOST

DB-25

Centronics

PRINTER

Pin No.

Pin No.

STROBE

1

1

STROBE

DATA 0

2

2

DATA 0

DATA 1

3

3

DATA 1

DATA 2

4

4

DATA 2

DATA 3

5

5

DATA 3

DATA 4

6

6

DATA 4

DATA 5

7

7

DATA 5

DATA 6

8

8

DATA 6

DATA 7

9

9

DATA 7

ACK/

10

10

ACK/

BUSY

11

11

BUSY

PAPER ERR.

12

12

PAPER ERR.

READY

13

13

READY

INIT

14

14

INIT

ERROR/

15

15

ERROR/

N/A

16

16

N/A

N/A

17

17

N/A

N/A

18

18

+5V

SIG. GND

19

19

SIG. GND

SIG. GND

20

20

SIG. GND

SIG. GND

21

21

SIG. GND

SIG. GND

22

22

SIG. GND

SIG. GND

23

23

SIG. GND

SIG. GND

24

24

SIG. GND

SIG. GND

25

25

 

 

 

 

Female DB-25 to Male Centronics

(Cable)

+5 volts at 300 mA for external device (e.g. KDU or scanner)

980348-001 Rev. A

27

Image 33
Contents Thermal Printer User’s Manual 2844 980348-001 Rev. a LP 2844 and TLP 2844 Thermal Printers ForewordShock Hazard Warning Table of Contents 980348-001 Rev. a Installation and Operation Unpack Your Printer Know Your Printer Installation and Operation Step ➊ Attach Power Supply To The Printer Serial Parallel Step ➋ Attach Interface CablePower on Step ➌ Load MediaOpen Cover Open Guides Load Media Install RollClose Cover Release CoverStep ➍ AutoSense Media Gap Sensing Power OFFAutoSense Gap Sensor Adjustment Step ➎ Install Software Direct or Transfer? Using Options Step ➊ Prepare Ribbon Thread Ribbon Through Carriage Step ➋ Install Supply RollStep ➌ Install Take-Up Core Attach Ribbon to Take-Up Core Remove Slack From Ribbon Step ➍ Tighten RibbonPush Supply Roll Out Partially UsedOpen Door Using the Label DispenserInsert Media Using Fan-Fold MediaUsing the Media Cutter 980348-001 Rev. a Problem Solution or Reason Appendix a TroubleshootingRED Troubleshooting Media Handling Host Female DB-25 to Male Centronics Cable Bus USB For the cable connectorsRub CleaningPen Across Dark AreaCleaning the Platen Before Loading Preparing MediaLabel Rolls Tag Stock Rolls980348- 001 a