B&B Electronics RT12-0044-ZP-12, RT12-4444-9T-W20 manual Wireless Modbus I/O Modules

Page 1

Zlinx series

Wireless Modbus I/O Modules

Models:

RT12-0044-ZP-12

RT12-2222-ZP-12

RT12-4444-9T-W20

Documentation Number: RT-12 series-4006m (pn#7331)

This product designed and manufactured in Ottawa, Illinois USA

of domestic and imported parts by

707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA

Phone (815) 433-5100 -- General Fax (815) 433-5105

Phone (815) 433-5100 -- General Fax (815) 433-5105

Website: www.bb-elec.com

Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109

Technical Support e-mail: support@bb.elec.com -- Fax (815) 433-5104

European Headquarters

B&B Electronics

Westlink Commercial Park -- Oranmore, Co. Galway, Ireland

Phone +353 91-792444 -- Fax +353 91-792445

Website: www.bb-europe.com

Sales e-mail:sales@bb-europe.com

Technical Support e-mail:support@bb-europe.com

B&B Electronics Mfg. Co. Inc. -- October 2006

Manual Documentation Number: RT-12 series-4006m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.comB&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

DO NOT OPERATE ANY EQUIPMENT UNTIL THIS MANUAL

IS READ IN ITS ENTIRETY

2006 B&B Electronics. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of B&B Electronics.

B&B Electronics shall not be liable for incidental or consequential damages resulting from the furnishing, performance, or use of this manual.

All brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder.

This document contains information that is proprietary and confidential to B&B Electronics Mfg. Co. Inc. The methods described herein are for the exclusive use of B&B Electronics authorized personnel. Any unauthorized use or dissemination of the information contained in the document is strictly forbidden.

Manual Documentation Number: RT-12 series-4006m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.comB&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Image 1
Contents Wireless Modbus I/O Modules Wireless I/O Modules from B&B Electronics Table of Contents For Peer-to-Peer mode, check and confirm the following Theory of OperationFor Modbus Slave RTU mode, check and confirm the following Modbus Overview Modbus Register Maps Modbus Functions SupportedRT12-4444 Modbus Map Peer to Peer Overview RT12-2222 Modbus MapConnection Screw Terminal Description RT12-4444-9T-W20 Front Panel IdentificationTo Connect to a Controller Data Activity LED Indicators Power 10.5~28 VdcLink/Sanity LED Indicators Serial RS-232 InterfaceRT12-2222-ZP-S12 Front Panel Identification RT12-4444-9T-W20 External Battery Back-upConnection Screw Terminals Description RT12-0044-ZP-S12 Front Panel Identification RT12-2222-ZP-S12 External Battery Back-upPower 10.5~28 Vdc Hardware Set-up RT12-0044-ZP-S12 External Battery Back-upTypical Application Peer-to-Peer Typical Application Peer-to-Peer Typical Application Modbus Typical Application Well Monitor and Control Modbus Typical Application Well Monitor and Control Peer-to-PeerTypical Application 4-20 mA to Voltage Conversion Configuration Cable DescriptionPin# Connection color Configuration/Monitoring Software Main Configuration/Monitoring Software System MapCurrent Controller Settings Controller ConfigurationManual Documentation Number RT-12 series-4006m Master, Slave, Modbus, Peer-to-Peer Connecting / DisconnectingDigital Input Types Modbus ConfigurationRTU Alarms Analog Outputs Resting Voltage Input Voltage Alarm LimitsManual Documentation Number RT-12 series-4006m Third Party Communications Protocol Support Updating/Sending Configuration to RTUDigital Outputs Status Bar