Connecting / Disconnecting

Connect: Pressing the “Connect” button will force the software to make an attempt to connect to the controller your PC. The programming cable must be connected. The connect button will start RED and will remain RED until a connection is made.

The “Assert” check box will indicate “Checked” when the software makes the attempt to connect.

Once connected, the “Connected” check box will indicate, “Checked” and the “Connect” button will turn green.

Disconnect: Pressing the “disconnect” button will force the software to disconnect from the controller your PC is connected to. Both the “Assert” and “Connected” check boxes will indicate “Unchecked”.

NOTE: The controller must be “Disconnected” for the master and slave to communicate with each other.

You may need to make several attempts to connect. Make sure the “Connected” box is check and the “Connect” button is GREEN, before proceeding.

During the “Connect” process you will notice a series a check marks, in the “Update” configuration Block, located next to each of the subsystems. This is confirmation that the configuration software is collecting data from the respective RTU.

Manual Documentation Number: RT-12 series-4006m

35

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.comB&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Master, Slave, Modbus, Peer-to-Peer

Master: If the controller you are connected to is a Master Peer to

Peer device, the Wireless type will indicate “Master”.

Slave: If the controller you are connected to is a Slave Peer to Peer device, the Wireless type will indicate “Slave”.

MODBUS: If the controller you are connected to is in MODBUS mode the Wireless type will indicate “MODBUS”.

P-2-P:P-2-P is also Peer to Peer.

If your system is configured as a Peer to Peer system, the system must consist of one Master and one Slave. The Master controller is responsible for starting the polling sequence.

If your controller is configured as a MODBUS controller then typical Modbus, Slave, RTU, protocol applies. Do not allow for duplicate Slave address within the same system, unless It is on a separate Radio Id and/or RF-Network ID.

36

Manual Documentation Number: RT-12 series-4006m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.comB&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Image 21
Contents Wireless Modbus I/O Modules Wireless I/O Modules from B&B Electronics Table of Contents Theory of Operation For Peer-to-Peer mode, check and confirm the followingFor Modbus Slave RTU mode, check and confirm the following Modbus Overview Modbus Functions Supported Modbus Register MapsRT12-4444 Modbus Map Peer to Peer Overview RT12-2222 Modbus MapRT12-4444-9T-W20 Front Panel Identification Connection Screw Terminal DescriptionTo Connect to a Controller Data Activity LED Indicators Power 10.5~28 VdcLink/Sanity LED Indicators Serial RS-232 InterfaceRT12-2222-ZP-S12 Front Panel Identification RT12-4444-9T-W20 External Battery Back-upConnection Screw Terminals Description RT12-0044-ZP-S12 Front Panel Identification RT12-2222-ZP-S12 External Battery Back-upPower 10.5~28 Vdc RT12-0044-ZP-S12 External Battery Back-up Hardware Set-upTypical Application Peer-to-Peer Typical Application Peer-to-Peer Typical Application Modbus Typical Application Well Monitor and Control Modbus Typical Application Well Monitor and Control Peer-to-PeerConfiguration Cable Description Typical Application 4-20 mA to Voltage ConversionPin# Connection color Configuration/Monitoring Software Main Configuration/Monitoring Software System MapCurrent Controller Settings Controller ConfigurationManual Documentation Number RT-12 series-4006m Master, Slave, Modbus, Peer-to-Peer Connecting / DisconnectingDigital Input Types Modbus ConfigurationRTU Alarms Analog Outputs Resting Voltage Input Voltage Alarm LimitsManual Documentation Number RT-12 series-4006m Third Party Communications Protocol Support Updating/Sending Configuration to RTUDigital Outputs Status Bar