Panamax MAX 5410 SignalPerfect Coaxial Line Protection, SignalPerfect Telephone Line Protection

Page 11

FEATURE DETAILS

UTLETS

 

 

 

SATELLITE

 

CATV/ANT

 

 

 

USB

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

RS232 CONTROL

LIGHT

 

 

 

 

 

 

12V TRIGGER

 

 

HC

 

LINE

EQUIP. 1

EQUIP. 2

IN

OUT

TRIGGER

TRIGGER

SWITCHED

 

 

OUTLETS

OUTLETS

 

 

 

 

 

ENABLE

DELAY

DELAY

DELAY

 

 

 

UTLETS

 

 

 

SATELLITE

 

CATV/ANT

 

 

 

USB

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

RS232 CONTROL

LIGHT

 

 

 

 

 

 

12V TRIGGER

 

 

HC

 

LINE

EQUIP. 1

EQUIP. 2

IN

OUT

TRIGGER

TRIGGER

SWITCHED

 

 

OUTLETS

OUTLETS

 

 

 

 

 

ENABLE

DELAY

DELAY

DELAY

 

 

 

UTLETS

 

 

 

SATELLITE

 

CATV/ANT

 

 

 

USB

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

RS232 CONTROL

LIGHT

 

 

 

 

 

 

12V TRIGGER

 

 

HC

 

LINE

EQUIP. 1

EQUIP. 2

IN

OUT

TRIGGER

TRIGGER

SWITCHED

 

 

OUTLETS

OUTLETS

 

 

 

 

 

ENABLE

DELAY

DELAY

DELAY

 

 

 

SignalPerfectCoaxial Line Protection

All coaxial cable sheaths from outdoors must be grounded to the building grounding electrode system where they enter the building (per applicable NEC/CEC code). A driven ground rod is not adequate.

Panamax’s exclusive SignalPerfect™ Technology provides application-specific protection for your satellite and cable TV equipment. Two lines of protection are provided for each type. The satellite connections are for coaxial cables connected to a DBS (single or dual LNB) satellite dish. The antenna connection is for a non-amplified rooftop antenna or cable TV line. The Additional TV connection protects the equipment plugged into the MAX® 5410 from “backdoor” surges in situations where the video signal runs to another room for a downline TV.

Cable TV (Including HDTV) – TV tuners operate at approximately 10 millivolts (0.01 V) and utilize the frequency spec- trum of 50Mhz to 950Mhz. The clamping level of the MAX® 5410’s cable TV protection circuitry is 700 millivolts (0.7 volts). That’s less than 1 volt above normal operating levels. The circuitry is shielded to prevent interference and has been opti- mized to have less than 1dB of signal loss throughout the entire 50Mhz to 950Mhz range.

Satellite - Satellite dish LNB’s can require up to 24 volts to operate and utilize the frequency range of 950Mhz to 2.2Ghz. The clamping level of the MAX® 5410’s satellite protection circuitry is 27 volts - just 3 volts above the maximum operating voltage. The circuitry is shielded to prevent interference and has been optimized to have less than 1dB of signal loss throughout the entire 950Mhz to 2.2Ghz range.

UTLETS

 

 

 

SATELLITE

 

CATV/ANT

 

 

 

USB

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

RS232 CONTROL

LIGHT

 

 

 

 

 

 

12V TRIGGER

 

 

HC

 

LINE

EQUIP. 1

EQUIP. 2

IN

OUT

TRIGGER

TRIGGER

SWITCHED

 

 

OUTLETS

OUTLETS

 

 

 

 

 

ENABLE

DELAY

DELAY

DELAY

 

 

 

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

ALW

15A BREAKER

 

 

GROUND

 

 

IEC320 INLET

 

 

SignalPerfectTelephone Line Protection

Satellite TV receivers require a telephone line connection for Pay-Per-View services. The MAX® 5410 also provides surge protection for this line. The circuitry utilizes auto-resetting PTCRs and solid-state SIDACtors™ for reliability and unsur- passed protection. The clamping level of the MAX® 5410’s telephone protector is 260 volts. This will allow typical ring voltage (90-130VAC) and operating battery voltage (-48DC) to pass through the circuit and still protect the modem in your satellite receiver from damage.

RJ-11 phone jacks are provided for this protection. A built-in line splitter allows 2 separate components to be connected to the same phone lines.

Please note: The protection circuitry will not work if the phone lines are reversed. The incoming phone cable must be connected to the "LINE" jack and the cable to the audio/video equipment must be connected to the "EQUIP" jack.

Power Cord

The MAX® 5410 comes equipped with a UL recognized, 10 foot, IEC320 power cord rated for 120V, 15-Amps, minimum 14 gauge wire and the cord secured to the enclosure with a cord retention bracket. The cord is not intended to be removed.

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

 

9

Image 11
Contents MAX 5410 Pro Series Model # M5410 Before YOU Begin Table of ContentsHigh-Current Outlet Bank Other Features Enhance FunctionalityIntroduction Filtered Outlet BanksBasic Signal Line Connections Connection DiagramsTypical AC Power, RS232 and 12V Trigger Connections LED Feature OverviewFront Panel Pushbutton Feature DetailsDiagnostic Lights Convenience Outlet Meter Light ControlVoltmeter High Current Outlets Filtered Outlet BanksCircuit Breaker High-Current Outlet BankVoltage Sense Trigger DC Triggers Power Cord SignalPerfect Coaxial Line ProtectionSignalPerfect Telephone Line Protection SurgeGate Plus Protection Protect or Disconnect AC Surge ProtectionEmail custrelations@panamax.com Fax Technical SpecificationsContacting Panamax What Does EMI and RFI stand for? Can the MAX 5410 be included in an Equipment rack?OFF with the MAX 5410. How can I fix This? Spike?MAX PRO-SERIES RS-232 Command Specifications