Panamax MAX 5410 owner manual Technical Specifications, Contacting Panamax

Page 13

TECHNICAL SPECIFICATIONS

GENERAL

 

 

Dimensions

17” W x 12” D x 3.5” H, (4.1” Including Feet)

Weight

15 lbs.

 

 

 

AC CIRCUIT

 

 

NOISE FILTRATION:

 

 

Filtered Outlet Banks 1 & 3

100 dB (100 KHz - 1 MHz)

Filtered Outlet Banks 2 & 4

90 dB (100 KHz - 1 MHz)

High-Current Outlets

60 dB (100 KHz - 1 MHz)

SURGE PROTECTION:

 

 

UL 1449 Surge Suppression Rating

................................................................330V

Protection Modes

L - N, L - G, N - G

Initial Clamping Level

200V Peak, 141V Rms

Response Time

<1ns

Joule Rating

2325 Joules

Peak Impulse Current

91,000A

Catastrophic Surge Circuit

YES

AC:

 

 

Line Voltage

120VAC

Max Current Rating

15A (1800 Watts)

Thermal Fuse

YES

Over/Under Voltage Protection

YES

Over-voltage shutoff threshold

134±4 VAC, 10 Milliseconds

Under-voltage shutoff threshold

95±4 VAC, 500 Milliseconds

 

 

 

Design and specifications subject to change without notice due to product improvement.

DC TRIGGER OUTPUT

Connection

3.5mm mono mini-plug

Voltage

±12VDC ±2V

Current

350mA

DC TRIGGER INPUT

Connection

3.5mm mono mini-plug

Voltage and Polarity

3-18VDC nominal, bi-directional

Current Requirement

25mA

SATELLITE CIRCUIT

Clamping Level

................................................................................................27V

Attenuation

<1 dB from 950MHz - 2.2GHz

Shielded

YES

Connections

Gold plated, Female “F”

 

 

ANT/CATV CIRCUIT

Clamping Level

...............................................................................................0.7V

Attenuation

<1 dB from 5MHz -950MHz

Shielded

YES

Connections

Gold plated, Female “F”

TELEPHONE CIRCUIT

Clamping Level

260V

Capacitance

30pf (approx.)

Suppression Modes

Metallic & Longitudinal

Wires Protected

2 wire/ 1 pr. (pins 4,5)

Fuseless/Auto-Resetting

YES

Connections

RJ-11

 

 

CONTACTING PANAMAX

For product and warranty information, dealer information, and other general information contact Customer Relations at:

Email: custrelations@panamax.com

www.panamax.com

Fax 707-283-5901

800-472-5555or 707-283-5900, 7:30 a.m.- 4:30 p.m. PST

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

 

11

Image 13
Contents MAX 5410 Pro Series Model # M5410 Before YOU Begin Table of ContentsIntroduction Other Features Enhance FunctionalityFiltered Outlet Banks High-Current Outlet BankTypical AC Power, RS232 and 12V Trigger Connections Connection DiagramsBasic Signal Line Connections LED Feature OverviewDiagnostic Lights Feature DetailsFront Panel Pushbutton Voltmeter Meter Light ControlConvenience Outlet High Current Outlets Filtered Outlet BanksVoltage Sense Trigger DC Triggers High-Current Outlet BankCircuit Breaker SignalPerfect Telephone Line Protection SignalPerfect Coaxial Line ProtectionPower Cord SurgeGate Plus Protection Protect or Disconnect AC Surge ProtectionContacting Panamax Technical SpecificationsEmail custrelations@panamax.com Fax OFF with the MAX 5410. How can I fix This? Can the MAX 5410 be included in an Equipment rack?Spike? What Does EMI and RFI stand for?MAX PRO-SERIES RS-232 Command Specifications