Panamax MAX 5410 owner manual MAX PRO-SERIES RS-232 Command Specifications

Page 15

MAX PRO-SERIES RS-232 COMMAND SPECIFICATIONS

1. OVERVIEW

The Panamax Pro-Series product family has a RS232 interface that allows it to communicate with a wide variety of equipment.

The purpose of this document is to outline the command set used to communicate with the Pro-Series (PS) products.

Commands and responses are in the form of ASCII character STRINGS TERMINATED with ASCII 13, line feed (ASCII 10) or NULL (ASCIØ).

2. CONTROLLER COMMANDS

The following are commands made by the controller to Pro-Series products.

DB9 Pinout Diagram

5

4

3

2

1

6

7

 

8

9

PIN NO.

 

SIGNAL

 

1

 

 

-

 

2

TRANSMIT

3

RECEIVE

 

4

 

 

-

 

5

SIGNAL GROUND

6

 

 

-

 

7

 

 

-

 

8

 

 

-

 

9

 

 

-

 

 

Command String

Description / Response

Command String

Description / Response

 

 

 

 

 

 

 

 

2.1

POWERON

Changes the front panel button status to

2.13

?TRIGSTAT

Request the status of the 12V trigger input. PS responds with:

 

 

 

ON. Initiates a power-on sequence if the

 

 

a) 12VINHI if voltage is sensed on the12V input

 

 

 

previous state is OFF.

 

 

b) 12VINLO if 0V is sensed on the 12V input

 

 

 

 

 

 

 

c) BUTTONON if the ON/OFF button status is ON.

2.2

POWEROFF

Changes the front panel button status to

 

 

d) BUTTONOFF if the ON/OFF button status is OFF.

 

 

 

OFF. Initiates a power-off sequence if the

 

 

e) 12VOUTHI if the trigger output is ON (+12V)

 

 

 

previous state is ON. (Default)

 

 

f) 12VOUTLO if the trigger output is OFF (0V)

 

 

 

 

 

 

 

 

2.3

CYCLESW

Initiates a power cycle sequence for the

2.14

?OUTLETSTAT

Request the status of the outlet banks. PS responds with:

 

 

 

Switched Outlets only.

 

 

a) MAINACON if all outlets (main relay) are ON

 

 

 

 

 

 

 

b) MAINACOFF if all outlets are OFF

2.4

CYCLEHC

Initiates a power cycle sequence for the

 

 

c) SWITCHEDON if the switched outlets are ON

 

 

 

High Current Outlets only.

 

 

d) SWITCHEDOFF if the switched outlets are OFF

 

 

 

 

 

 

 

e) HICURRENTON if the high-current (delayed) outlets are ON

2.5

CYCLE

Initiates a power-cycle sequence. Switched

 

 

f) HICURRENTOFF if the high-current outlets are OFF

 

 

 

& high-current outlets turn off, followed by

 

 

 

 

 

 

 

a 10 second delay, followed by a power-on

2.15

?PWRSTAT

Request the status of the input voltage

 

 

 

sequence.

 

 

a) NORMAL if the voltage is within limits

 

 

 

 

 

 

 

b) OVERVOLTAGE if the voltage is greater than 132VAC

2.6

ALLOFF

Turns off all outlets. Forces front panel

 

 

c) UNDERVOLTAGE if the voltage is less than 95VAC

 

 

 

button status to OFF.

 

 

d) RECOVERY if recovering from an over/undervoltage state but

 

 

 

 

 

 

 

has not yet restored power to outlets.

2.7DETACHTRIG Disconnects 12V trigger output from 12V

 

 

trigger input

2.18

?ID

Request that the unit identify itself. Returns the following:

 

 

 

 

 

PANAMAX: MAX 5410

2.8

ATTACHTRIG

12V trigger input passes through to 12V

 

 

FW: SFW5410

 

 

trigger output (Default)

 

 

REV: revision

 

 

 

 

 

 

2.9

TRIGOUTLO

Forces the 12V trigger output to 0V. Does

2.19

HELP

All commands and queries listed above are transmitted.

 

 

not work when trigger is attached to 12V

 

 

 

 

 

trigger input.

 

 

 

2.10TRIGOUTHI Forces the 12V trigger output to 12V. Does not work when trigger is attached to 12V trigger input.

 

 

13

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

 

Image 15
Contents MAX 5410 Pro Series Model # M5410 Before YOU Begin Table of ContentsHigh-Current Outlet Bank Other Features Enhance FunctionalityIntroduction Filtered Outlet BanksConnection Diagrams Typical AC Power, RS232 and 12V Trigger ConnectionsBasic Signal Line Connections LED Feature OverviewFeature Details Diagnostic LightsFront Panel Pushbutton Meter Light Control VoltmeterConvenience Outlet High Current Outlets Filtered Outlet BanksHigh-Current Outlet Bank Voltage Sense Trigger DC TriggersCircuit Breaker SignalPerfect Coaxial Line Protection SignalPerfect Telephone Line ProtectionPower Cord SurgeGate Plus Protection Protect or Disconnect AC Surge ProtectionTechnical Specifications Contacting PanamaxEmail custrelations@panamax.com Fax What Does EMI and RFI stand for? Can the MAX 5410 be included in an Equipment rack?OFF with the MAX 5410. How can I fix This? Spike?MAX PRO-SERIES RS-232 Command Specifications