FEATURE OVERVIEW
Switched Outlets Pushbutton: | LED Indicators: |
| Meter Light Dimmer: | Voltmeter: | |
1 of 2 Triggers that can activate a | Status indicator lights |
| Controls brightness | Backlit analog meter | |
for Switched Outlets, |
| of the Voltmeter | measures incoming | ||
Outlet Bank 2 and | DC Voltage Trigger, |
| backlighting. | voltage source from | |
| Ground OK, |
|
| ||
| Line Fault |
|
|
| |
| and Unsafe Voltage |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Convenience Outlet:
Provides a quick convenient way to plug in components such as camcorders and video game systems.
15A Circuit Breaker:
Opens in the event that equipment plugged into the MAX® 5300 draws too much current. When the white button of the breaker is visible, the breaker has opened. Reduce the load and push to reset.
Filtered Outlet Bank 1:
Four
Filtered Outlet Bank 2:
Four switched, Balanced Double L filtered outlets for audio/video components that do not require constant power.
High Current Outlet Bank: | Satellite Coax Jacks: | Cable TV Coax Jacks: | |
Two delayed outlets designed for | Two pairs of gold plated | Two pairs of gold plated | |
amplifiers and powered subwoofers. | for Satellite TV signal | Cable TV and | |
The current available to connected | line protection. | fied Rooftop Antenna signal | |
equipment is not limited by the |
| line protection. | |
noise filtration components. |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
IEC Main Power | Ground Lug: | Voltage Sense |
| Voltage Sense |
| High Current |
| Outlet Bank 2 Turn- |
| Telephone Jacks: |
Receptacle: | Provides a | Trigger Input: |
| Trigger Output: |
| Outlets |
| Off Switch: |
| In/Out connections |
Detachable power | common | 1/8 inch |
| 1/8 inch |
| Switch: |
|
| for telephone line or | |
cord connects to | grounding point | Connect to a remote trigger |
| Connecting a 12VDC trig- |
|
| Allows adjustment of the |
| ||
this receptacle. | for equipment | device that provides 12VDC to |
| ger to the Voltage Sense |
| Allows adjustment of |
|
| protection. | |
| with separate | trigger a startup/shutdown |
| Circuit will allow the same |
| the |
| Bank 2. Choose |
|
|
| ground leads. | sequence. This is the second |
| signal to pass through the |
| the two |
| between |
|
|
|
| trigger that will activate the |
| Voltage Sense Output to |
| Outlets. Choose |
| 10 and 30 seconds. |
|
|
|
| MAX® 5300 |
| control the startup/shut- |
| between 0, 10 and 30 |
|
|
|
|
|
| down sequence. (See switched |
| down of an additional |
| seconds. |
|
|
|
|
|
| outlets pushbutton on front |
| device. |
|
|
|
|
|
|
|
| panel). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | 150 Mitchell Blvd., San Rafael, CA 94903 • www.panamax.com |