American Power Conversion SUA3000XL NETPKG, 230 Vac, 208 VAC, 120 Vac Input circuit breaker trips

Page 14

Problem and/or Possible Cause

Solution

 

 

The Overload LED is illuminated and the UPS emits a sustained alarm tone

 

 

The UPS is overloaded.

The connected equipment exceeds the specified “maximum load” as defined

 

in Specifications on the APC Web site, www.apc.com.

 

The alarm remains on until the overload is removed. Disconnect nonessential

 

equipment from the UPS to eliminate the overload condition.

 

The UPS continues to supply power as long as it is online and the circuit

 

breaker does not trip; the UPS will not provide power from batteries in the

 

event of a utility voltage interruption.

 

 

The Replace Battery/Battery Disconnected LED is illuminated

 

 

The Replace Battery/Battery

Check that the battery connectors are fully engaged.

Disconnected LED flashes and a short

 

beep is emitted every two seconds to

 

indicate the battery is disconnected.

 

 

 

Weak battery

Allow the battery to recharge for 24 hours and perform a self-test. If the

 

problem persists after recharging, replace the battery.

 

 

Failure of a battery self-test: Replace

Allow the battery to recharge for 24 hours. Perform the self-test procedure to

Battery/Battery Disconnected LED

confirm the replace battery condition. The alarm stops and the LED clears if

illuminates and the UPS emits short

the battery passes the self-test.

beeps for one minute. The UPS repeats

If the battery fails again, it must be replaced. The connected equipment is

the alarm every five hours.

unaffected.

 

 

 

The Site Wiring Fault LED on the rear panel is illuminated (120 V model only)

 

 

The UPS is plugged into an improperly

Wiring faults detected include missing ground, hot-neutral polarity reversal,

wired utility power outlet.

and overloaded neutral circuit.

 

Contact a qualified electrician to correct the building wiring.

 

 

The input circuit breaker trips

 

 

 

The connected equipment exceeds the

Unplug all nonessential equipment from the UPS.

specified “maximum load” as defined

Reset the circuit breaker.

in Specifications on the APC Web site,

 

www.apc.com.

 

 

 

The AVR Boost or AVR Trim LEDs are illuminated

 

 

The system is experiencing very high or

Have a qualified service personnel check your facility for electrical

low utility voltage.

problems. If the problem persists, contact the utility company for further

 

assistance.

 

 

14

Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual

Image 14
Contents APC Smart-UPS→XL Page Introduction SpecificationsRead the Safety Guide before installing the UPS About this UPSInstallation Tower ConfigurationRack-Mount Configuration Tower to rack-mount conversion procedureAccessories Install unit in rackRear Panels Connect Equipment and Power to the UPSStart-Up Start the UPSEmergency Power Off Communication Ports120/208 Display Panel Indicators and Function ButtonsOperation 230Feature Feature Title Function Button Configuration UPS settingsBrightly Troubleshooting Problem and/or Possible Cause SolutionAVR Boost or AVR Trim LEDs are illuminated Replace Battery/Battery Disconnected LED is illuminatedInput circuit breaker trips Battery Charge and Load LEDs flash simultaneously There is no utility powerUPS operates on battery although line voltage exists Diagnostic utility voltageService Maintenance, Transport, and ServiceReplacing the Battery Module Two-Year Warranty Terms of warrantyFCC Compliance Notice 120/208 V models Regulatory InformationRegulatory Agency Approvals and Radio Frequency Warnings ModelsDate of product declaration
Related manuals
Manual 17 pages 20.71 Kb

2200 VA XL, 3000 VA XL, 208 VAC, 230 Vac, SUA3000XL specifications

American Power Conversion (APC), a division of Schneider Electric, is a leading provider of power protection and management solutions, particularly in the fields of uninterruptible power supplies (UPS), power distribution, and cooling solutions. One notable product within their extensive range is the APC 230 VAC, 750,100, which showcases advanced technologies designed to ensure reliable power delivery.

The APC 230 VAC, 750,100 is a high-performance UPS that offers a robust solution for businesses looking to maintain operational continuity during power disruptions. With a rated output voltage of 230 VAC, this UPS is adept at providing reliable power for various applications, including server rooms, telecommunications, and critical infrastructure.

One of the standout features of the APC 230 VAC, 750,100 is its capacity of 750 VA (volt-amperes), which translates to 600 watts of output power. This capacity ensures that the UPS can support essential equipment even during outages, safeguarding against data loss, equipment damage, and downtime. The design of the unit focuses on maximizing efficiency, ensuring lower energy costs and reduced heat emissions, which is crucial for maintaining optimal operating conditions in IT environments.

The UPS is equipped with advanced battery management technology, which enhances battery life and performance. The system features smart charging capabilities that help prolong battery lifespan by preventing overcharging and optimizing discharge cycles. Additionally, the unit incorporates a user-friendly interface with LCD displays, providing real-time status updates on power conditions, battery health, and load levels.

Another characteristic that sets the APC 230 VAC, 750,100 apart is its compact and ergonomic design, which makes installation straightforward in various environments. With multiple outlets, it allows for the simultaneous connection of multiple devices, ensuring comprehensive protection for critical loads.

Moreover, APC integrates intelligent monitoring software with the UPS, which enables remote management and monitoring. This feature is particularly beneficial for IT administrators, allowing them to track the performance of the UPS and respond swiftly to any issues.

In summary, the APC 230 VAC, 750,100 is an exemplary power protection solution that combines efficient operation, advanced technologies, and user-friendly features. Whether for small businesses or large organizations, this UPS is designed to meet the demands of modern technology, ensuring that power interruptions do not disrupt essential operations. Its innovative design and robust capabilities make it a reliable choice for maintaining the integrity of critical systems.